Generac Generator 1911 Error Code Explained: Meaning, Causes & Fixes

Discover what the Generac Generator 1911 error code means, its common causes, and how to fix it quickly. Get troubleshooting tips to restore your generator’s performance.

Reviewed by Content Team

Head of Content, D. Gorenko

Updated June, 5

What does the 1911 error code on Generac a Generator mean?

 

Understanding the 1911 Error Code on Generac Generators

 

When your Generac generator shows the 1911 error code, it means the generator’s system has detected a problem specifically with its battery charger. Put simply, the generator is telling you that while it’s not actively running, it noticed the device responsible for keeping the battery charged isn’t working as expected. This is called a "Charger Missing AC" alarm.

 

What Does "Charger Missing AC" Mean?

 

All standby generators, including those commonly installed by Hoffman Brothers in both St Louis and Nashville, rely on a small internal battery to start the engine automatically during a utility power outage. The battery needs to be charged all the time so it’s ready to go. To do this, the generator has a battery charger built inside, which draws power from your home's main electricity (that's the "AC" in the message – it stands for Alternating Current).

If there’s a problem and the generator can't get AC power to the charger, or if the charger isn’t working right, your generator will show the 1911 code. In plain terms: the battery may slowly lose power and, if not corrected, the generator might not start when you need backup power the most.

 

Why Does the 1911 Code Happen?

 

This code can happen for several reasons, and understanding them can help you or your technician fix the problem faster. Below are common causes experts at Hoffman Brothers see with generators in St Louis and Nashville:

  • Tripped Breaker: The circuit breaker powering the battery charger may have been accidentally switched off or tripped due to a power surge. This turns off the battery charger inside your generator.
  • Loose or Damaged Power Cord: Sometimes, the power cord connecting your home to the generator’s battery charger gets knocked loose (perhaps during routine yard maintenance), or the cord itself becomes damaged or worn out.
  • Power Outage or Maintenance: If your home loses utility power or if electrical work is being done, the charger also loses power. When that happens, the generator will alert you with this code after a short period.
  • Faulty Battery Charger: Occasionally, the actual battery charger inside the generator fails due to age, heat, moisture, or mechanical issues.

 

How to Check and Fix the 1911 Code

 

If you see the 1911 code on your generator, there are some basic steps you can take before calling a professional, like the specialists from Hoffman Brothers serving St Louis or Nashville:

  • Check the Circuit Breaker: Locate the breaker switch for your generator’s battery charger (usually found inside your home’s electrical panel, sometimes in the generator enclosure). Make sure it is in the "ON" position.
  • Inspect the Power Cord and Outlet: Ensure that the power cord going to the generator’s battery charger is securely plugged in and the outlet works. Plug another device (like a lamp) into the same outlet to test.
  • Look for Signs of Damage: Visually inspect the power cord, connections, and outlets for any obvious damage like frayed wires, burnt marks, or loose plugs.
  • Test Utility Power: Verify that your home or business is getting power where the generator is connected. Sometimes an unrelated issue (like a neighborhood power outage in St Louis or Nashville) will lead to this error.
If you’re comfortable with these checks and you still see the code, it’s time to contact a qualified technician. Battery chargers inside generators are complex, and improper repairs can cause bigger issues or void your warranty. Hoffman Brothers technicians are experienced with all Generac models and can safely address this type of issue.

 

What Happens If You Ignore the 1911 Code?

 

If this problem goes unfixed, the generator battery can drain completely. When that happens, the generator won’t be able to start automatically the next time your property loses power. This could leave your household or business unprotected during a blackout, which is especially critical during storms and high-demand periods in both St Louis and Nashville, where summer storms and winter ice can knock out power for hours or days.

In addition, letting a dead battery sit too long can permanently damage it, requiring a new battery, which costs more and leads to further downtime.

 

How to Prevent the 1911 Code in the Future

 

Prevention begins with regular maintenance. Some of the best ways homeowners and business owners in St Louis and Nashville can avoid the 1911 code include:

  • Scheduling routine maintenance checks with a trusted technician to look over wiring, connections, and breakers.
  • Keeping the area around your generator clear to prevent cords from being unplugged or damaged.
  • Making sure your home’s electrical system is in good shape, with no frequently tripping breakers or overloaded circuits.
  • Ensuring your generator receives a regular start-up/self-test weekly (most models do this automatically, but double-check with your installer).

Prompt attention to any error codes, especially one like 1911, will help guarantee your standby generator is always ready to protect your property whenever it’s needed. If you're unsure or ever feel uncomfortable troubleshooting electrical equipment, always contact a qualified team like those at Hoffman Brothers, serving both St Louis and Nashville, for reliable assistance.

Expert Generator Solutions Await!

Generator issues in St. Louis or Nashville? Our experts provide quick repairs and maintenance to keep you cool. Contact us today!

Request a quote

How to fix the 1911 Error on a Generac Generator?

 

Understanding and Fixing the 1911 Error on a Generac Generator

 

The 1911 Error on a Generac generator means the system has detected a high coolant temperature shutdown. This error shows that the engine got too hot and shut itself off to prevent damage. It's a safety feature built into every Generac unit. High coolant temperature can be caused by blocked airflow, low coolant levels, a faulty radiator fan, leaking hoses, or a failing water pump. Fixing this issue involves careful steps to find the cause and prevent it from happening again, whether you’re in St Louis or Nashville.

 

What To Do Immediately When 1911 Error Appears

 

  • Turn off the generator and let it cool down for at least 30 minutes before touching any parts. The engine and components will be extremely hot.
  • Remove the error: Press the OFF button on your control panel, wait, then press ENTER or RESET. If the code clears but returns when starting, proceed with the troubleshooting steps below.

 

Step-by-Step Troubleshooting to Fix the 1911 Error

 

  • Check Coolant Level: Open the generator panel and find the coolant reservoir, which is usually a translucent plastic bottle connected with hoses. Look for a "Full" or "Low" mark. If low, fill with the recommended coolant type in your owner's manual. Never open the radiator cap while the generator is hot.
  • Inspect for Coolant Leaks: Look for wet spots, puddles, or dried white residue under and around the generator, hoses, and radiator. If you see a leak, have it repaired before running the generator again.
  • Inspect Radiator and Fan: Check that nothing blocks the radiator (like leaves, grass, dust). Remove any debris carefully. Spin the fan by hand (when engine is off and cold); it should move freely. If not, the fan motor may be bad and needs professional service, whether you’re in St Louis or Nashville.
  • Look for Airflow Problems: Make sure the generator is not surrounded by walls, bushes, or other objects within three feet. These can trap heat and cause the error.
  • Check Radiator Cap: When the engine is cool, take off the radiator cap and inspect the rubber gasket for cracks. A faulty cap can let coolant escape as steam; replace if damaged.
  • Check for Faulty Water Pump: If the water pump is not circulating coolant, the generator will overheat. Listen for unusual noises when the engine starts. If you hear squealing or grinding, call a professional.
  • Thermostat Trouble: Rarely, the thermostat that controls coolant flow inside your generator can fail, causing high temperatures. This is a job for experienced technicians found locally in both St Louis and Nashville.

 

Testing After Troubleshooting

 

  • Once you address possible problems, refill coolant as needed and clear the code on your control panel.
  • Turn the generator to AUTO or MANUAL to restart. Let it run for 10–20 minutes. Watch for any new leaks, fan operation, and listen for unusual noises.
  • If the 1911 Error returns, or you see coolant dripping again, shut off the generator and contact a certified technician.

 

How to Prevent the 1911 Error in the Future

 

  • Keep the area around your Generac generator clean and clear.
  • Check coolant levels every 3–6 months, especially before severe weather events in places like St Louis and Nashville where storms can cause longer outages.
  • Have a professional perform annual maintenance to inspect the cooling system and fans, flush coolant as needed, check hoses for wear, and ensure all parts are in working order.

 

When to Call a Professional

 

  • If you find active leaks, can’t clear the code, or are uncomfortable handling generator parts, work only with licensed experts familiar with Generac units. Improper repairs could risk damage or void warranties.
  • Qualified teams in St Louis and Nashville can fix 1911 errors quickly and check your generator for any deeper issues, ensuring you have safe and reliable backup power.

 

Areas Of Expertise

We treat our people as our top priority so they'll treat you the same way. 100% Satisfaction, Every Time!

Air Conditioning

Providing air conditioning repairs, installation and maintenance for St Louis, MO and Nashville, TN. During the hot summers, call Hoffmann Brothers for all your AC repairs, replacement, and tuneup needs.

Electrical Repair

Hoffmann Brothers offers residential and commercial electrical services for St Louis homes and businesses. Lighting, outlets, panels, whole house fans, generators, and more. Call our licensed electricians today!

Heating Services

Need a furnace repair in St Louis or Nashville? Hoffmann Brothers can handle all your heating repairs, no matter the brand, including ductless mini-split systems. We also proudly offer heating system installations, and ongoing maintenance services.

Appliances

Hoffmann Brothers offers appliance repair services throughout St Louis, MO! Our experienced technicians are trained to work on all major brands of most home appliances including Dishwashers, Refrigerators & Freezers, Washing Machines & Dryers, and Ovens.

Plumbing Services

Hoffmann Brothers is your experienced Plumbing Company service both St Louis and Nashville. We offer plumbing repairs and installations, along with drain and sewer solutions.

Commercial Services

Do you need Mechanical or Commercial services for your St Louis or Nashville area business? We offer HVAC, Plumbing, Electrical (St Louis only), Indoor Air Quality, and more.

Water Heaters

Hoffmann Brothers is your professional water heater contractors for both Nashville, TN and St Louis, MO. We provide hot water heater installation, repair, and maintenance for both standard and tankless systems.

Drains & Sewers

Hoffmann Brothers is your Nashville and St Louis area drain Plumber. We provide drain cleaning and clearing and much more. Trust our drain experts to fix your clogged sink or toilet quickly and efficiently.

What could be causing the 1911 error code on a Generac Generator?

 

What Causes the 1911 Error Code on a Generac Generator?

 

The 1911 error code on a Generac generator is almost always an indication of a communication problem between the generator’s main controller and the Automatic Transfer Switch (ATS). To put it simply, your generator is trying to “talk” to the switch that tells it when to turn on during a power outage, but the message is not getting through. This issue stops the generator from starting automatically as intended, leaving your property unprotected during a power failure.

 

Understanding the Components Involved

 

There are two primary parts at play:

  • Main Controller: This is like the brain of your Generac generator. It manages operations, checks for power outages, and sends signals to start or stop the unit.
  • Automatic Transfer Switch (ATS): This device senses when your regular power supply (from the grid) goes out. When it does, the ATS tells the generator to start, and then safely switches your property over to backup generator power. When regular power returns, it reverses the process.

If your generator is located in St Louis or Nashville, this setup is especially crucial because both areas can experience severe storms or outages.

 

Common Causes of the 1911 Error

 

Several specific factors can disrupt communication and trigger the 1911 code:

  • Loose or Disconnected Wires: Over time, wires that connect the generator and ATS can become loose due to vibration, temperature changes, or poor initial installation. If any wire is not firmly connected, the signal gets interrupted.
  • Corrosion or Water Damage: In both St Louis and Nashville, humidity or heavy rain can cause water to get inside the panels or conduit. Moisture can corrode connectors or short out the communication lines, severing the connection.
  • Rodent or Insect Damage: Mice, squirrels, or insects have been known to chew on wiring or nest inside control panels, particularly in areas with cold winters or wooded surroundings common in and around St Louis or Nashville. This can break or damage the small communication wires.
  • Faulty Automatic Transfer Switch (ATS): The ATS itself may malfunction due to an internal failure such as a bad relay, failed communication port, or power surge. These failures are often not outwardly visible without electrical testing.
  • Controller Board Problems: The main controller inside the generator (the control board) can develop problems, especially after lightning storms, power surges, or simply due to age. If the board fails, it can stop sending or receiving messages from the ATS.
  • Incorrect Generator or ATS Programming: Occasionally, the generator or switch may have incorrect settings or older software that makes them incompatible. If the models don’t match up, or settings are incorrect, they won’t communicate properly.
  • Damaged Communication Cable: The physical cable running between the generator and the transfer switch could be pinched, cut, or internally broken. Lawnmowers, construction activity, or shifting soil (which is more common in newer developments in St Louis and Nashville) can all affect buried or surface-installed wires.

 

Why Addressing the 1911 Error Is Important

 

When the 1911 code appears, the key problem is your generator will not respond to outages automatically. This means if you lose power, your home or business in St Louis or Nashville will not have backup electricity unless you start the generator manually—if it will even allow that.

This is especially critical for people who rely on medical equipment, have perishable goods, or want to avoid freezing or sweltering temperatures during seasonal storms.

 

In Summary

 

The 1911 error code on Generac generators means communication is lost between the generator and the automatic transfer switch. Root causes include loose or corroded wiring, water damage, pest activity, failure in either the switch or controller, damaged cables, or mismatched settings. These causes stop your generator from automatically keeping your property in St Louis or Nashville powered during an outage. If this error appears, it signals that your backup protection isn’t working as intended.

SERVING

St. Louis & Nashville Areas

Brentwood, MO
1025 Hanley Industrial
Brentwood, MO 63144

Nashville, TN
45 Willow St.
Nashville, TN 37210

Call Our St. Louis Office

Call Our Nashville Office

Nashville Location

(615) 515-3015

Read More

Kohler Generator Code 21 Error Code Explained: Meaning, Causes & Fixes

Discover what Kohler Generator Code 21 means, its common causes, and how to fix it. Get quick troubleshooting tips to resolve this error and keep your generator running smoothly.

Kohler Generator Code 24 Error Code Explained: Meaning, Causes & Fixes

Discover what Kohler Generator Code 24 means, common causes behind this error, and step-by-step solutions to fix it. Quickly troubleshoot your generator with our expert guide.

Kohler Generator Accy PwrOver Warning Error Code Explained: Meaning, Causes & Fixes

Discover what the Kohler Generator "Accy PwrOver Warning" error code means, its common causes, and how to fix it. Get clear, step-by-step solutions to keep your generator running smoothly.

Cummins Generator SPN 175 FMI 3 Error Code Explained: Meaning, Causes & Fixes

Discover the meaning, common causes, and solutions for the Cummins Generator SPN 175 FMI 3 error code. Learn how to diagnose and fix this issue to keep your generator running smoothly.

Kohler Generator Code 23 Error Code Explained: Meaning, Causes & Fixes

Discover what Kohler Generator Code 23 means, common causes behind the error, and effective solutions to fix it. Get your generator running smoothly with these expert tips.

Cummins Generator SPN 284 FMI 4 Error Code Explained: Meaning, Causes & Fixes

Discover the meaning, common causes, and solutions for Cummins Generator SPN 284 FMI 4 error code. Quickly troubleshoot and resolve this generator issue with our expert guide.