Generac Generator 3717 Error Code Explained: Meaning, Causes & Fixes

Discover what the Generac Generator 3717 error code means, its common causes, and practical solutions. Quickly troubleshoot and restore your generator’s performance with our easy guide.

Reviewed by Content Team

Head of Content, D. Gorenko

Updated June, 5

What does the 3717 error code on Generac a Generator mean?

 

Understanding the Generac Generator 3717 Error Code

 

When you see the 3717 error code on your Generac generator, it specifically means “Service Mode – Exerciser Set For Off.” To put it simply, your automatic scheduled weekly exercise cycle (or “self-test”) for the generator has been manually turned OFF. This is not an equipment failure, a wiring error, or a mechanical problem, but a programming or setting issue related to how your generator is scheduled to automatically run itself and keep ready in case of an outage.

 

What Is the Exercise Cycle and Why Is It Important?

 

Generators, especially standby home models seen throughout locations like St. Louis and Nashville, are designed to turn on for a short period each week—all by themselves—to make sure the engine remains in good working condition. This routine is called the “exercise cycle” or “self-test.” It keeps critical parts lubricated, the battery charged, and helps detect any potential problems before the generator is truly needed during a power outage.

If the exerciser is set to “OFF,” your generator will not start its practice runs. As a result, you won’t know if your system is silently developing issues—like a weak battery or fouled spark plugs—until it’s too late and you truly need backup power.

 

Common Causes of the 3717 Code

 

The 3717 error will appear if:

  • The routine exercise cycle was intentionally turned off via the control panel/menu by a homeowner, technician, or through remote monitoring.
  • The generator was recently serviced or reset, and the default setting was changed without scheduling a new exercise time.
  • There was a malfunction or interruption in the generator’s programming due to a power surge, battery replacement, or control board reset.

In neighborhoods all over St. Louis and Nashville, people sometimes turn off the exerciser during long trips, home renovations, or extended generator repairs and forget to restore it.

 

How Do You Fix a 3717 Error Code?

 

This code generally does not reflect a dangerous issue but should be addressed to maintain system reliability. Follow these steps:

  • Locate the generator’s control panel. Make sure the system is in “OFF” or “Ready to Run” mode (not during actual operation).
  • Navigate to the “Edit” or “Set Exercise” menu. The procedure varies by model, but modern Generac displays will use up/down arrows or rotational dials with a menu button.
  • Select your preferred day and time of the week for the exerciser (for example, Tuesday at 10:00 a.m.). Confirm your selection and ensure the exerciser is switched to “ON.”
  • The control panel should display confirmation that the exercise cycle is active and will show the next scheduled run date and time.
  • Clear the error code by scrolling to the alerts or faults menu and acknowledging or resetting the code if necessary (some models clear this automatically after exercise is set).

If you’re unsure, your owners manual has step-by-step instructions for your specific model. Homeowners across St. Louis and Nashville often find online tutorial videos from Generac helpful as well.

 

When Should You Call for Professional Assistance?

 

If you attempt the steps above and the 3717 code persists, or if the control panel does not function properly, it is wise to contact a local generator expert. This could indicate an unrelated control board, wiring, or firmware problem that needs to be inspected by someone experienced in Generac systems.

Residents and business owners in St. Louis and Nashville rely on dependable generator operation, especially during severe weather months where automatic backup power is crucial for comfort and safety.

 

Key Takeaways About the 3717 Error Code

 

  • The 3717 code means the generator will not perform its automatic weekly exercise because it’s set to “OFF” in the settings.
  • This is not an emergency, but it compromises long-term reliability if not corrected.
  • You can follow the generator’s menu prompts to re-enable the exercise cycle and resolve the code.
  • If you need assurance that your generator will work when you need it, especially in areas like St. Louis and Nashville, always keep the automatic exerciser enabled and seek help from a trusted service provider if errors persist.

Expert Generator Solutions Await!

Generator issues in St. Louis or Nashville? Our experts provide quick repairs and maintenance to keep you cool. Contact us today!

Request a quote

How to fix the 3717 Error on a Generac Generator?

 

Understanding and Resolving the Generac Generator 3717 Error

 

The 3717 error on a Generac generator is a common alert that indicates the generator has registered a service issue, most often relating to the controller’s ability to communicate with the generator (called “Loss of Communication with Controller”). Essentially, it means that the digital control panel and the main generator electronics are not talking to each other as they should. When you see the 3717 code, your generator may not run or may not perform automatic functions properly until the issue is addressed.

 

Immediate Steps to Safely Address the Error

 

  • Safety First: Before working on the generator, make sure it is in ‘Off’ mode. Disconnect power to the unit by switching it off at the control panel and, if comfortable, switch off the main breaker for the unit as well. Avoid touching any wires or internal parts unless you are certain the power is disconnected.

 

Inspecting the Generator’s Connections

 

  • Check Visible Connections: Open the generator enclosure. Look specifically at all visible wire plugs and connectors around the control board and the transfer switch area.
  • Many times, the 3717 error is triggered by a loose, dirty, or corroded connector. Gently check that all communication cables and plugs (primarily the ones marked for the controller and generator communication) are firmly attached. Unplug these cables, inspect them for dirt, oxidation, moisture, or bent pins, then firmly reconnect.
  • If you spot corrosion, clean with an electrical-safe contact cleaner and a small brush. If any connectors are extremely dirty or damaged, they may need professional replacement (especially true in areas with high humidity like St. Louis or heavy pollen in Nashville).

 

Troubleshooting the Controller and Cables

 

  • Inspect Control Panel: Check the display panel for any signs of damage, water exposure, or error lights. If the control panel is unresponsive or the screen stays blank, the panel itself—or the relay board behind it—might be the source of the communication problem.
  • Cable Integrity: The communication cable (also called a data or harness cable) runs between the controller and the main motherboard. Trace its path as best as you can for any abrasions, rodent damage, or kinks that might cause a break in communication.
  • If you suspect cable damage but are unsure, you can gently wiggle the harness—a working connection shouldn’t cut out as you do this. If the screen flickers or the code resets, you likely have a faulty cable or connector.

 

Trying a Simple System Reset

 

  • If after checking connections you find nothing obvious, attempt a basic reset:
    • Turn the generator to ‘OFF’ using the control panel.
    • Wait about 5 minutes for any charge to dissipate, then turn the generator’s main breaker (if equipped) off and back on.
    • Switch the generator back to ‘AUTO’ or ‘ON’ mode.
    • Observe if the error code disappears and if normal functions resume.
  • If the code returns, the unit may require a deeper inspection.

 

When Professional Service is Needed

 

  • If you’ve checked all the above and the 3717 error persists, the issue could be with the internal controller board, broken solder joints, or a failed sensor—these problems require specialized equipment and expertise to repair safely.
  • For residents and businesses in St. Louis and Nashville, reaching out to a certified generator technician ensures compliance with safety standards and maintains your warranty.
  • Never attempt to open sealed electronic modules yourself as this can cause further damage or void warranties.
  • Explain to the technician the steps you took; this information helps speed up the diagnosis, especially for experienced service providers in St. Louis or Nashville.

 

Preventing Future 3717 Errors

 

  • Schedule routine generator maintenance at least annually—this includes checking all electrical connections and cleaning out any debris, moisture, or pests that can interfere with sensitive wires.
  • Ensure your generator housing is fully closed and weather-tight. St. Louis summers and Nashville storms can introduce humidity and debris that accelerate corrosion or short circuits.
  • Avoid running the generator with open panels or while installing yard equipment nearby, which can increase risk of connection issues.

 

You can resolve the Generac 3717 error by first safely shutting down the generator, checking and resecuring all communication cables and connectors, inspecting the control panel and wiring for any visible issues, and performing a simple system reset. If these steps don’t clear the error, it’s important to contact a professional generator technician, especially in weather-prone regions like St. Louis and Nashville. Prevent future errors through regular maintenance, moisture control, and timely repairs. This careful approach will ensure your Generac generator reliably powers your home or business when you need it most.

Areas Of Expertise

We treat our people as our top priority so they'll treat you the same way. 100% Satisfaction, Every Time!

Air Conditioning

Providing air conditioning repairs, installation and maintenance for St Louis, MO and Nashville, TN. During the hot summers, call Hoffmann Brothers for all your AC repairs, replacement, and tuneup needs.

Electrical Repair

Hoffmann Brothers offers residential and commercial electrical services for St Louis homes and businesses. Lighting, outlets, panels, whole house fans, generators, and more. Call our licensed electricians today!

Heating Services

Need a furnace repair in St Louis or Nashville? Hoffmann Brothers can handle all your heating repairs, no matter the brand, including ductless mini-split systems. We also proudly offer heating system installations, and ongoing maintenance services.

Appliances

Hoffmann Brothers offers appliance repair services throughout St Louis, MO! Our experienced technicians are trained to work on all major brands of most home appliances including Dishwashers, Refrigerators & Freezers, Washing Machines & Dryers, and Ovens.

Plumbing Services

Hoffmann Brothers is your experienced Plumbing Company service both St Louis and Nashville. We offer plumbing repairs and installations, along with drain and sewer solutions.

Commercial Services

Do you need Mechanical or Commercial services for your St Louis or Nashville area business? We offer HVAC, Plumbing, Electrical (St Louis only), Indoor Air Quality, and more.

Water Heaters

Hoffmann Brothers is your professional water heater contractors for both Nashville, TN and St Louis, MO. We provide hot water heater installation, repair, and maintenance for both standard and tankless systems.

Drains & Sewers

Hoffmann Brothers is your Nashville and St Louis area drain Plumber. We provide drain cleaning and clearing and much more. Trust our drain experts to fix your clogged sink or toilet quickly and efficiently.

What could be causing the 3717 error code on a Generac Generator?

 

Understanding the 3717 Error Code on a Generac Generator

 

When you see a 3717 error code on your Generac generator, it usually means there's a problem with the generator’s auxiliary shutdown switch circuit, which includes the Emergency Stop (E-Stop) switch or wiring attached to it. This code indicates that the generator believes the emergency stop circuit has been activated or there’s an issue in the wiring that creates the same effect, causing the unit to stop running as a safety precaution.

 

What is the Auxiliary Shutdown or Emergency Stop Circuit?

 

In simple terms, the auxiliary shutdown circuit is a safety feature found on most Generac generators, including those commonly installed in homes and businesses around St. Louis and Nashville. It involves switches (like an E-Stop button) or external wiring that, when triggered, immediately shuts off the generator to prevent damage, electrical hazards, or potential injury.

 

Possible Causes for the 3717 Error Code

 

Many things can trigger the 3717 fault code, and understanding each cause helps you see why the generator entered a safety shutdown.

  • Emergency Stop Switch Activation: If the red Emergency Stop button on or near your generator has been pressed by accident or deliberately, it will create a break in the circuit the generator constantly checks. As a result, the unit shuts down and records a 3717 code.
  • Loose or Disconnected Wires: The wiring that runs from the E-Stop switch or any other auxiliary shutdown switch back to the generator’s controller may become loose, unplugged, or disconnected due to vibration or accidental contact. Even a slight disconnect can mimic the effect of pressing the stop switch.
  • Corrosion or Dirt on Connections: In regions like St. Louis, which can experience humidity and temperature swings, or in Nashville where similar weather can occur, the exposed electrical contacts can corrode or gather dirt. This resistance can break the circuit, causing the generator to think the switch was pressed.
  • Broken or Damaged Wiring: Over time, rodents, weather, or mechanical damage can break or fray wires running to the E-Stop or auxiliary shutdown. Such damage can cause an open circuit, resulting in a 3717 fault.
  • Faulty Switch or Controller Board: Although less common, the E-Stop switch itself may fail or the generator's controller board may detect a problem incorrectly due to internal faults or circuit board defects.
  • Incorrect Installation or Service Issues: If the generator or its safety circuits have recently been installed, modified, or serviced (for example, after moving or remodeling your St. Louis home or upgrading a business in Nashville), improperly reconnected wiring or skipped steps can leave the circuit open, leading to an error.

 

Why the Generator Uses This Safety Feature

 

Generators have built-in safety features to protect people and equipment. The auxiliary shutdown circuit avoids dangerous scenarios by allowing immediate stopping in case of emergencies—like electrical faults or maintenance needs. The 3717 error is the machine’s way of telling you that it believes this protection must activate, usually for one of the reasons listed above.

 

Weather and Environmental Impact in St. Louis and Nashville

 

In areas like St. Louis and Nashville, seasonal weather—heat, cold, humidity, or storms—can gradually affect the generator’s wiring or components, especially if it’s installed outdoors or in unconditioned spaces. Over time, this can contribute to issues that lead to the 3717 code.

 

Summing It Up

 

A 3717 error code on a Generac generator means the emergency shutdown circuit is triggered—either by someone pressing a switch, wiring problems, corrosion, a bad switch, or control board issues. The safety shutdown protects your generator and property in both St. Louis and Nashville. Understanding these causes can help you see why the unit isn’t running and what might be happening with its safety system.

SERVING

St. Louis & Nashville Areas

Brentwood, MO
1025 Hanley Industrial
Brentwood, MO 63144

Nashville, TN
45 Willow St.
Nashville, TN 37210

Call Our St. Louis Office

Call Our Nashville Office

Nashville Location

(615) 515-3015

Read More

Kohler Generator Code 21 Error Code Explained: Meaning, Causes & Fixes

Discover what Kohler Generator Code 21 means, its common causes, and how to fix it. Get quick troubleshooting tips to resolve this error and keep your generator running smoothly.

Kohler Generator Code 24 Error Code Explained: Meaning, Causes & Fixes

Discover what Kohler Generator Code 24 means, common causes behind this error, and step-by-step solutions to fix it. Quickly troubleshoot your generator with our expert guide.

Kohler Generator Accy PwrOver Warning Error Code Explained: Meaning, Causes & Fixes

Discover what the Kohler Generator "Accy PwrOver Warning" error code means, its common causes, and how to fix it. Get clear, step-by-step solutions to keep your generator running smoothly.

Cummins Generator SPN 175 FMI 3 Error Code Explained: Meaning, Causes & Fixes

Discover the meaning, common causes, and solutions for the Cummins Generator SPN 175 FMI 3 error code. Learn how to diagnose and fix this issue to keep your generator running smoothly.

Kohler Generator Code 23 Error Code Explained: Meaning, Causes & Fixes

Discover what Kohler Generator Code 23 means, common causes behind the error, and effective solutions to fix it. Get your generator running smoothly with these expert tips.

Cummins Generator SPN 284 FMI 4 Error Code Explained: Meaning, Causes & Fixes

Discover the meaning, common causes, and solutions for Cummins Generator SPN 284 FMI 4 error code. Quickly troubleshoot and resolve this generator issue with our expert guide.