Discover what the Generac Generator 1916 error code means, its common causes, and effective solutions. Learn how to troubleshoot and resolve this generator issue quickly.

Head of Content, D. Gorenko
Updated June, 5
The 1916 error code on a Generac generator indicates a specific communication problem within the generator system. To put it simply, your generator is telling you that it cannot properly talk to a part called the "Controller Canbus." This communication system is what allows different parts of the generator to send signals back and forth so everything works smoothly. The 1916 code therefore means that the generator's brain (the controller) is not able to get information from or send instructions to other essential components as it should.
If you see this code on your residential or commercial generator in St Louis or Nashville, it's important not to ignore it, as it may prevent your generator from operating correctly when you need backup power, whether at your home or business.
The Canbus is a type of internal wiring and communication line inside your generator. Think of it like a telephone system that allows the generator's main computer (controller) to stay in constant contact with other electronic modules (like engine controls, sensors, or display panels).
When this telephone line fails, and the controller can't reach these devices, your generator won’t know if things are working as they should. The 1916 error tells you this “conversation” has been interrupted. This is often described as a "Canbus Loss of Communication" fault.
Several issues can cause the 1916 code to appear on your Generac generator in St Louis and Nashville:
If you’re in St Louis or Nashville and come across this error code, here’s what you should consider doing:
A generator is just like any other piece of complex machinery—it works best with regular professional maintenance. For residents and business owners in St Louis and Nashville, the best way to keep your generator running reliably is to have it inspected and serviced at least once a year, even if you haven’t seen any errors. This helps catch loose wires, corrosion, and signs of component wear before they trigger the 1916 code or prevent the generator from providing backup power in an emergency.
By understanding what the 1916 error code means and knowing proper steps to take, you’ll be well-prepared to keep your generator ready for the next power outage—no matter if you’re running a business in St Louis or looking after your home in Nashville.

Generator issues in St. Louis or Nashville? Our experts provide quick repairs and maintenance to keep you cool. Contact us today!
Request a quote
The 1916 error code on a Generac Generator means there has been a “Low Voltage Error” detected in the generator’s system. This means your generator’s output voltage, or the power it’s generating, has dropped below what’s considered safe or normal for the generator to provide to your house or business in St Louis or Nashville. The generator senses this drop and automatically issues the 1916 error code to protect itself and appliances by turning itself off. This helps to stop any electrical damage from happening.
Sometimes, the 1916 error can be simple to fix, while in other situations you may need help from a professional service like those available in St Louis and Nashville. Here’s a detailed, step-by-step guide for how to fix this error:
If you’ve completed all the above steps and the generator is still showing the 1916 code, there is likely a more serious internal or electronic issue. This could be a failed voltage regulator, control board problem, or wiring fault inside the generator. Generators are complicated machines with high-voltage parts. At this stage, contact a trained, certified technician familiar with Generac generators who serves St Louis and Nashville areas. They have the special tools and knowledge to safely diagnose the problem and replace any broken parts without voiding your warranty or risking personal injury.
To help avoid this error in the future, keep up regular generator maintenance. This includes:
By following these steps, most common causes of the 1916 error on Generac generators can be solved or prevented. Always put safety first, and when in doubt, reach out to professionals for reliable and safe service.
We treat our people as our top priority so they'll treat you the same way. 100% Satisfaction, Every Time!
Providing air conditioning repairs, installation and maintenance for St Louis, MO and Nashville, TN. During the hot summers, call Hoffmann Brothers for all your AC repairs, replacement, and tuneup needs.
Hoffmann Brothers offers residential and commercial electrical services for St Louis homes and businesses. Lighting, outlets, panels, whole house fans, generators, and more. Call our licensed electricians today!
Need a furnace repair in St Louis or Nashville? Hoffmann Brothers can handle all your heating repairs, no matter the brand, including ductless mini-split systems. We also proudly offer heating system installations, and ongoing maintenance services.
Hoffmann Brothers offers appliance repair services throughout St Louis, MO! Our experienced technicians are trained to work on all major brands of most home appliances including Dishwashers, Refrigerators & Freezers, Washing Machines & Dryers, and Ovens.
Hoffmann Brothers is your experienced Plumbing Company service both St Louis and Nashville. We offer plumbing repairs and installations, along with drain and sewer solutions.
Do you need Mechanical or Commercial services for your St Louis or Nashville area business? We offer HVAC, Plumbing, Electrical (St Louis only), Indoor Air Quality, and more.
Hoffmann Brothers is your professional water heater contractors for both Nashville, TN and St Louis, MO. We provide hot water heater installation, repair, and maintenance for both standard and tankless systems.
Hoffmann Brothers is your Nashville and St Louis area drain Plumber. We provide drain cleaning and clearing and much more. Trust our drain experts to fix your clogged sink or toilet quickly and efficiently.
The 1916 error code on a Generac Generator specifically means there is a low voltage warning on the battery charger that keeps your generator’s battery charged. In simple terms, your generator is telling you there’s a problem with the system that makes sure its internal battery stays ready to start the generator when needed. The generator relies on this battery charger so that when the power goes out in places like St Louis or Nashville, your generator will turn on automatically.
This battery charger is a small device inside the generator. Its job is to take a little bit of electricity from your house and use it to keep the generator’s battery charged. If the battery is weak or dead, the generator may not start at all. The 1916 code tells you the charger isn’t providing enough voltage (electricity) to keep that battery healthy.
In residential neighborhoods or in businesses around St Louis and Nashville, the most typical root causes of a 1916 code include:
If your Generac generator is showing a 1916 error, it means the battery is not charging as it’s supposed to. If the problem continues, your battery could eventually drain completely. This will lead to one of two outcomes: your generator may not start up at all during an outage, or it may display additional error codes related to battery failure.
To sum up, the 1916 code is a warning that your generator’s automatic battery charging system isn’t getting enough electricity or isn’t working right. In St Louis and Nashville, this is often related to issues with house power supply, damaged charger, old battery, or wiring problems due to weather and age. This error is about the electrical health of the backup system your home or business relies on when the power goes out.
SERVING
Brentwood, MO
1025 Hanley Industrial
Brentwood, MO 63144
Nashville, TN
45 Willow St.
Nashville, TN 37210

St Louis Location
(314) 664-3011
St Louis Location
1025 Hanley Industrial Brentwood, MO 63144
Nashville Location
(615) 515-3015
Nashville Location
45 Willow St Nashville, TN 37210
Discover what Kohler Generator Code 21 means, its common causes, and how to fix it. Get quick troubleshooting tips to resolve this error and keep your generator running smoothly.
Discover what Kohler Generator Code 24 means, common causes behind this error, and step-by-step solutions to fix it. Quickly troubleshoot your generator with our expert guide.
Discover what the Kohler Generator "Accy PwrOver Warning" error code means, its common causes, and how to fix it. Get clear, step-by-step solutions to keep your generator running smoothly.
Discover the meaning, common causes, and solutions for the Cummins Generator SPN 175 FMI 3 error code. Learn how to diagnose and fix this issue to keep your generator running smoothly.
Discover what Kohler Generator Code 23 means, common causes behind the error, and effective solutions to fix it. Get your generator running smoothly with these expert tips.
Discover the meaning, common causes, and solutions for Cummins Generator SPN 284 FMI 4 error code. Quickly troubleshoot and resolve this generator issue with our expert guide.