Discover what Kohler Generator Code 24 means, common causes behind this error, and step-by-step solutions to fix it. Quickly troubleshoot your generator with our expert guide.

Head of Content, D. Gorenko
Updated June, 5
When your generator displays error Code 24, it means there is an issue known as a "Loss of Speed Sensing" or "RPM Sensor Fault." In simple words, the generator’s system cannot properly detect or read the engine's speed (measured in RPM, or revolutions per minute). This problem causes the safety computers inside the generator to shut it down or prevent it from running, to avoid possible damage. This error is common in both standby and portable generators and signals that a key component which monitors the engine's speed has either failed, come loose, or is getting incorrect information.
There are several reasons why a generator in St Louis homes or businesses, as well as those in Nashville, might display this error:
If your generator in St Louis or Nashville throws a Code 24 error, it will either not run at all or shut off shortly after starting. The system does this for your safety—to prevent engine damage, generator overheating, or power delivery issues to your building. It also means your backup power source may not be available during an outage, so prompt attention is very important.
Here’s what you should do if your generator is showing this code:
When a skilled technician is called for a Code 24 error—whether to a residential home in St Louis or a business in Nashville—they usually follow these steps:
Error Code 24 on your generator is a safety alert telling you the system cannot track how fast the engine is spinning—often due to a sensor or wiring issue. Don’t ignore this code. If you see it, pause operation and contact an expert with experience in generator diagnosis and repair. For anyone in the St Louis or Nashville areas, having your generator regularly maintained will both prevent and quickly resolve this sort of error, protecting your power supply and equipment for the future.

Generator issues in St. Louis or Nashville? Our experts provide quick repairs and maintenance to keep you cool. Contact us today!
Request a quote
Kohler generators are reliable backup power solutions, but like any technology, they can sometimes display error codes that indicate an issue. The Code 24 error on Kohler generators specifically means "Overcrank." This happens when your generator tries to start up but fails multiple times in a row. Fixing this issue involves checking fuel, battery, wiring, and engine components—most of which are simple steps you can do yourself or with basic guidance. If you’re located in St Louis or Nashville, Hoffman Brothers technicians are experienced in safe, comprehensive generator troubleshooting and repair, ensuring your generator is ready when you need it most.
When your Kohler generator tries to start (cranking the engine), it expects to fire up within a certain number of attempts. “Overcrank” means your generator’s engine is turning over but not running—usually after the controller tried three times and shut down to avoid damage or draining the battery. Fixing Code 24 involves discovering why your generator won’t start.
If your Kohler generator still displays Code 24 after these checks—especially if you notice extended cranking, battery drain, or if the engine seems unwilling to start—contact a qualified technician. Specialized diagnostic tools may be needed to evaluate the starter motor, solenoid, engine sensors, control board, or other complex parts. Residents and businesses in St Louis and Nashville commonly rely on professional help for wiring, electronics, or warranty-related service.
Following these steps resolves the majority of Kohler generator Code 24 errors. By methodically checking fuel, battery, ignition, air, and oil systems—and knowing when to call a professional—you’ll keep your backup power reliable no matter what.
We treat our people as our top priority so they'll treat you the same way. 100% Satisfaction, Every Time!
Providing air conditioning repairs, installation and maintenance for St Louis, MO and Nashville, TN. During the hot summers, call Hoffmann Brothers for all your AC repairs, replacement, and tuneup needs.
Hoffmann Brothers offers residential and commercial electrical services for St Louis homes and businesses. Lighting, outlets, panels, whole house fans, generators, and more. Call our licensed electricians today!
Need a furnace repair in St Louis or Nashville? Hoffmann Brothers can handle all your heating repairs, no matter the brand, including ductless mini-split systems. We also proudly offer heating system installations, and ongoing maintenance services.
Hoffmann Brothers offers appliance repair services throughout St Louis, MO! Our experienced technicians are trained to work on all major brands of most home appliances including Dishwashers, Refrigerators & Freezers, Washing Machines & Dryers, and Ovens.
Hoffmann Brothers is your experienced Plumbing Company service both St Louis and Nashville. We offer plumbing repairs and installations, along with drain and sewer solutions.
Do you need Mechanical or Commercial services for your St Louis or Nashville area business? We offer HVAC, Plumbing, Electrical (St Louis only), Indoor Air Quality, and more.
Hoffmann Brothers is your professional water heater contractors for both Nashville, TN and St Louis, MO. We provide hot water heater installation, repair, and maintenance for both standard and tankless systems.
Hoffmann Brothers is your Nashville and St Louis area drain Plumber. We provide drain cleaning and clearing and much more. Trust our drain experts to fix your clogged sink or toilet quickly and efficiently.
A Code 24 error on a Kohler generator means that the generator’s speed is too high. In simpler terms, the engine is spinning faster than it should be during operation. This is commonly called an “Overspeed” condition. For most homeowners and business owners in St Louis or Nashville, this error code is the generator’s way of protecting itself from damage by shutting down or preventing operation until the issue is addressed.
What “Overspeed” means and why it happens
When we talk about speed in generators, we really mean the number of revolutions the engine makes per minute (RPM). Generators are designed to work best at a set RPM that matches the electrical output needed for your home or business in locations like St Louis or Nashville. If the engine spins too fast, it creates electrical power that is outside the safe range for your appliances and electrical systems. Kohler generators have sensors (often called RPM or speed sensors) that constantly measure this, and if they detect the RPM is too high—usually above 66-68 Hertz instead of the normal 60 Hertz—they trigger a Code 24 and shut things down.
Common reasons a Kohler generator gets a Code 24 error
Why this error matters for your setup
A Code 24 isn’t just a nuisance—it’s a warning that running the generator in its current state could result in electrical damage to your home or business in St Louis or Nashville. Overspeed can damage sensitive appliances, generator internals, and even lead to costly outages during extreme weather events. Kohler includes these safeguards so that your generator doesn’t harm itself or the building it’s meant to protect.
If you see a Code 24, the system is telling you it’s detected a risk, often because of a mechanical, electrical, or sensor-related fault, and immediate attention from a generator specialist is needed to keep your backup power reliable.
SERVING
Brentwood, MO
1025 Hanley Industrial
Brentwood, MO 63144
Nashville, TN
45 Willow St.
Nashville, TN 37210

St Louis Location
(314) 664-3011
St Louis Location
1025 Hanley Industrial Brentwood, MO 63144
Nashville Location
(615) 515-3015
Nashville Location
45 Willow St Nashville, TN 37210
Discover what Kohler Generator Code 21 means, its common causes, and how to fix it. Get quick troubleshooting tips to resolve this error and keep your generator running smoothly.
Discover what Kohler Generator Code 24 means, common causes behind this error, and step-by-step solutions to fix it. Quickly troubleshoot your generator with our expert guide.
Discover what the Kohler Generator "Accy PwrOver Warning" error code means, its common causes, and how to fix it. Get clear, step-by-step solutions to keep your generator running smoothly.
Discover the meaning, common causes, and solutions for the Cummins Generator SPN 175 FMI 3 error code. Learn how to diagnose and fix this issue to keep your generator running smoothly.
Discover what Kohler Generator Code 23 means, common causes behind the error, and effective solutions to fix it. Get your generator running smoothly with these expert tips.
Discover the meaning, common causes, and solutions for Cummins Generator SPN 284 FMI 4 error code. Quickly troubleshoot and resolve this generator issue with our expert guide.