Discover what the Kohler Generator OU error code means, its common causes, and quick fixes. Get your generator running smoothly with expert troubleshooting tips.

Head of Content, D. Gorenko
Updated June, 5
When a generator displays the "OU" error code, it means that the unit has detected an Over-Voltage or Under-Voltage situation. In simple terms, this error message tells you that the electricity coming from your generator is either too high (overvoltage) or too low (undervoltage) compared to what’s considered safe for your home or business. Both scenarios can harm your appliances, electronics, or the generator itself.
Over-voltage happens when the generator produces more electrical power than it should. Imagine a water hose: if you turn the tap too high, the water pressure might burst the hose. Similarly, if your generator delivers too much voltage, it can damage electronics and wiring in your property.
Under-voltage is the opposite, where your generator isn’t producing enough voltage. Think of it as not turning the tap enough; appliances and equipment won’t get what they need to function properly. Your lights might dim, and sensitive electronics could turn off or malfunction. Both conditions are especially important to recognize and address in areas like St Louis or Nashville, where reliable power protects homes and businesses from expensive damages during storms or outages.
The "OU" error code is a built-in safety feature. Generators use an automatic monitoring system called an AVR (Automatic Voltage Regulator). The AVR checks the voltage output all the time. If something goes wrong—like an internal part failing, a loose wire, a faulty AVR, or if the engine isn’t running properly—the generator can’t maintain the right voltage level. When this happens, the control panel gives you the "OU" error message and might automatically shut off the generator to prevent further issues.
Other possible causes include:
If your generator shows the "OU" error code, the safest step is to turn off the generator and disconnect what it is powering. Here’s what you can do:
If the error doesn’t clear after these checks, you should not continue using the generator until the problem is fixed. Trying to use it with an OU error can cause safety hazards or permanent damage.
Some generator issues are simple, but if you’re not sure about electrical terms or you don’t have technical experience, it’s important to get help from professionals. For homeowners and businesses in St Louis and Nashville, specialists familiar with local power systems and weather patterns can diagnose and repair voltage errors effectively, ensuring your generator is safe and reliable for future outages.
They will check deep internal parts, use special diagnostic tools to read error codes, and make sure your generator's automatic voltage regulator and all other safety systems are working as they should.
To prevent OU or voltage error codes, schedule regular generator maintenance. Clean or replace filters, use fresh fuel, and run the generator occasionally—even when you don’t need it. Maintain a clear record of what’s plugged in during operation. This is particularly important for households and commercial buildings in weather-impacted locations like St Louis or the severe weather seasons seen in Nashville.
By staying proactive, you help ensure your generator is ready in any emergency, limiting downtime and keeping your property safe from unexpected electrical issues.

Generator issues in St. Louis or Nashville? Our experts provide quick repairs and maintenance to keep you cool. Contact us today!
Request a quote
The OU Error on a Kohler generator stands for "Overvoltage Underfrequency." This error appears on the generator’s control panel when the system detects that the voltage is too high, while the frequency (measured in Hertz) is too low. This combination is not normal and signals that there’s a problem within the generator’s electrical output or control systems. If you’re in St Louis or Nashville, where stable standby power is critical during severe weather, quick attention to this error keeps your home or business protected.
With these steps, most homeowners or business owners can address basic issues that cause the OU error. For anything beyond basic checks—such as voltage regulator, control board, governor, or sensor problems—contact a licensed electrician or a trusted technical company in St Louis or Nashville with generator experience to make sure your Kohler unit remains reliable and safe during outages.
We treat our people as our top priority so they'll treat you the same way. 100% Satisfaction, Every Time!
Providing air conditioning repairs, installation and maintenance for St Louis, MO and Nashville, TN. During the hot summers, call Hoffmann Brothers for all your AC repairs, replacement, and tuneup needs.
Hoffmann Brothers offers residential and commercial electrical services for St Louis homes and businesses. Lighting, outlets, panels, whole house fans, generators, and more. Call our licensed electricians today!
Need a furnace repair in St Louis or Nashville? Hoffmann Brothers can handle all your heating repairs, no matter the brand, including ductless mini-split systems. We also proudly offer heating system installations, and ongoing maintenance services.
Hoffmann Brothers offers appliance repair services throughout St Louis, MO! Our experienced technicians are trained to work on all major brands of most home appliances including Dishwashers, Refrigerators & Freezers, Washing Machines & Dryers, and Ovens.
Hoffmann Brothers is your experienced Plumbing Company service both St Louis and Nashville. We offer plumbing repairs and installations, along with drain and sewer solutions.
Do you need Mechanical or Commercial services for your St Louis or Nashville area business? We offer HVAC, Plumbing, Electrical (St Louis only), Indoor Air Quality, and more.
Hoffmann Brothers is your professional water heater contractors for both Nashville, TN and St Louis, MO. We provide hot water heater installation, repair, and maintenance for both standard and tankless systems.
Hoffmann Brothers is your Nashville and St Louis area drain Plumber. We provide drain cleaning and clearing and much more. Trust our drain experts to fix your clogged sink or toilet quickly and efficiently.
When your Kohler generator displays the OU error code, it stands for "Over Crank" or "Overcrank Shutdown." In simple terms, this means the generator tried several times to start up, but it couldn’t actually begin running in the correct way within the time allowed. Generators like those often installed in both St Louis and Nashville homes or businesses are programmed to protect themselves if something goes wrong during start-up, so they shut down rather than continue unsuccessfully trying to start—this is when they give you the OU code.
There can be several causes behind an OU error appearing on your generator display:
Both St Louis and Nashville experience temperature extremes—hot, humid summers and cold winters. Extreme cold can thicken oil and slow batteries, while high summer humidity can affect sensitive electronics and battery health. All of these conditions can make it harder for your generator to fire up, making the OU code more likely if regular maintenance or testing isn’t performed.
If your Kohler generator in St Louis or Nashville shows the OU error, the cause is usually related to fuel problems, battery health, engine condition, starter motor performance, oil levels, electrical circuitry, or the ignition system. Essentially, anything that makes it difficult or impossible for the generator’s engine to start after several attempts can result in the OU (Overcrank) shutdown. The generator takes these precautions to protect itself from damage if something isn’t right during startup.
SERVING
Brentwood, MO
1025 Hanley Industrial
Brentwood, MO 63144
Nashville, TN
45 Willow St.
Nashville, TN 37210

St Louis Location
(314) 664-3011
St Louis Location
1025 Hanley Industrial Brentwood, MO 63144
Nashville Location
(615) 515-3015
Nashville Location
45 Willow St Nashville, TN 37210
Discover what Kohler Generator Code 21 means, its common causes, and how to fix it. Get quick troubleshooting tips to resolve this error and keep your generator running smoothly.
Discover what Kohler Generator Code 24 means, common causes behind this error, and step-by-step solutions to fix it. Quickly troubleshoot your generator with our expert guide.
Discover what the Kohler Generator "Accy PwrOver Warning" error code means, its common causes, and how to fix it. Get clear, step-by-step solutions to keep your generator running smoothly.
Discover the meaning, common causes, and solutions for the Cummins Generator SPN 175 FMI 3 error code. Learn how to diagnose and fix this issue to keep your generator running smoothly.
Discover what Kohler Generator Code 23 means, common causes behind the error, and effective solutions to fix it. Get your generator running smoothly with these expert tips.
Discover the meaning, common causes, and solutions for Cummins Generator SPN 284 FMI 4 error code. Quickly troubleshoot and resolve this generator issue with our expert guide.