What does the HE error code on Kohler a Generator mean?

 

What the HE Error Code Means on a Generator

 

When you see the “HE” error code on your generator, it almost always stands for “High Engine temperature.” This means the generator’s engine has gotten too hot while it’s running, and the machine is alerting you to prevent damage. Most modern residential and commercial generators are built with automatic shutdown features when they detect that the engine temperature goes above a safe level. This helps prevent serious and expensive engine damage. If you’re in the St Louis or Nashville areas and your generator shows this code, it’s a warning that needs quick attention.

 

Why a Generator Overheats

 

A generator’s engine can overheat for several reasons:

  • Low Coolant Level: Like a car engine, many generators use a coolant fluid that absorbs and carries away engine heat. If the coolant level is too low, heat can’t be removed fast enough and temperatures rise quickly.
  • Blocked or Dirty Radiator: The radiator takes that engine heat and releases it into the surrounding air. If it’s clogged with dirt, debris, or dust, airflow is blocked and the engine can’t cool itself properly.
  • Coolant Leak: Leaks in hoses, joints, or the radiator itself can mean there’s not enough coolant, directly leading to overheating.
  • Broken or Malfunctioning Fan: The fan pulls air through the radiator to help cooling. If the fan is broken, stuck, or its belt is damaged, cooling is reduced dramatically.
  • Overloading: Running the generator with more appliances or equipment than it’s designed for can make the engine work too hard and get hot.
  • Dirty Engine Oil: Old or dirty engine oil doesn’t lubricate or cool as well as clean oil. That means more friction and more heat.
  • Poor Ventilation: If the generator is in a small, closed space—especially in cities like St Louis or Nashville where some homes and businesses have limited outdoor space—hot air can’t escape. This traps heat and causes the generator to overheat.

 

What to Do Right Away if You See the HE Code

 

If your generator displays the HE error code, here are practical steps to follow:

  • Turn Off the Generator: Shut it down to allow the engine to cool off. Never try to troubleshoot a running or hot generator.
  • Inspect Coolant and Oil Levels: Once it’s cool, check for proper coolant and oil levels. If levels are low or you spot leaks, do not run the generator until this is fixed.
  • Clear Debris: Check and remove any leaves, dust, or dirt from the radiator and air intake grills.
  • Check Placement: Make sure nothing is blocking the vents or the area around the generator, especially in confined spaces common in many St Louis or Nashville properties.
  • Do Not Ignore the Code: Restarting the generator repeatedly without fixing the cause may result in lasting engine damage, requiring expensive repairs or replacing the whole unit.

 

How to Prevent the HE Error in the Future

 

Staying ahead of generator overheating will keep your system reliable, especially when you’re depending on power during storms or outages in areas like St Louis or Nashville.

  • Regular Maintenance: Change engine oil and coolant as directed by your generator’s manufacturer or as recommended by local service professionals. This is the single best way to prevent overheating.
  • Keep the Area Clean: Routinely remove leaves, grass, and debris around your generator, and make sure the vents are open and clear.
  • Test Under Normal Load: Make sure not to connect more devices than your generator’s rated capacity allows. Overusing it can cause overheating and reduce generator lifespan.
  • Have Annual Professional Inspections: An experienced technician can detect issues you might miss, like small leaks, worn fans or belts, or early signs of clogging in the radiator or exhaust.

 

When to Call a Specialist

 

If you notice your generator is often showing the HE error, if the coolant level keeps dropping, or if the generator seems unusually noisy or smelly, it’s time to contact a professional. Reliable, knowledgeable teams in St Louis and Nashville can quickly diagnose and repair generator issues, ensuring you’ll have backup power when you need it.

 

Expert Generator Solutions Await!

Generator issues in St. Louis or Nashville? Our experts provide quick repairs and maintenance to keep you cool. Contact us today!

Request a quote

How to fix the HE Error on a Kohler Generator?

 

How to Fix the HE Error on a Kohler Generator

 

When your Kohler generator shows an "HE" error code, it stands for "High Engine Temperature." This warning means the generator's engine is running hotter than it should, which can seriously damage the engine if ignored. The HE code will usually cause the generator to shut down as a safety measure. Here’s a step-by-step guide anyone in St Louis or Nashville can follow to troubleshoot and resolve the issue.

 

Understanding the Root Causes of the HE (High Engine Temperature) Error

 

Several things can cause high engine temperature:

  • Low coolant level – The coolant keeps the engine at the right temperature. If it’s low, the engine overheats.
  • Cooling system blockage – Leaves, dirt, or debris may block the air flow or coolant flow.
  • Faulty radiator cap – A radiator cap that isn’t sealing properly allows coolant to escape or boil over.
  • Malfunctioning thermostat – If the thermostat sticks closed, coolant can’t circulate.
  • Broken cooling fan – The fan is vital for moving air to keep the engine cool.
  • Coolant leak – If hoses or the radiator have holes, coolant leaks out, causing engine overheating.
  • Sensor or wire failure – A faulty temperature sensor or a disconnected/corroded wire could falsely trigger the HE error.

 

What to Do Immediately When the HE Code Appears

 

  • As soon as the generator displays the HE code, turn off the machine right away to prevent further damage.
  • Allow the generator to cool for at least 30–60 minutes before opening any panels or inspecting it. The engine, radiator, and coolant can be extremely hot and can cause burns.

 

Step-by-Step Troubleshooting and Fixing the HE Error

 

  • Check Coolant Level: Locate the generator’s coolant reservoir—this is usually a translucent tank near the radiator. Make sure the coolant level is between the "MIN" and "MAX" lines. If it’s low, add the recommended coolant type for your Kohler model, never plain water.
  • Inspect for Visible Leaks: Look under the generator and around all coolant hoses, the radiator, and the engine block for any signs of wetness or dried coolant residue (which often appears as a colored stain or crust). Leaks should be repaired by tightening hose clamps or replacing damaged hoses.
  • Clear Airflow Blockages: Remove any debris from the radiator, grille, or cooling fan. Make sure there’s nothing around the generator that blocks air from moving freely through the radiator, such as leaves or dust.
  • Examine the Radiator Cap: When the engine is completely cool, carefully remove the radiator cap and check that the rubber seal is in good condition. Replace the cap if it looks cracked, hard, or doesn’t fit securely.
  • Check the Cooling Fan: Turn the generator manually (or press the fan test button if equipped) and make sure the cooling fan spins freely without any obstruction or unusual noise. If the fan doesn’t spin, it may need to be repaired or replaced.
  • Inspect the Thermostat: If comfortable, you can open the thermostat housing (when the engine is cold) to check if the thermostat appears stuck closed. However, thermostat replacement is typically a job for professionals serving areas like St Louis and Nashville.
  • Check for Faulty Sensors or Wiring: Follow the wires from the temperature sensor to their connections. Look for frayed wires, loose plugs, or corrosion. A faulty sensor can trip the HE code even if temperatures are normal. If you suspect this, a full diagnosis from a technician may be needed.

 

If the Problem Persists

 

If after these steps your Kohler generator still shows the HE error or overheats, avoid further attempts to operate it. Continued overheating can cause serious internal engine damage. At this point:

  • Contact a qualified generator service technician with experience in St Louis or Nashville.
  • Provide them with your generator’s model and serial number, and explain the troubleshooting steps you have already tried.

A professional will inspect deeper causes such as water pump failure, radiator blockages inside the unit, internal engine issues, or advanced electrical faults.

 

Routine Maintenance to Prevent Future HE Errors

 

The best way to avoid the HE error is regular maintenance:

  • Check coolant levels monthly and top off as needed.
  • Have the coolant flushed and replaced based on your generator’s maintenance schedule (usually every 2–5 years).
  • Keep the area around your generator clear of leaves, dirt, and debris.
  • Schedule professional inspections annually, especially before storm or high-usage seasons.

If you’re in either St Louis or Nashville, local professionals can help with both emergency service and routine maintenance for residential and commercial Kohler generators.

 

Areas Of Expertise

We treat our people as our top priority so they'll treat you the same way. 100% Satisfaction, Every Time!

Air Conditioning

Providing air conditioning repairs, installation and maintenance for St Louis, MO and Nashville, TN. During the hot summers, call Hoffmann Brothers for all your AC repairs, replacement, and tuneup needs.

Electrical Repair

Hoffmann Brothers offers residential and commercial electrical services for St Louis homes and businesses. Lighting, outlets, panels, whole house fans, generators, and more. Call our licensed electricians today!

Heating Services

Need a furnace repair in St Louis or Nashville? Hoffmann Brothers can handle all your heating repairs, no matter the brand, including ductless mini-split systems. We also proudly offer heating system installations, and ongoing maintenance services.

Appliances

Hoffmann Brothers offers appliance repair services throughout St Louis, MO! Our experienced technicians are trained to work on all major brands of most home appliances including Dishwashers, Refrigerators & Freezers, Washing Machines & Dryers, and Ovens.

Plumbing Services

Hoffmann Brothers is your experienced Plumbing Company service both St Louis and Nashville. We offer plumbing repairs and installations, along with drain and sewer solutions.

Commercial Services

Do you need Mechanical or Commercial services for your St Louis or Nashville area business? We offer HVAC, Plumbing, Electrical (St Louis only), Indoor Air Quality, and more.

Water Heaters

Hoffmann Brothers is your professional water heater contractors for both Nashville, TN and St Louis, MO. We provide hot water heater installation, repair, and maintenance for both standard and tankless systems.

Drains & Sewers

Hoffmann Brothers is your Nashville and St Louis area drain Plumber. We provide drain cleaning and clearing and much more. Trust our drain experts to fix your clogged sink or toilet quickly and efficiently.

What could be causing the HE error code on a Kohler Generator?

 

Understanding the HE Error Code on a Kohler Generator

 

When you see the HE error code on your Kohler generator, it typically means "High Engine Temperature." In simple words, the generator's engine is running hotter than normal, which can eventually damage the engine if not addressed. This error code is designed to let the owner know that the generator needs a break or there may be a problem causing it to overheat.

 

What Happens in a Generator When the HE Code Appears?

 

The generator’s engine burns fuel to create electricity. Just like a car, this engine gets hot while it’s working. Every Kohler generator is designed with sensors that monitor the temperature of the engine. If these sensors detect that the engine is getting hotter than it should (more than its safe limit), the system will automatically show the HE error code and may even shut itself down to prevent major damage.

 

Possible Causes for the HE Error Code

 

There are a variety of reasons the HE error might be showing up:

  • Low Coolant Level: Generators have a cooling system, often similar to a car’s radiator, with coolant fluid. If this coolant is too low, it can't carry enough heat away from the engine, causing it to get hotter than normal.
  • Blocked or Dirty Radiator: The radiator and its fins help transfer heat out of the generator. Dust, dirt, or even leaves (especially in outdoor environments like those found in St Louis and Nashville) can block airflow, trapping heat inside.
  • Faulty Cooling Fan: The fan pulls air through the radiator. If the fan is broken, seized, or not spinning fast enough, there won’t be enough airflow to keep the engine cool.
  • Broken or Old Thermostat: A thermostat in the cooling system controls when coolant moves through the engine. If it's stuck closed, coolant can't circulate properly, and the engine overheats.
  • Coolant Pump Failure: The coolant pump moves coolant around the system. If this component fails, coolant sits still and cannot moderate the engine temperature. This is a common cause during regular generator use in places with variable weather, like St Louis or Nashville.
  • Heavy Load Demand: When the generator is asked to power too many appliances or systems at once, it has to work much harder. This can lead to overheating, especially if cooling systems are not in perfect condition.
  • Very Hot Outdoor Temperatures: If it’s extremely hot outside, the cooling system may struggle to keep the engine cool, especially in humid summers seen in St Louis or during peak heat in Nashville.
  • Low Engine Oil: Engine oil helps lubricate moving parts and also removes some heat. If oil is low or old, the engine can get hotter than normal.
  • Clogged or Dirty Air Filter: The air filter keeps dust and dirt out of the engine. If it’s clogged, the engine can’t get enough air, causing it to run hot.
  • Sensor or Wiring Issue: Sometimes, it’s not even the engine but a faulty temperature sensor, loose wire, or connector making the control system think the engine is overheating when it’s not.

 

Why It's Important to Address the HE Code Quickly

 

Ignoring the HE error code can lead to expensive repairs or even total engine failure. The error shows up to protect your investment—so whether your property is in St Louis or Nashville, understanding this warning lets you act quickly to minimize damage.

 

In Summary: What's Causing the HE Error on Your Kohler Generator?

 

The HE error code usually signals that your generator’s engine is running too hot. The most common causes are low coolant, a blocked or dirty radiator, fan or water pump failure, heavy use in hot climates, an overworked generator, or problems with sensors and wiring. In both St Louis and Nashville, seasonal changes and local conditions can play a role, but the underlying issues generally relate to the cooling and airflow systems. Always investigate this error code seriously to prevent further problems.

SERVING

St. Louis & Nashville Areas

Brentwood, MO
1025 Hanley Industrial
Brentwood, MO 63144

Nashville, TN
45 Willow St.
Nashville, TN 37210

Call Our St. Louis Office

Call Our Nashville Office

Nashville Location

(615) 515-3015

Read More

Kohler Generator Code 21 Error Code Explained: Meaning, Causes & Fixes

Discover what Kohler Generator Code 21 means, its common causes, and how to fix it. Get quick troubleshooting tips to resolve this error and keep your generator running smoothly.

Kohler Generator Code 24 Error Code Explained: Meaning, Causes & Fixes

Discover what Kohler Generator Code 24 means, common causes behind this error, and step-by-step solutions to fix it. Quickly troubleshoot your generator with our expert guide.

Kohler Generator Accy PwrOver Warning Error Code Explained: Meaning, Causes & Fixes

Discover what the Kohler Generator "Accy PwrOver Warning" error code means, its common causes, and how to fix it. Get clear, step-by-step solutions to keep your generator running smoothly.

Cummins Generator SPN 175 FMI 3 Error Code Explained: Meaning, Causes & Fixes

Discover the meaning, common causes, and solutions for the Cummins Generator SPN 175 FMI 3 error code. Learn how to diagnose and fix this issue to keep your generator running smoothly.

Kohler Generator Code 23 Error Code Explained: Meaning, Causes & Fixes

Discover what Kohler Generator Code 23 means, common causes behind the error, and effective solutions to fix it. Get your generator running smoothly with these expert tips.

Cummins Generator SPN 284 FMI 4 Error Code Explained: Meaning, Causes & Fixes

Discover the meaning, common causes, and solutions for Cummins Generator SPN 284 FMI 4 error code. Quickly troubleshoot and resolve this generator issue with our expert guide.