Kohler Generator Code 22 Error Code Explained: Meaning, Causes & Fixes

Discover what Kohler Generator Code 22 means, its common causes, and effective solutions. Quickly troubleshoot and resolve this error to keep your generator running smoothly.

Reviewed by Content Team

Head of Content, D. Gorenko

Updated June, 5

What does the Code 22 error code on Kohler a Generator mean?

 

What the Code 22 Error Means on a Generator

 

When you see a Code 22 error on your generator, it is telling you that the engine has been shut down due to "Low Oil Pressure." This is a safety feature built into almost all modern generators, including those installed in homes and businesses throughout St Louis and Nashville. The purpose of this code is to prevent engine damage, because running a generator without enough oil pressure can very quickly ruin the engine, leading to expensive repairs or even full replacement.

 

What Is Oil Pressure and Why Is It Important?

 

Oil pressure is the force that pushes oil through the engine. Inside a generator’s engine, oil is critical because it keeps all the metal moving parts lubricated. If there isn’t enough pressure, the oil can’t reach important areas, and friction between metal pieces can occur. Too much friction leads to overheating, wear, and engine failure.

The generator watches oil pressure levels with a sensor, and if the oil pressure drops below a safe level, it triggers the Code 22 error and automatically shuts down to protect itself.

 

What Causes the Code 22 Low Oil Pressure Error?

 

Many things can set off the Code 22 error. Some are simple fixes, while others need professional help from technicians familiar with systems in St Louis or Nashville.

  • Low Oil Level: The most common reason is simply that there isn’t enough oil in the engine. Check the oil level using the dipstick, just like you would in a car.
  • Dirty or Old Oil: If oil is thick, dirty, or old, it won’t flow well and can lower oil pressure. Regular oil changes keep the engine protected.
  • Oil Leaks: Sometimes, oil can leak out from gaskets, seals, or drain plugs. Even a small leak can lower the oil pressure.
  • Using the Wrong Oil: If the wrong type or weight of oil has been used, it might not provide enough pressure.
  • Faulty Oil Pressure Sensor: Sometimes the sensor gives a false reading, shutting down the generator even though pressure is fine. This is less common but can happen.
  • Engine Internal Problems: Worn out bearings or oil pump problems inside the engine can cause pressure to drop. These are rare, but serious.

 

What Should You Do if You See Code 22?

 

  • Check Oil Level: Make sure the generator is off and cooled down. Use the dipstick to check for the right oil level. Top up if it’s low, using the oil type recommended by the manufacturer or a trusted local service provider in St Louis or Nashville.
  • Inspect for Leaks: Look around the base of the generator for any oil spots or drips.
  • Look at the Oil: If the oil looks very dark, thick, or has particles in it, it’s time for a change.
  • Reset the Error: Once you’ve corrected the low oil condition, most generators allow you to clear the error code by pressing “Reset” or “Enter.”
  • Monitor Performance: If you refill with oil and the problem returns quickly, or you can’t find the reason for low pressure, stop running the generator and get professional help. Don’t keep resetting the code and forcing the engine to run—serious damage can happen.

 

How Professionals in St Louis and Nashville Help With Code 22

 

Certified technicians have the tools and expertise to inspect generators safely and efficiently. This includes checking the engine for leaks, measuring true oil pressure, and testing the sensor itself. Sometimes, sensors or wiring need to be replaced. More rarely, if there’s internal damage (like failed pumps or bearings), they can assess and fix those issues—in some cases saving the generator from total failure.

For both homeowners and business operators in St Louis and Nashville, keeping up with professional maintenance and oil changes helps prevent the Code 22 error from appearing in the first place.

 

How to Prevent Code 22 Errors

 

  • Check oil levels every month, especially during heavy use seasons.
  • Set up regular oil changes, just like you would with your car.
  • Watch for signs of leaks or engine stains around your generator.
  • Have a professional inspect the generator annually, especially before hurricane season or winter outages.

A Code 22 error on a generator is a clear warning that oil pressure is dangerously low, and it’s the machine’s way of protecting itself. Usually, it’s a simple fix—adding oil or changing it. But ignoring it or resetting the error without finding the cause can create very expensive problems. Understanding and responding the right way keeps your generator healthy, whether it’s powering homes or businesses here in St Louis or over in Nashville.

Expert Generator Solutions Await!

Generator issues in St. Louis or Nashville? Our experts provide quick repairs and maintenance to keep you cool. Contact us today!

Request a quote

How to fix the Code 22 Error on a Kohler Generator?

 

Understanding Kohler Generator Code 22 Error and Fixing It

 

If you see a Code 22 error on your Kohler generator, it means there’s a problem with the generator’s engine speed: either the engine is running too fast or too slow, and the generator system can’t operate safely. This error is usually called an “Over Speed Shutdown.” When Code 22 shows up, the generator will shut off to protect itself from potential engine damage. You’ll need to resolve this issue before you can reliably use your power backup again. Here’s exactly how to approach fixing Code 22, whether you’re in St Louis or Nashville, and how the experts at Hoffman Brothers typically tackle it for local customers.

 

What Causes Code 22 on a Kohler Generator?

 

  • Engine Speed Sensor Problems: The sensor might be faulty, dirty, or its wiring could have issues. This sensor lets the control board know how fast the engine is turning.
  • Fuel Supply Issues: If the engine isn’t getting the right amount of fuel (gas, propane, or diesel), it can cause over or under-speed — typically from clogged filters, low pressure, or air in fuel lines.
  • Governor Malfunction: The governor is a mechanical or electronic device that keeps engine speed steady. If it fails or is out of adjustment, speed problems and shutdowns will occur.
  • Control Board Faults: Sometimes the electronic control unit (the “brain” of the generator) misreads signals, which can throw Code 22 by mistake.

 

Step-by-Step Instructions to Fix Code 22 Error

 

  • Reset the Generator First
    Turn off the generator using the control panel and wait for a minute. Then turn it back on. Sometimes, Code 22 is a one-time hiccup. If the error clears, observe the next startup. If it comes back, continue troubleshooting.
  • Inspect Engine Speed Sensor and Wiring
    Locate the speed sensor — check your Kohler manual for the exact position (it’s usually found near the flywheel or crankshaft). Inspect the wiring for any loose plugs, damaged insulation, or corrosion. Unplug and clean the connectors with electrical contact cleaner if dirty. If there’s visible damage or the sensor looks cracked, it’ll need to be replaced. Hoffman Brothers teams in St Louis and Nashville carry standard parts and can replace this quickly if you’re unsure.
  • Check the Fuel System
    Ensure the main fuel shutoff valve is open fully. Look for kinks in fuel hoses, check for leaks, and make sure filters aren’t clogged (refer to your manual to locate and check the fuel filter). If you smell fuel or see leaks, don’t run the generator! For propane or natural gas units, check pressure and call your supplier if you suspect a problem with supply. Clean or replace filters if needed.
  • Examine and Adjust the Governor Linkage
    With the generator powered OFF, gently move the governor arm (a small rod or lever attached to the engine and throttle). It should move freely and return to its neutral position. If it’s stiff or binding, linkage parts may need lubrication or adjustment. Loose or broken governor springs are a common cause of speed fluctuations. You may refer to the service manual or call a qualified technician from Hoffman Brothers in St Louis or Nashville for correct adjustment.
  • Look for Control Board and Internal Faults
    If you’ve checked all above and the error persists, the generator’s control board may not be functioning correctly. Physical damage or moisture can short-circuit sensitive electronics. Inspect for visible damage and look for corrosion around terminals. Board-level repairs require experience — this is usually where most homeowners and building managers in St Louis and Nashville will call a licensed service provider like Hoffman Brothers for further diagnostics.

 

How to Prevent Code 22 on a Kohler Generator

 

  • Have your generator professionally serviced at least once a year. Annual inspections catch fuel, sensor, and governor issues early.
  • Start your generator monthly to make sure it runs smoothly, and listen for odd noises or sudden speed changes.
  • Keep surrounding areas clear so ventilation isn’t blocked, which can cause odd running problems.
  • Replace fuel and air filters as directed by your Kohler maintenance manual.
  • Watch for error codes and don’t ignore early warnings — many shutdowns start with minor faults.

 

When to Call In Professional Help

 

If you’ve tried these solutions and Code 22 keeps coming back, or if you’re unsure about any step, it’s time to call in a service technician. Hoffman Brothers has teams ready for both St Louis and Nashville, specializing in both residential and commercial generator repairs. Because engines and generator electronics deal with hazardous voltages and fuel, it’s always safest to consult a professional if you’re uncomfortable proceeding further.

With these steps, you should be able to confidently address a Code 22 error on your Kohler generator. If you’re in St Louis or Nashville and need assistance, help is nearby.

Areas Of Expertise

We treat our people as our top priority so they'll treat you the same way. 100% Satisfaction, Every Time!

Air Conditioning

Providing air conditioning repairs, installation and maintenance for St Louis, MO and Nashville, TN. During the hot summers, call Hoffmann Brothers for all your AC repairs, replacement, and tuneup needs.

Electrical Repair

Hoffmann Brothers offers residential and commercial electrical services for St Louis homes and businesses. Lighting, outlets, panels, whole house fans, generators, and more. Call our licensed electricians today!

Heating Services

Need a furnace repair in St Louis or Nashville? Hoffmann Brothers can handle all your heating repairs, no matter the brand, including ductless mini-split systems. We also proudly offer heating system installations, and ongoing maintenance services.

Appliances

Hoffmann Brothers offers appliance repair services throughout St Louis, MO! Our experienced technicians are trained to work on all major brands of most home appliances including Dishwashers, Refrigerators & Freezers, Washing Machines & Dryers, and Ovens.

Plumbing Services

Hoffmann Brothers is your experienced Plumbing Company service both St Louis and Nashville. We offer plumbing repairs and installations, along with drain and sewer solutions.

Commercial Services

Do you need Mechanical or Commercial services for your St Louis or Nashville area business? We offer HVAC, Plumbing, Electrical (St Louis only), Indoor Air Quality, and more.

Water Heaters

Hoffmann Brothers is your professional water heater contractors for both Nashville, TN and St Louis, MO. We provide hot water heater installation, repair, and maintenance for both standard and tankless systems.

Drains & Sewers

Hoffmann Brothers is your Nashville and St Louis area drain Plumber. We provide drain cleaning and clearing and much more. Trust our drain experts to fix your clogged sink or toilet quickly and efficiently.

What could be causing the Code 22 error code on a Kohler Generator?

 

What Causes Code 22 Error on a Kohler Generator?

 

When your Kohler generator shows a Code 22 error, it means that the unit has detected "Overcrank"—in other words, the engine tried and failed to start after several attempts. This is a built-in safety feature to protect the generator and avoid damaging the starter system. It automatically stops additional attempts to start until a human intervenes to resolve the cause of the issue.

 

What "Overcrank" Means in Simple Terms

 

Overcrank happens when the generator’s engine is cranked (spun by the starter motor) too many times in a row, but never actually starts running. The generator tries to start, but something stands in the way—like running out of gas, worn-out parts, or even the weather in St Louis or Nashville, where temperature swings can directly affect engine starting.

 

Main Reasons for Code 22 on Kohler Generators

 

  • Fuel Issues: If your generator is out of fuel, has contaminated gas, or isn’t getting fuel where it needs to go, the engine can’t start. In areas like St Louis and Nashville, gasoline can degrade over months, especially if the generator isn’t run often.
  • Empty or Closed Gas Lines: Sometimes, the fuel valve is turned off by accident, or the gas line may be blocked or leaking. This prevents fuel from reaching the engine.
  • Battery Problems: The generator uses its battery to power the starter motor. A weak or dead battery doesn’t spin the engine fast enough, which leads to overcrank. Extreme cold (like winter in St Louis) often drains batteries faster.
  • Faulty Spark Plug or Ignition System: If the spark plug is dirty, old, or broken, the fuel and air inside the cylinder can’t ignite properly. Sometimes, the ignition coil or control module (the electronic part that creates the spark) is at fault.
  • Poor Air Supply or Dirty Filters: The engine needs oxygen to start. If the air filter is clogged, or debris blocks air flow, the mixture of air and fuel will be off, causing failed starts.
  • Choke or Throttle Problems: These components control the amount of air/fuel going into the engine, especially during startup. If things get stuck open or closed, starting becomes difficult.
  • Engine Oil Levels and Pressure: Some Kohler generators have safety features that prevent startup if oil is low. Low oil keeps the engine safe from damage, but it also triggers failed start attempts leading to Code 22.
  • Faulty Starter Motor or Related Wiring: If wires are corroded or damaged, or the starter motor is worn, the engine may crank slowly or not at all.
  • Temperature Extremes: Very cold weather in places like St Louis or hot, humid conditions in Nashville make engines harder to start. Oils thicken or fuel may vaporize too quickly, both causing failed starts.
  • Problems With Generator Control Board: The control board is like the "brain" of your generator. Sometimes electronic glitches or sensor failures can confuse the starting logic, resulting in a Code 22.
  • Loose or Corroded Connections: Electrical connections, including those for the battery, starter, sensors, and control unit, can loosen or rust over time, making reliable engine starting difficult.

 

Why Code 22 Means Reliable Safety Protection

 

When a Kohler generator in St Louis or Nashville shows a Code 22 error, it’s actually preventing more serious mechanical damage. Multiple failed starts can lead to starter motor burnout, battery drain, or flooding the engine with fuel. By showing this error, the generator is alerting you that something needs attention before it can safely provide backup power again.

 

How Environment and Usage Patterns Affect Code 22

 

Where and how you use your Kohler generator influences the likelihood of seeing a Code 22. In St Louis, generators may sit unused for months, allowing fuel to go stale. In the heat and humidity of Nashville, evaporation and corrosion are more common. Light commercial use or constant residential standby will each put different stresses on the generator components, leading to specific vulnerability to Code 22 errors.

 

The Bottom Line

 

A Code 22 error on a Kohler generator means the engine tried and failed to start multiple times for any number of reasons—mainly fuel, battery, ignition, control, or environmental issues. Each of these possible causes is rooted in real-world scenarios, like harsh winters in St Louis, summers in Nashville, or simple lack of regular maintenance. The Code 22 is a warning that helps avoid further stress or damage to the generator’s essential parts. Understanding the root causes can help you communicate more clearly with professionals when seeking help for your generator.

SERVING

St. Louis & Nashville Areas

Brentwood, MO
1025 Hanley Industrial
Brentwood, MO 63144

Nashville, TN
45 Willow St.
Nashville, TN 37210

Call Our St. Louis Office

Call Our Nashville Office

Nashville Location

(615) 515-3015

Read More

Kohler Generator Code 21 Error Code Explained: Meaning, Causes & Fixes

Discover what Kohler Generator Code 21 means, its common causes, and how to fix it. Get quick troubleshooting tips to resolve this error and keep your generator running smoothly.

Kohler Generator Code 24 Error Code Explained: Meaning, Causes & Fixes

Discover what Kohler Generator Code 24 means, common causes behind this error, and step-by-step solutions to fix it. Quickly troubleshoot your generator with our expert guide.

Kohler Generator Accy PwrOver Warning Error Code Explained: Meaning, Causes & Fixes

Discover what the Kohler Generator "Accy PwrOver Warning" error code means, its common causes, and how to fix it. Get clear, step-by-step solutions to keep your generator running smoothly.

Cummins Generator SPN 175 FMI 3 Error Code Explained: Meaning, Causes & Fixes

Discover the meaning, common causes, and solutions for the Cummins Generator SPN 175 FMI 3 error code. Learn how to diagnose and fix this issue to keep your generator running smoothly.

Kohler Generator Code 23 Error Code Explained: Meaning, Causes & Fixes

Discover what Kohler Generator Code 23 means, common causes behind the error, and effective solutions to fix it. Get your generator running smoothly with these expert tips.

Cummins Generator SPN 284 FMI 4 Error Code Explained: Meaning, Causes & Fixes

Discover the meaning, common causes, and solutions for Cummins Generator SPN 284 FMI 4 error code. Quickly troubleshoot and resolve this generator issue with our expert guide.