/generator-error-codes

Generac Generator 1505 Error Code Explained: Meaning, Causes & Fixes

Discover the meaning, common causes, and effective fixes for Generac Generator 1505 error code. Get your generator running smoothly again with these expert troubleshooting tips.

Reviewed by Content Team

Head of Content, D. Gorenko

Updated June, 5

What does the 1505 error code on Generac a Generator mean?

 

What the 1505 Error Code Means on a Generac Generator

 

When you see a 1505 error code on your Generac generator, it means that there is an "RPM Sense Loss" fault. In simple terms, this message is telling you that the generator's engine is not detecting the correct speed (RPM stands for "revolutions per minute"). The generator expects to sense how fast the engine is running, and when it can't, it shuts itself down as a protection. This error can occur whether your generator is serving a home in St Louis or a business in Nashville.

 

What Causes the 1505 Error Code?

 

A 1505 error code is usually tied to starting issues, and it's almost always because the engine won't start. Here's why it might happen:

  • Battery Is Low or Dead: The generator uses an electric starter that gets its power from a battery. If the battery is weak or not charged properly, the engine can't turn over fast enough, causing the RPM sensor to not pick up any signal.
  • Starter Motor Issues: The starter motor cranks the engine so it can begin running. If this part is failing or not getting power, the generator can't start, and you see the code.
  • Loose or Corroded Battery Connections: If the wires on the battery are dirty, loose, or corroded, electricity can't flow well enough to the starter.
  • Bad or Dirty Spark Plugs: Spark plugs ignite the fuel inside the engine. If they're worn out, the engine might not start at all, again causing the sensor to report no movement.
  • Fuel Problems: If there’s no fuel, the wrong type of fuel, or if fuel lines are clogged (sometimes common after long periods without use seen in climates like St Louis and Nashville), the engine will try to start but fail.
  • Broken Flywheel Sensor (RPM Sensor): The RPM sense loss fault can also mean the component that actually detects the engine’s speed isn’t working right, either due to wiring problems or internal damage.

 

What Should You Do If You Get a 1505 Fault?

 

Let’s break down some practical steps you can perform before calling a professional:

  • Check the Battery: Make sure the battery is charged and in good condition. If it’s beyond 3-4 years old, it might be time to replace it.
  • Inspect the Battery Cables: Look for white, green, or brown buildup (corrosion) at the terminals. Tighten any loose connections.
  • Try to Clear the Code: Press “Enter” or “Reset” on your generator’s control panel. Sometimes, it clears the code if the issue was temporary. If the error returns, the problem is still there.
  • Fuel Supply: Check there is adequate fuel, and ensure the fuel shutoff valve is open. Listen for strange sounds or lack of engine turnover when you try to start it.
  • Listen for the Starter: If you don't hear the engine turning over and there’s only a click or nothing at all, battery or starter motor issues are likely.

 

Why Generators in St Louis and Nashville Might Get this Code

 

Cities like St Louis and Nashville experience a range of weather events—including storms, ice, and long stretches without power outages—all of which can cause batteries to lose charge from lack of use or become corroded from moisture. Regular maintenance can help prevent the 1505 fault.

 

How to Prevent the 1505 Code in the Future

 

You can avoid many 1505 errors before they start by doing the following:

  • Keep the Battery Tested and Changed Regularly: Especially important after cold winters or stormy weather in areas like St Louis.
  • Schedule Annual Maintenance: Having the generator examined by a professional once a year is the best way to catch problems early.
  • Run the Generator Monthly: Most generators run self-tests weekly or monthly—make sure yours is set up and actually running these tests.
  • Inspect and Clean Connections: Remove corrosion from battery terminals and make sure all wires are secure.

 

When to Call a Professional

 

If you still see the error or if the generator tries and fails to start (or makes unusual noises), it’s time to call someone who specializes in generator service for further diagnosis. Residents or businesses in St Louis and Nashville can rest assured knowing there are reliable, experienced teams who can get your standby power back on track safely and efficiently.

 

Expert Generator Solutions Await!

Generator issues in St. Louis or Nashville? Our experts provide quick repairs and maintenance to keep you cool. Contact us today!

Request a quote

How to fix the 1505 Error on a Generac Generator?

 

What Causes the 1505 Error on a Generac Generator and How You Can Fix It

 

The 1505 Error on a Generac generator is a common alert that means the engine failed to start after the unit tried several times. This problem is also called an "Overcrank" error. Essentially, your generator attempted to start repeatedly, but for some reason, it could not get going. This error can be caused by several reasons, including battery problems, low fuel, spark plug issues, fuel or air supply troubles, or even a faulty starter motor. Generac generators protect themselves by shutting down and giving you the 1505 code so you know something is stopping it from running. If you are in the St Louis or Nashville area, these are common issues technicians deal with frequently.

 

Basic Precautions When Dealing with Generator Errors

 

Before you try fixing the 1505 error, always put safety first:

  • Turn off the generator and allow it to rest before touching any parts
  • Use insulated gloves and eye protection if you are inspecting the inside
  • Never work around fuel if you smell gas or see leaks—this can be a major safety risk
  • If in doubt, always call an experienced technician, especially in the St Louis or Nashville region

 

Step-by-Step Solutions for Clearing the 1505 Error

 

Here are the most effective steps to resolve a 1505 error, explained simply and clearly:

  • Check the Battery First
    Generators rely on a battery to start the engine—if it’s weak, dead, or the connections are loose, your generator can’t crank. Inspect the battery for corrosion, tightness of the cables, and make sure it’s charged. If it’s low, charge it fully; if it’s old (over 3-5 years), it likely needs replacing. This is a key step whether you’re in St Louis or Nashville, since battery failure is the most common cause.
  • Inspect Fuel Levels and Fuel Valve
    Verify that your generator has enough fuel. If it’s natural gas or propane, ensure that the supply is open and the tank or gas line is not empty. Sometimes, simply opening the valve fully or filling the tank can resolve the problem quickly.
  • Examine the Spark Plugs
    A dirty, damaged, or loose spark plug prevents the engine from igniting. Remove the spark plug using a socket wrench and check for wear, carbon buildup, or gap issues. Clean or replace as needed. Always reinstall them gently to avoid damaging the threads.
  • Review Air and Fuel Filters
    Clogged air or fuel filters make it hard for the engine to breathe or get fuel, causing starting problems and the 1505 error. Check both filters; if they are dirty or haven’t been replaced in a while, put in new ones.
  • Examine the Starter Motor and Cables
    The starter motor cranks the engine. Listen for clicking or grinding. If you hear nothing at all, ensure all connections are tight and not corroded. If the motor is faulty, it requires professional replacement—Hoffman Brothers can assist in both St Louis and Nashville.
  • Check the Generator Control Panel
    Look at the control panel display for any other warning or error codes. Clear the 1505 code by pressing "OFF," waiting a few seconds, then pressing "ENTER" or "RESET," and finally "AUTO" mode. This cycle can sometimes reset the entire system after a minor glitch.
  • Inspect for Additional Faults or Leaks
    Look for visible fuel, oil, or coolant leaks. Any leak will prevent starting, and these need attention before starting again.

 

When to Call a Professional

 

If you have tried these steps and the generator still displays the 1505 error, it’s time to call a professional. Serious issues like bad solenoids, a malfunctioning electronic control module, or damaged starter systems can’t be fixed without expertise and the proper tools. Residents of St Louis or Nashville often rely on local service teams with the right experience to get standby generators back online quickly and safely. If you don’t feel confident or spot any concerning signs like strong fuel smell, unusual noises, or persistent failure, always choose safety and contact a licensed technician.

 

How to Prevent Generator Overcrank Errors in the Future

 

Routine maintenance is the best way to avoid seeing the 1505 error again. Make sure to:

  • Test your generator monthly; let it run for about 10–15 minutes
  • Keep the battery charged and replaced at manufacturer-recommended intervals
  • Replace air and fuel filters annually or per your owner’s manual
  • Keep fuel tanks clean and above minimal level
  • Schedule annual checkups with experienced teams in St Louis or Nashville

With attention to these steps, you can clear the 1505 Error on your Generac generator and help ensure reliable backup power for your home or business.

Areas Of Expertise

We treat our people as our top priority so they'll treat you the same way. 100% Satisfaction, Every Time!

Air Conditioning

Providing air conditioning repairs, installation and maintenance for St Louis, MO and Nashville, TN. During the hot summers, call Hoffmann Brothers for all your AC repairs, replacement, and tuneup needs.

Electrical Repair

Hoffmann Brothers offers residential and commercial electrical services for St Louis homes and businesses. Lighting, outlets, panels, whole house fans, generators, and more. Call our licensed electricians today!

Heating Services

Need a furnace repair in St Louis or Nashville? Hoffmann Brothers can handle all your heating repairs, no matter the brand, including ductless mini-split systems. We also proudly offer heating system installations, and ongoing maintenance services.

Appliances

Hoffmann Brothers offers appliance repair services throughout St Louis, MO! Our experienced technicians are trained to work on all major brands of most home appliances including Dishwashers, Refrigerators & Freezers, Washing Machines & Dryers, and Ovens.

Plumbing Services

Hoffmann Brothers is your experienced Plumbing Company service both St Louis and Nashville. We offer plumbing repairs and installations, along with drain and sewer solutions.

Commercial Services

Do you need Mechanical or Commercial services for your St Louis or Nashville area business? We offer HVAC, Plumbing, Electrical (St Louis only), Indoor Air Quality, and more.

Water Heaters

Hoffmann Brothers is your professional water heater contractors for both Nashville, TN and St Louis, MO. We provide hot water heater installation, repair, and maintenance for both standard and tankless systems.

Drains & Sewers

Hoffmann Brothers is your Nashville and St Louis area drain Plumber. We provide drain cleaning and clearing and much more. Trust our drain experts to fix your clogged sink or toilet quickly and efficiently.

What could be causing the 1505 error code on a Generac Generator?

 

What Causes a 1505 Error Code on a Generac Generator?

 

When a Generac generator displays the 1505 error code, it means there is a problem with the generator's engine speed. Specifically, this code is labeled as "RPM Sense Loss," which means the system has detected that the engine is not running at the expected speed or is not running at all when instructed to do so. In simple terms, the generator thinks the engine has stopped, slowed down, or failed to start, even though it tried to start or was already running.

This error frequently shows up on standby generators installed in homes and businesses throughout St Louis and Nashville, where severe weather or outages make backup power crucial.

 

Understanding "RPM Sense Loss"

 

"RPM" means "revolutions per minute," which is how many times the engine's crankshaft spins in one minute. The generator has sensors that monitor whether the engine is spinning at normal speed. If the sensor detects that the engine isn't spinning fast enough, stopped spinning, or never started, it sends a signal to the control board, which then triggers the 1505 code and shuts down the generator to protect it.

 

Common Causes of the 1505 Error Code

 

Several issues can trigger RPM Sense Loss on Generac generators commonly found in St Louis and Nashville:

  • Low Battery Voltage: The battery supplies power to start the generator. If the battery is weak or dead, the generator may crank slowly or not at all, leading the system to think the engine isn’t running as expected.
  • Faulty or Loose Battery Connections: Corroded, dirty, or loose battery cables can keep power from reaching the starter motor, so the engine never turns over, triggering the code.
  • Failed Starter Motor: If the starter motor is worn out or faulty, it can’t spin the engine fast enough (or at all), so the generator senses the wrong RPM.
  • Bad RPM Sensor (Magnetic Pickup Sensor): The magnetic pickup sensor tells the controller how fast the engine is spinning. If the sensor or its wiring is damaged or disconnected, the system can’t “see” the engine’s speed.
  • Blocked Fuel Supply: Any blockage in the fuel line, fuel filter, or carburetor can keep fuel from reaching the engine, so it starts and dies quickly, or never starts, making it look to the controller like “RPM Sense Loss.”
  • Engine or Control Board Wiring Problems: Broken, frayed, or disconnected wires between key components can disrupt the signals needed to start and monitor the engine.
  • Low Oil or Safety Shutdown: If oil level is too low or another safety feature (like temperature sensors) is triggered, the control board might shut the engine down for protection, even if it was running a moment ago. This can show up as an RPM Sense Loss since the engine stopped unexpectedly.
  • Blown Fuses or Relay Issues: A blown fuse or stuck relay in the starter circuit can prevent the engine from cranking, creating an RPM loss scenario.

 

How the 1505 Error Appears in Different Situations

 

Generators in St Louis usually work overtime during summer storms and winter freezes—conditions that test batteries and starter systems. Extended inactivity, which is typical in regions like Nashville where outages are less common, can allow batteries to deteriorate unseen, only showing trouble when an outage finally requires backup power. In both regions, dramatic temperature changes and humidity affect electrical connections and can accelerate corrosion, creating the right conditions for an unexpected 1505 code.

 

Summary

 

The 1505 error code on a Generac generator means the system can’t sense that the engine is spinning at the right speed. This usually happens because of battery problems, starter faults, RPM or wiring issues, or fuel delivery problems. Generators across St Louis and Nashville deal with common regional factors like weather, long periods of inactivity, and electrical wear-and-tear, which can all lead to this code appearing. If you see a 1505 RPM sense loss on your generator’s display, it’s important to know it generally points to issues where the engine can’t start or stay running, or when the system isn’t getting the right signals about engine speed.

SERVING

St. Louis & Nashville Areas

Brentwood, MO
1025 Hanley Industrial
Brentwood, MO 63144

Nashville, TN
45 Willow St.
Nashville, TN 37210

Call Our St. Louis Office

Call Our Nashville Office

Nashville Location

(615) 515-3015

Read More

Kohler Generator Code 21 Error Code Explained: Meaning, Causes & Fixes

Discover what Kohler Generator Code 21 means, its common causes, and how to fix it. Get quick troubleshooting tips to resolve this error and keep your generator running smoothly.

Kohler Generator Code 24 Error Code Explained: Meaning, Causes & Fixes

Discover what Kohler Generator Code 24 means, common causes behind this error, and step-by-step solutions to fix it. Quickly troubleshoot your generator with our expert guide.

Kohler Generator Accy PwrOver Warning Error Code Explained: Meaning, Causes & Fixes

Discover what the Kohler Generator "Accy PwrOver Warning" error code means, its common causes, and how to fix it. Get clear, step-by-step solutions to keep your generator running smoothly.

Cummins Generator SPN 175 FMI 3 Error Code Explained: Meaning, Causes & Fixes

Discover the meaning, common causes, and solutions for the Cummins Generator SPN 175 FMI 3 error code. Learn how to diagnose and fix this issue to keep your generator running smoothly.

Kohler Generator Code 23 Error Code Explained: Meaning, Causes & Fixes

Discover what Kohler Generator Code 23 means, common causes behind the error, and effective solutions to fix it. Get your generator running smoothly with these expert tips.

Cummins Generator SPN 284 FMI 4 Error Code Explained: Meaning, Causes & Fixes

Discover the meaning, common causes, and solutions for Cummins Generator SPN 284 FMI 4 error code. Quickly troubleshoot and resolve this generator issue with our expert guide.