Discover what Generac Generator 3700 Error Code means, common causes, and step-by-step fixes. Get your generator running smoothly with our quick troubleshooting guide.

Head of Content, D. Gorenko
Updated June, 5
When your Generac generator displays the 3700 error code, it’s alerting you to an "Under Voltage" condition. In plain terms, this means that your generator is running, but it’s producing less electricity, or voltage, than it should be. Generac generators are designed to produce a specific range of voltage so your appliances and systems get the right amount of power. If it goes under the set level (typically below 180 volts on a 240-volt system, but this can vary), the generator’s control board triggers the 3700 code to protect both the generator and your electrical equipment.
Voltage is the "pressure" that pushes electrical current through wires to your appliances and devices. When the voltage is too low (under voltage), sensitive electronics and motors may not work properly. They can run inefficiently, overheat, or even get damaged over time. That’s why Generac generators, found in homes and businesses throughout St Louis and Nashville, are equipped with error code systems to prevent these problems.
There are several possible reasons your Generac generator in St Louis or Nashville might show this under voltage code:
If you notice a 3700 under voltage error on your Generac generator, here’s what you should do:
If these basic steps don’t solve the issue, the problem could be internal and require a trained technician.
When experienced experts inspect a generator with a 3700 code, like those from Hoffman Brothers serving St Louis and Nashville communities, they take a systematic approach:
Professionals also make sure the generator’s software is up to date and that installation meets all local safety codes for the St Louis or Nashville area.
Generators work best when they’re properly maintained. Here’s how homeowners and businesses can prevent these voltage issues:
If you’re in St Louis or Nashville, weather can play a role in wear and tear, so stay proactive with regular checkups.
The 3700 error code on a Generac generator is a serious "under voltage" warning. It’s your generator’s way of protecting itself—and your valuable electronics—from harm. While you can check for simple fixes like removing overloads or replacing filters, more involved repairs almost always require a professional’s help. Regular maintenance and early action are your best ways to protect both your generator and everything it powers throughout St Louis and Nashville.

Generator issues in St. Louis or Nashville? Our experts provide quick repairs and maintenance to keep you cool. Contact us today!
Request a quote
The 3700 error on a Generac generator is a code that means the system is not seeing information from the main controller — in most cases, this signals a “Loss of Network Communication.” The generator’s ‘controller’ is kind of like its brain: it oversees all functions, including turning the generator on or off, and monitoring safety conditions. Losing communication with this part means the generator might not run or respond as normal, and the error needs to be fixed for safe and reliable operation. Whether your property is in St Louis or Nashville, these steps will help you to safely troubleshoot and address the issue.
Often, communication errors can be triggered by power interruptions, brief surges, or external electronic disturbances. Start by turning off the generator, waiting for about five minutes, and powering it on again. This simple reset can sometimes clear temporary glitches, especially after a storm or if utility power was recently restored at your St Louis or Nashville home or business.
If the error code appears immediately again or doesn’t clear, carefully open your generator’s access panel. You’ll need a flashlight and, for safety, ensure the generator is in “OFF” mode and cannot start unexpectedly. Look at the main controller display for any additional error messages or lights. Next, gently check that all visible wires, especially the communication cables (often a flat gray, red, or blue wire), are securely plugged into the control board and not damaged, loose, or corroded. Rodents or weather in St Louis or Nashville can cause loose or chewed wires.
Insufficient or interrupted power to the controller may also cause error 3700. Inspect the battery terminals for corrosion, looseness, or frayed connections. Gently clean and tighten as needed, but avoid overtightening, which could snap a terminal.
The communication wire is a special cable connecting the generator’s main controller to the Automatic Transfer Switch (where the system senses if there is a power outage and decides to run your generator). Look for any broken, pinched, or disconnected cable. If you’re not sure which one is which, it’s best to refer to the generator’s manual or contact a professional with specific experience in your area—like those familiar with local climates in St Louis and Nashville.
Ask yourself if there have been any recent electrical updates, landscaping projects, or storms around your home or business. Sometimes, underground wiring or external transfer switch wiring might have been disturbed or hit. In cities like St Louis and Nashville, power surges from summer storms or winter ice can impact sensitive electronic boards inside your generator.
If your generator is newer, its display screen might prompt you to check for “Controller Firmware Errors” or unsuccessful updates. If you see these, do not attempt to update firmware yourself. It is possible for a failed update or programmed setting to disrupt communication, which shows up as error 3700.
If the 3700 error does not clear after the steps above, or if you see frayed or damaged wiring, leave your generator off and reach out to an experienced technician. Modern generators involve both high-voltage wiring and delicate electronics, and improper DIY repairs can create safety risks or void a warranty. In both the St Louis and Nashville regions, experienced professionals understand local weather patterns and common causes for wiring and communication faults, ensuring safe, warranty-approved repairs.
Once the error is professionally cleared and the generator is running normally, schedule an annual maintenance check. Especially in climates like St Louis and Nashville, regular checks will help prevent future issues by keeping connections clean and protected, batteries healthy, and settings up-to-date.
We treat our people as our top priority so they'll treat you the same way. 100% Satisfaction, Every Time!
Providing air conditioning repairs, installation and maintenance for St Louis, MO and Nashville, TN. During the hot summers, call Hoffmann Brothers for all your AC repairs, replacement, and tuneup needs.
Hoffmann Brothers offers residential and commercial electrical services for St Louis homes and businesses. Lighting, outlets, panels, whole house fans, generators, and more. Call our licensed electricians today!
Need a furnace repair in St Louis or Nashville? Hoffmann Brothers can handle all your heating repairs, no matter the brand, including ductless mini-split systems. We also proudly offer heating system installations, and ongoing maintenance services.
Hoffmann Brothers offers appliance repair services throughout St Louis, MO! Our experienced technicians are trained to work on all major brands of most home appliances including Dishwashers, Refrigerators & Freezers, Washing Machines & Dryers, and Ovens.
Hoffmann Brothers is your experienced Plumbing Company service both St Louis and Nashville. We offer plumbing repairs and installations, along with drain and sewer solutions.
Do you need Mechanical or Commercial services for your St Louis or Nashville area business? We offer HVAC, Plumbing, Electrical (St Louis only), Indoor Air Quality, and more.
Hoffmann Brothers is your professional water heater contractors for both Nashville, TN and St Louis, MO. We provide hot water heater installation, repair, and maintenance for both standard and tankless systems.
Hoffmann Brothers is your Nashville and St Louis area drain Plumber. We provide drain cleaning and clearing and much more. Trust our drain experts to fix your clogged sink or toilet quickly and efficiently.
When a Generac generator shows the 3700 error code, it is indicating a "Low Oil Pressure Shutdown." This means the generator’s engine has experienced oil pressure below the safe level required for operation, so the system automatically stopped (shut down) to protect the engine from damage.
Oil is crucial for the generator’s engine, much like blood in the human body. It lubricates moving engine parts, reduces friction, and helps cool the engine. If the oil pressure gets too low, the moving parts inside the engine can rub against each other, overheat, and potentially cause severe, even permanent, damage. That’s why Generac generators—including those installed in homes and businesses in St Louis and Nashville—are programmed to stop working if they sense this issue.
Several things can trigger low oil pressure in a Generac generator. Each possibility comes from extensive experience maintaining both residential and commercial generator systems, especially in areas with climate extremes like St Louis and Nashville:
Auto-shutdown protects the generator from expensive engine repairs, fire hazards, or even total engine replacement. With a 3700 code, the generator is prioritizing safety, ensuring that home and business owners in St Louis and Nashville don’t face even larger outages or dangerous situations caused by continued engine operation without proper lubrication.
Ignoring the 3700 code isn’t recommended. It signals a real or potential threat to your generator’s engine. If you live in St Louis or Nashville, this code can mean you might face power interruptions during storms, extreme heat, ice, or other emergencies. Preventive maintenance—including checking oil levels, quality, and filters—can stop most of these issues before they start.
SERVING
Brentwood, MO
1025 Hanley Industrial
Brentwood, MO 63144
Nashville, TN
45 Willow St.
Nashville, TN 37210

St Louis Location
(314) 664-3011
St Louis Location
1025 Hanley Industrial Brentwood, MO 63144
Nashville Location
(615) 515-3015
Nashville Location
45 Willow St Nashville, TN 37210
Discover what Kohler Generator Code 21 means, its common causes, and how to fix it. Get quick troubleshooting tips to resolve this error and keep your generator running smoothly.
Discover what Kohler Generator Code 24 means, common causes behind this error, and step-by-step solutions to fix it. Quickly troubleshoot your generator with our expert guide.
Discover what the Kohler Generator "Accy PwrOver Warning" error code means, its common causes, and how to fix it. Get clear, step-by-step solutions to keep your generator running smoothly.
Discover the meaning, common causes, and solutions for the Cummins Generator SPN 175 FMI 3 error code. Learn how to diagnose and fix this issue to keep your generator running smoothly.
Discover what Kohler Generator Code 23 means, common causes behind the error, and effective solutions to fix it. Get your generator running smoothly with these expert tips.
Discover the meaning, common causes, and solutions for Cummins Generator SPN 284 FMI 4 error code. Quickly troubleshoot and resolve this generator issue with our expert guide.