Learn what Generac Generator error code 3701 means, common causes behind it, and step-by-step fixes. Get your generator running smoothly again with this quick guide.

Head of Content, D. Gorenko
Updated June, 5
When your Generac generator displays the 3701 error code, it is telling you that the generator’s controller cannot detect the correct speed or frequency at startup. In simpler terms, the generator is having trouble reaching the proper running speed it needs to make electricity for your home or business in either St Louis or Nashville. This warning is often called an “Underspeed” or “RPM Sense Loss” fault. The generator wants to run at a steady pace so the electricity it creates is reliable, and this alert means something is stopping it from doing so.
Generators work best when their engine speed (which is measured in RPM, or “revolutions per minute”) is steady. Most residential Generac generators, like the ones seen across St Louis and Nashville, are designed to run at 3,600 RPM. This exact speed ensures the generator makes electricity at the right frequency (60 Hz), so your appliances run safely. When the engine starts running too slowly or can't keep up, the onboard controller senses a problem and triggers error code 3701 to protect both your home and the generator.
The 3701 code can happen for several reasons. These reasons can vary slightly based on your specific model or whether your generator is in St Louis or Nashville, but generally include:
If you see error code 3701, don’t panic, but do take action to avoid losing backup power when it’s needed most:
If basic steps don't clear the 3701 code, a professional technician with experience in generators should inspect your equipment—especially if you live in areas like St Louis or Nashville, where reliable backup power is vital during storms or utility outages. A technician will diagnose deeper issues using special tools to check sensors, control boards, and mechanical parts. They’ll also make sure your generator is safe for use and ready for the next power outage.
Regular service can prevent problems like the 3701 error code. Simple things like replacing air filters and spark plugs, testing the battery, and checking for loose wires catch most issues early. In cities like St Louis and Nashville, where climate can change quickly, annual checks are especially important to keep your generator running smoothly.

Generator issues in St. Louis or Nashville? Our experts provide quick repairs and maintenance to keep you cool. Contact us today!
Request a quote
The 3701 error on a Generac generator indicates that the generator has entered "Not In Auto" mode. This happens when the generator is not set to turn on automatically during a power outage. When you see this code on your generator control panel, it means the system needs to be reset to "Auto" mode so it’s ready to supply power if utility service is lost.
If you live in St Louis or Nashville, and you’re experiencing this issue, these steps will guide you through the process to resolve the 3701 error and get your generator back in proper working order.
When your Generac generator displays the 3701 error, it means your generator will not start automatically when your home loses power. This setting is important because it’s what allows the generator to kick in by itself—without you needing to do anything. If the system is in any mode besides "Auto," it will not respond to a power outage, making your backup power unavailable.
There are a few reasons why your generator might leave “Auto” mode:
If these steps do not resolve the problem, there may be another underlying issue with your generator. Possible causes could include:
In this situation, it is safest to contact a licensed generator repair specialist. If you are in St Louis or Nashville, local technicians familiar with Generac systems should be able to inspect, diagnose, and repair more complex issues.
After you have cleared the 3701 code and returned the generator to “Auto” mode, test the system to make sure it’s ready for the next outage:
Most often, the 3701 error occurs by mistake—such as after a test run or maintenance. After any service or troubleshooting task, always make sure the generator is set back to “Auto” mode. A quick check of the control panel can prevent future disruptions for homes or businesses around St Louis and Nashville.
It’s also a good idea to keep your generator professionally serviced at recommended intervals. Regular maintenance can catch minor issues before they lead to larger faults.
If resetting to “Auto” and clearing the 3701 error doesn’t work, or if you see other fault codes, do not attempt complex repairs yourself. Call a trained professional who services Generac generators in your area. Whether you are in St Louis or Nashville, a local expert can safely diagnose and fix the problem—ensuring your generator works reliably for years to come.
We treat our people as our top priority so they'll treat you the same way. 100% Satisfaction, Every Time!
Providing air conditioning repairs, installation and maintenance for St Louis, MO and Nashville, TN. During the hot summers, call Hoffmann Brothers for all your AC repairs, replacement, and tuneup needs.
Hoffmann Brothers offers residential and commercial electrical services for St Louis homes and businesses. Lighting, outlets, panels, whole house fans, generators, and more. Call our licensed electricians today!
Need a furnace repair in St Louis or Nashville? Hoffmann Brothers can handle all your heating repairs, no matter the brand, including ductless mini-split systems. We also proudly offer heating system installations, and ongoing maintenance services.
Hoffmann Brothers offers appliance repair services throughout St Louis, MO! Our experienced technicians are trained to work on all major brands of most home appliances including Dishwashers, Refrigerators & Freezers, Washing Machines & Dryers, and Ovens.
Hoffmann Brothers is your experienced Plumbing Company service both St Louis and Nashville. We offer plumbing repairs and installations, along with drain and sewer solutions.
Do you need Mechanical or Commercial services for your St Louis or Nashville area business? We offer HVAC, Plumbing, Electrical (St Louis only), Indoor Air Quality, and more.
Hoffmann Brothers is your professional water heater contractors for both Nashville, TN and St Louis, MO. We provide hot water heater installation, repair, and maintenance for both standard and tankless systems.
Hoffmann Brothers is your Nashville and St Louis area drain Plumber. We provide drain cleaning and clearing and much more. Trust our drain experts to fix your clogged sink or toilet quickly and efficiently.
When a Generac generator displays the 3701 error code, it means the unit did not start as expected during a scheduled exercise or automatic start attempt. In everyday terms, this error is usually called “Generator did not start” or “Exercise Cycle Did Not Start.” It can happen with both home and business generators, whether you’re in St Louis or Nashville. The cause can range from simple maintenance issues to more complex electrical or fuel-related problems.
The 3701 error code is triggered when the generator’s internal computer (the control board) tries to start the engine, but nothing happens. This is often picked up by a missed “exercise cycle”—the generator’s weekly or bi-weekly self-check where it turns on by itself to make sure it’s ready for emergencies. There are several key reasons why this could happen:
It’s not always the usual suspects. Less common but possible reasons—especially important in climates like those in St Louis and Nashville—can include:
Whether you’re running a standby generator at home in St Louis or managing critical power for a business in Nashville, the 3701 error can happen to anyone, especially if periodic maintenance hasn’t been done recently. Batteries wear out. Fuel supplies can be interrupted by utility service or empty tanks. Oil or filter changes get missed from busy schedules. Weather changes—like ice storms or heat waves—also stress generator systems more, exposing weak points.
In simple terms, the 3701 error on a Generac generator means the automatic system tried to start your generator for a routine self-check or automatic run—but the engine didn’t start up. The underlying reasons nearly always relate to a dead battery, fuel issues, wiring connections, oil level, controller settings, or less often, hardware malfunctions or environmental factors common to areas like St Louis and Nashville. Recognizing these causes is the first step to getting your generator ready for the next outage or emergency.
SERVING
Brentwood, MO
1025 Hanley Industrial
Brentwood, MO 63144
Nashville, TN
45 Willow St.
Nashville, TN 37210

St Louis Location
(314) 664-3011
St Louis Location
1025 Hanley Industrial Brentwood, MO 63144
Nashville Location
(615) 515-3015
Nashville Location
45 Willow St Nashville, TN 37210
Discover what Kohler Generator Code 21 means, its common causes, and how to fix it. Get quick troubleshooting tips to resolve this error and keep your generator running smoothly.
Discover what Kohler Generator Code 24 means, common causes behind this error, and step-by-step solutions to fix it. Quickly troubleshoot your generator with our expert guide.
Discover what the Kohler Generator "Accy PwrOver Warning" error code means, its common causes, and how to fix it. Get clear, step-by-step solutions to keep your generator running smoothly.
Discover the meaning, common causes, and solutions for the Cummins Generator SPN 175 FMI 3 error code. Learn how to diagnose and fix this issue to keep your generator running smoothly.
Discover what Kohler Generator Code 23 means, common causes behind the error, and effective solutions to fix it. Get your generator running smoothly with these expert tips.
Discover the meaning, common causes, and solutions for Cummins Generator SPN 284 FMI 4 error code. Quickly troubleshoot and resolve this generator issue with our expert guide.