Kohler Generator LOP Error Code Explained: Meaning, Causes & Fixes

Discover what the Kohler Generator LOP error code means, its common causes, and how to fix it. Get quick troubleshooting tips to restore your generator’s performance.

Reviewed by Content Team

Head of Content, D. Gorenko

Updated June, 5

What does the LOP error code on Kohler a Generator mean?

 

Understanding the LOP Error Code on a Generator

 

The LOP error code on a generator stands for "Low Oil Pressure." When your generator displays the LOP error code, it means that the machine has detected that the oil pressure inside the engine is below a safe or recommended level. Oil pressure is crucial for keeping the engine's moving parts lubricated and protected from damage. If oil pressure drops too low, it can cause the engine to run poorly, shut down, or even be permanently damaged. This safety feature is common in both home and commercial generators in areas like St Louis and Nashville, where generators are often used during storms and outages.

 

What Causes the LOP Error Code?

 

Generators in residential and commercial buildings across St Louis and Nashville may display the LOP error for several reasons:

  • Low Oil Level: If the generator’s engine is running with not enough oil, pressure drops and the error code appears. Just like a car, a generator needs the right amount of oil not just to run, but to prevent friction and overheating.
  • Dirty or Old Oil: Oil breaks down over time and collects dirt, which can clog the passages inside your engine, reducing pressure and triggering the LOP warning.
  • Faulty Oil Pressure Sensor: Sometimes, the issue is not with the oil itself, but with the sensor reading the pressure. These sensors can fail or give incorrect readings, leading to false alarms.
  • Oil Leaks: If there is a leak in the generator—whether from a gasket, a loose fitting, or a cracked component—the oil level will drop, causing low pressure and the LOP message.
  • Pump or Engine Problems: A failing oil pump or internal engine problem may prevent oil from circulating correctly, dropping the pressure even if the oil level is correct.

 

Why Is Monitoring Oil Pressure Important?

 

Maintaining oil pressure is critically important, especially in climates like those in St Louis and Nashville, where temperature changes and frequent use can stress a generator. If oil pressure falls below safe thresholds, the internal parts of the engine can rub against each other and wear out, break, or even seize up. That’s why generators are designed to shut down automatically when the LOP code appears—to protect the engine from expensive and often irreversible damage.

 

What Should You Do If Your Generator Shows the LOP Error?

 

If you see the LOP error code on your generator, here are steps you should take:

  • Turn Off the Generator: Immediately power down your generator to prevent any additional damage. Avoid restarting it until you’ve checked the oil level.
  • Check the Oil Level: Use the oil dipstick (usually located on the side of the engine) to see if the oil is at the right level. If it’s low, add the appropriate type and amount of oil as specified in your owner’s manual.
  • Look for Leaks: Inspect around the engine for any signs of oil leaks, pooling, or drips under the generator.
  • Check Oil Quality: If the oil looks dirty, thick, or sludgy, it needs to be replaced. Fresh, clean oil should be golden or amber in color.
  • Reset the Error Code: After addressing the oil issue, some generators will automatically reset once restarted. Others may require you to manually clear the error by following the instructions in your service manual.
  • Contact a Professional: If you’ve added oil and the code persists, or if you’re unsure about the cause, it’s best to call a trusted generator specialist. This ensures your generator is safe for use and protects your investment. In areas like St Louis and Nashville, local residential and commercial service providers can check more complex issues and perform repairs or maintenance.

 

Preventing LOP Errors in the Future

 

Routine maintenance is key to preventing LOP errors. This is especially important if you rely on backup power during storm seasons or power outages in St Louis and Nashville. Helpful tips include:

  • Regularly checking and topping off oil levels before and after each use.
  • Changing oil as recommended by the manufacturer—usually every 50-100 hours of operation.
  • Scheduling annual professional inspections to look for potential problems like leaks, worn pumps, or faulty sensors.
  • Storing the generator on level ground to ensure accurate oil readings.

Proper care and fast attention to errors ensure your unit is ready when you need it most and can extend its lifespan whether it’s serving a family home or critical business infrastructure in St Louis or Nashville. In summary, the LOP error is a warning meant to keep your generator—and your property—safe from engine failure. Responding quickly and following best maintenance practices will minimize disruption and costly repairs.

Expert Generator Solutions Await!

Generator issues in St. Louis or Nashville? Our experts provide quick repairs and maintenance to keep you cool. Contact us today!

Request a quote

How to fix the LOP Error on a Kohler Generator?

 

Understanding and Fixing the LOP Error on a Kohler Generator

 

The LOP error on a Kohler generator stands for "Low Oil Pressure." This means the generator's internal sensors have detected that the oil pressure is below the safe operating range. Low oil pressure can lead to severe engine damage, so the generator automatically shuts down or refuses to start until the issue is resolved. If you're in St Louis or Nashville, proper diagnosis and resolution of this error is crucial to keep your home or business protected during power outages.

 

Immediate Steps to Take When You See an LOP Error

 

  • Turn Off the Generator: As soon as you see the LOP error, switch off your Kohler generator. Avoid trying to restart it until you have checked and corrected the problem. Running the engine with low oil pressure can cause permanent damage.

 

Checking Oil Level and Condition

 

  • Locate the Oil Dipstick: Open the generator’s access panel. Find the oil dipstick—it looks similar to those in cars and usually has a bright colored or labeled handle.
  • Check the Oil Level: Pull out the dipstick, wipe it clean, insert it all the way, then pull it out again. Look at the oil on the dipstick to see where it reaches relative to the “Full” and “Add” marks. If it’s low, add manufacturer-recommended oil until you reach the proper level.
  • Inspect Oil Quality: Good engine oil should look amber or brownish, but not milky, gritty, or sludge-like. If the oil is dirty or contaminated, perform a complete oil change following Kohler’s guidelines.

 

Checking and Replacing the Oil Filter

 

  • Locate the Oil Filter: Refer to your generator's manual to find the oil filter location. A clogged or dirty oil filter can cause low oil pressure.
  • Replace the Oil Filter if Necessary: If the filter appears old or dirty, replace it with a new one that matches Kohler’s specifications for your particular model.

 

Inspecting for Oil Leaks and Blockages

 

  • Look Under and Around the Generator: Check for visible oil puddles, wet spots, or stains beneath the generator or on the unit. Oil leaks should be fixed promptly to avoid ongoing loss of oil (and pressure).
  • Check Oil Lines and Gaskets: Look closely at hoses, fittings, and gasketed areas for signs of oil seepage or damage.
  • Clear Blockages: Sometimes oil passages inside the engine can become blocked with sludge or debris. If there’s evidence of contamination and you have experience, you can try flushing the system, but in most cases, calling a qualified technician from St Louis or Nashville is the safest option for deeper internal issues.

 

Checking the Oil Pressure Sensor or Switch

 

  • Locate the Oil Pressure Sensor: This is a small electronic device screwed into the engine block and wired into the generator’s controls. It monitors the oil pressure and triggers the LOP warning if pressure is too low.
  • Inspect for Loose or Damaged Wires: Make sure the sensor’s connectors are tightly in place and not corroded or broken.
  • Test or Replace the Sensor: Sometimes the sensor itself fails, even if oil level and pressure are fine. If all other steps are good and the error persists, the sensor may need replacement.

 

Restarting the Generator After Fixes

 

  • After refilling oil, replacing filters, correcting leaks, and checking the sensor, reset the generator’s controller if needed (often this involves holding the “Reset” or “Off/Reset” button for a few seconds, but check your Kohler manual for specifics).
  • Try restarting the generator. Watch for the LOP error. If it clears and the unit runs smoothly, monitor for several minutes to confirm the problem is solved.
  • If the LOP fault shows up again, do not force the unit to run—this can indicate a deeper engine issue (such as an oil pump failure or a worn-out internal engine part). At this point, it’s essential to contact a generator specialist in St Louis or Nashville.

 

Regular Maintenance to Prevent LOP Errors

 

  • Change oil and filter at intervals suggested by Kohler—often every 100-200 hours of use or annually, whichever comes first.
  • Inspect for leaks and check oil levels monthly if your generator is used for standby power.
  • Make sure your generator is positioned on a level surface; if it’s tilted, oil may not flow correctly and could cause low pressure readings.
  • If in doubt, or if you’re not comfortable with maintenance, schedule professional service in St Louis or Nashville to keep the generator running reliably.

 

The LOP error on a Kohler generator is a safety mechanism to prevent engine damage. Most often, it's caused by low oil level, dirty oil, a failing sensor, or an oil leak. Once you check and correct these issues, the generator should reset. If not, expert help from a local technician is the safest way to prevent further problems and keep your backup power system dependable.

Areas Of Expertise

We treat our people as our top priority so they'll treat you the same way. 100% Satisfaction, Every Time!

Air Conditioning

Providing air conditioning repairs, installation and maintenance for St Louis, MO and Nashville, TN. During the hot summers, call Hoffmann Brothers for all your AC repairs, replacement, and tuneup needs.

Electrical Repair

Hoffmann Brothers offers residential and commercial electrical services for St Louis homes and businesses. Lighting, outlets, panels, whole house fans, generators, and more. Call our licensed electricians today!

Heating Services

Need a furnace repair in St Louis or Nashville? Hoffmann Brothers can handle all your heating repairs, no matter the brand, including ductless mini-split systems. We also proudly offer heating system installations, and ongoing maintenance services.

Appliances

Hoffmann Brothers offers appliance repair services throughout St Louis, MO! Our experienced technicians are trained to work on all major brands of most home appliances including Dishwashers, Refrigerators & Freezers, Washing Machines & Dryers, and Ovens.

Plumbing Services

Hoffmann Brothers is your experienced Plumbing Company service both St Louis and Nashville. We offer plumbing repairs and installations, along with drain and sewer solutions.

Commercial Services

Do you need Mechanical or Commercial services for your St Louis or Nashville area business? We offer HVAC, Plumbing, Electrical (St Louis only), Indoor Air Quality, and more.

Water Heaters

Hoffmann Brothers is your professional water heater contractors for both Nashville, TN and St Louis, MO. We provide hot water heater installation, repair, and maintenance for both standard and tankless systems.

Drains & Sewers

Hoffmann Brothers is your Nashville and St Louis area drain Plumber. We provide drain cleaning and clearing and much more. Trust our drain experts to fix your clogged sink or toilet quickly and efficiently.

What could be causing the LOP error code on a Kohler Generator?

 

Understanding the LOP Error Code on a Kohler Generator

 

When a Kohler generator displays the “LOP” error code, it stands for “Low Oil Pressure.” This warning means your generator has sensed that its oil pressure has dropped below the safe threshold needed to properly lubricate and protect the engine. At its core, the LOP code is a built-in safeguard: it protects your equipment from severe engine damage by either shutting down the engine or preventing it from starting until the issue is resolved. Both home and business owners in St Louis and Nashville commonly see LOP codes during times of extended generator use, seasonal maintenance lapses, or after an oil change.

 

What Causes Low Oil Pressure in Kohler Generators?

 

Low oil pressure, which triggers the LOP alert, happens when the oil inside your generator’s engine isn’t circulating properly. Since oil lubricates moving parts and keeps the engine cool, a drop in pressure can lead to overheating and rapid wear. Here is a comprehensive look at potential causes:

  • Low Oil Level: If the oil in the generator’s crankcase falls below the required level, the system can’t generate enough pressure to circulate oil through the engine. This is the simplest and most common reason for an LOP code.
  • Oil Leaks: Any dripping or pooling oil beneath the generator or on engine components can lower the amount of available oil, again resulting in insufficient pressure.
  • Incorrect Oil Type or Viscosity: Each engine is designed for a particular oil grade (thickness) and type. If oil with the wrong viscosity is used—too thick or too thin—it may not properly flow at different temperatures, particularly in varying climates like those experienced around St Louis and Nashville. This can prevent consistent pressure.
  • Dirty or Old Oil: Oil that is overdue for replacement can contain contaminants or become thick and sludgy, restricting its flow. Restricted oil flow causes a drop in oil pressure and can bring up the LOP fault.
  • Faulty Oil Filter: If the oil filter gets clogged, oil circulation can be severely reduced. The engine’s sensors will then detect low oil pressure and trigger the LOP code.
  • Problems with the Oil Pressure Sensor: Sometimes, the LOP code appears even when the engine oil system is healthy. A malfunctioning oil pressure sensor or its wiring might send the wrong signal to the control panel.
  • Mechanical Engine Issues: Issues inside the engine, such as worn-out bearings or a failing oil pump, can physically stop the oil from building up adequate pressure. Though less common, these mechanical failures are serious and require professional evaluation, a service that’s frequently called for by homeowners and businesses in Nashville and St Louis.

 

External Factors and Unique Considerations

 

Certain conditions can make your generator more likely to display an LOP code. For generators installed outdoors in areas like St Louis, seasonal swings from hot, humid summers to freezing winters affect how oil flows and how quickly it breaks down. In Nashville, humidity and occasional severe storms can similarly impact generator operation, sometimes accelerating oil breakdown or contaminant buildup. If your generator runs for extended periods during a neighborhood blackout, the engine heats up, and oil pressure can be affected if the oil isn’t topped up or recently changed.

 

Why the LOP Code Should Never Be Ignored

 

Ignoring an LOP code means running your engine with inadequate lubrication. This could quickly lead to severe engine damage—such as scored pistons, damaged crankshafts, and even complete engine failure—resulting in high repair costs and loss of backup power. Homeowners and facility managers in both St Louis and Nashville are advised to treat this code as urgent, regardless of outdoor conditions, generator age, or brand model.

 

Summary of Key Causes of LOP Code

 

  • Oil level too low
  • Oil leaks (visible drips or unexplained oil loss)
  • Old, dirty, or incorrect type/viscosity of oil
  • Clogged oil filter preventing proper oil flow
  • Malfunctioning oil pressure sensor or wiring
  • Internal mechanical failures such as a worn oil pump or engine parts

If you see the LOP error code on your Kohler generator in St Louis or Nashville, it means your system has identified a critical issue with oil circulation or pressure, safeguarding your equipment from likely engine damage. Understanding these potential causes will help you respond quickly and keep your generator safe and reliable.

SERVING

St. Louis & Nashville Areas

Brentwood, MO
1025 Hanley Industrial
Brentwood, MO 63144

Nashville, TN
45 Willow St.
Nashville, TN 37210

Call Our St. Louis Office

Call Our Nashville Office

Nashville Location

(615) 515-3015

Read More

Kohler Generator Code 21 Error Code Explained: Meaning, Causes & Fixes

Discover what Kohler Generator Code 21 means, its common causes, and how to fix it. Get quick troubleshooting tips to resolve this error and keep your generator running smoothly.

Kohler Generator Code 24 Error Code Explained: Meaning, Causes & Fixes

Discover what Kohler Generator Code 24 means, common causes behind this error, and step-by-step solutions to fix it. Quickly troubleshoot your generator with our expert guide.

Kohler Generator Accy PwrOver Warning Error Code Explained: Meaning, Causes & Fixes

Discover what the Kohler Generator "Accy PwrOver Warning" error code means, its common causes, and how to fix it. Get clear, step-by-step solutions to keep your generator running smoothly.

Cummins Generator SPN 175 FMI 3 Error Code Explained: Meaning, Causes & Fixes

Discover the meaning, common causes, and solutions for the Cummins Generator SPN 175 FMI 3 error code. Learn how to diagnose and fix this issue to keep your generator running smoothly.

Kohler Generator Code 23 Error Code Explained: Meaning, Causes & Fixes

Discover what Kohler Generator Code 23 means, common causes behind the error, and effective solutions to fix it. Get your generator running smoothly with these expert tips.

Cummins Generator SPN 284 FMI 4 Error Code Explained: Meaning, Causes & Fixes

Discover the meaning, common causes, and solutions for Cummins Generator SPN 284 FMI 4 error code. Quickly troubleshoot and resolve this generator issue with our expert guide.