Discover the meaning behind Generac Generator 1910 error code, including common causes and effective fixes. Get your generator running smoothly with this easy guide.

Head of Content, D. Gorenko
Updated June, 5
When a Generac standby generator displays the 1910 error code, it means "Overcrank." Simply put, the generator tried and failed to start several times in a row and then automatically shut itself down to avoid damaging the engine. This error is common in both home and business generators – and it's a safety feature designed to protect your equipment.
The generator attempts to start (crank) for a pre-set number of cycles if it senses an outage or is asked to run. If it does not start within these attempts—usually after three tries—it posts the 1910 code and locks itself out. This stops further cranking, which could drain the battery or harm the starter motor.
There could be several reasons why your Generac generator in St Louis or Nashville isn’t starting properly. The most common causes are:
If your Generac generator shows a 1910 code, here are practical actions anyone in St Louis or Nashville can take before calling in a professional:
If these steps don’t resolve the problem, it's best not to keep trying to start the generator. Ongoing failed starts can cause further damage. At this stage, professionals who serve St Louis and Nashville can diagnose and safely repair more complex issues.
When a Generac generator in St Louis or Nashville needs repair for a 1910 error, experts follow careful steps:
Once the problem is located, professionals repair or replace faulty parts, clear the code using the control panel, and then test the generator to ensure it starts and runs reliably. After repairs, it’s also common to check for and update any software or firmware associated with the controller panel to prevent recurrence.
To greatly reduce the chance of a 1910 code on your Generac, regular preventative maintenance is important:
A 1910 error code on your Generac generator means the engine has attempted to start and failed several times, so the system locked itself out to avoid damage. This is often a warning that there’s a fuel, battery, electrical, or mechanical problem. Homeowners and business owners in St Louis or Nashville can take some simple initial checks—fuel, battery, and reset—before seeking professional help for deeper issues or repairs. Preventative maintenance is the best way to avoid overcrank errors and keep your backup power ready when it’s needed most.

Generator issues in St. Louis or Nashville? Our experts provide quick repairs and maintenance to keep you cool. Contact us today!
Request a quote
When you see a 1910 Error (Undervoltage Shutdown – Auxiliary Shutdown) on your Generac generator, it means the generator has shut down because it detected an unsafe low voltage condition, often linked to external wiring, device loads, or transfer switch connections. This is a safety feature to protect the system from electrical damage. Follow these detailed steps to resolve this error safely and effectively.
If you’re in the St Louis or Nashville area, start by considering if your home or business recently experienced a power outage or flickering lights. The transfer switch is a device that switches your electrical source from the utility grid to your generator and back. A malfunction in the transfer switch can cause undervoltage errors. Listen for unusual clicking or buzzing from the switch, and visually inspect for burnt smells or scorch marks.
Make sure your property has a stable incoming power supply. Sometimes, the problem is with the electric utility and not your generator. Use a basic voltage meter (multimeter) to check your main power lines if comfortable, or simply verify if major appliances are working as expected. Inconsistent power will confuse your generator’s electrical sensing circuits and cause this shutdown code.
Turn off the generator’s main breaker before doing any checks, for safety. Open the generator’s exterior panel using the manufacturer’s instructions. Look at all visible wires, especially the larger ones entering and leaving the switch. Check for:
If you see anything missing or damaged, do not attempt to repair it yourself; wiring mistakes are dangerous. In St Louis and Nashville, professional technicians from a licensed provider can diagnose and repair faulty electrical connections.
Sometimes the error results from issues inside the generator itself, such as:
If you’re not familiar with these parts, it’s safest to stop and call for service from a technician who regularly works with Generac generators in St Louis or Nashville.
Overloading your generator can trigger a 1910 error. Go inside and unplug unnecessary appliances or heavy electrical devices plugged in while the generator was running. Wait a few minutes, then clear the error as described below and start the generator again with reduced load.
To reset the error:
If the code clears, restore power by turning the main breaker back ON, and observe the system.
If you have followed all the above steps and the 1910 error persists:
Generators are complex machines, and safe repairs require knowledge and special equipment. If you’re located near St Louis or Nashville, technicians at established service companies like Hoffman Brothers can quickly pinpoint and fix the problem, minimizing downtime and protecting your property.
To fix a 1910 error on your Generac generator: start by checking for recent outages, verify utility power and transfer switch functionality, inspect visible wires and internal components carefully, and reduce any overload. Always reset the generator with the correct process, and call a professional if the error doesn’t clear. Safety first—if you’re ever unsure, contact a trained technician in St Louis or Nashville for help.
We treat our people as our top priority so they'll treat you the same way. 100% Satisfaction, Every Time!
Providing air conditioning repairs, installation and maintenance for St Louis, MO and Nashville, TN. During the hot summers, call Hoffmann Brothers for all your AC repairs, replacement, and tuneup needs.
Hoffmann Brothers offers residential and commercial electrical services for St Louis homes and businesses. Lighting, outlets, panels, whole house fans, generators, and more. Call our licensed electricians today!
Need a furnace repair in St Louis or Nashville? Hoffmann Brothers can handle all your heating repairs, no matter the brand, including ductless mini-split systems. We also proudly offer heating system installations, and ongoing maintenance services.
Hoffmann Brothers offers appliance repair services throughout St Louis, MO! Our experienced technicians are trained to work on all major brands of most home appliances including Dishwashers, Refrigerators & Freezers, Washing Machines & Dryers, and Ovens.
Hoffmann Brothers is your experienced Plumbing Company service both St Louis and Nashville. We offer plumbing repairs and installations, along with drain and sewer solutions.
Do you need Mechanical or Commercial services for your St Louis or Nashville area business? We offer HVAC, Plumbing, Electrical (St Louis only), Indoor Air Quality, and more.
Hoffmann Brothers is your professional water heater contractors for both Nashville, TN and St Louis, MO. We provide hot water heater installation, repair, and maintenance for both standard and tankless systems.
Hoffmann Brothers is your Nashville and St Louis area drain Plumber. We provide drain cleaning and clearing and much more. Trust our drain experts to fix your clogged sink or toilet quickly and efficiently.
The 1910 error code on a Generac generator means there’s a problem with the generator’s battery charger. To put it simply, this code shows up when the generator is either not receiving power to charge its battery, or the internal battery charger isn’t working as intended. The result is a battery that’s not being kept charged, which can prevent the generator from starting up when you need it most. Whether you’re in St Louis or Nashville, battery charger issues are a leading cause of generator startup problems, especially in climates with big temperature swings.
The generator’s battery charger is a small device—either built-in or attached—that keeps the starting battery charged. This charger usually works off your home or building’s incoming electrical power. When everything’s working, the generator battery is always topped off and ready to go. If the charger stops functioning, the battery can lose power slowly over time, and the generator won’t start—even if everything else is working perfectly.
The 1910 error code is common in areas with big differences between hot summers and cold winters, such as St Louis and Nashville. Variations in temperature stress battery components, wiring, and chargers. Humidity and storms increase the risk of electrical surges that can blow fuses or damage charging circuits. In both residential neighborhoods and commercial sites, the battery is the heart of the generator startup process. Missing this error can mean no backup power when it’s needed most—during storms, ice, or grid failures.
In summary, the 1910 error code on a Generac generator signals a problem with the battery charger or related parts. The error means that, unless something changes, the generator’s battery will eventually go dead, and the unit won’t be able to start up when utility power goes out. Home and business owners in both St Louis and Nashville rely on these chargers to keep backup power ready year-round, so understanding the meaning behind the code is key to keeping your generator ready for any emergency.
SERVING
Brentwood, MO
1025 Hanley Industrial
Brentwood, MO 63144
Nashville, TN
45 Willow St.
Nashville, TN 37210

St Louis Location
(314) 664-3011
St Louis Location
1025 Hanley Industrial Brentwood, MO 63144
Nashville Location
(615) 515-3015
Nashville Location
45 Willow St Nashville, TN 37210
Discover what Kohler Generator Code 21 means, its common causes, and how to fix it. Get quick troubleshooting tips to resolve this error and keep your generator running smoothly.
Discover what Kohler Generator Code 24 means, common causes behind this error, and step-by-step solutions to fix it. Quickly troubleshoot your generator with our expert guide.
Discover what the Kohler Generator "Accy PwrOver Warning" error code means, its common causes, and how to fix it. Get clear, step-by-step solutions to keep your generator running smoothly.
Discover the meaning, common causes, and solutions for the Cummins Generator SPN 175 FMI 3 error code. Learn how to diagnose and fix this issue to keep your generator running smoothly.
Discover what Kohler Generator Code 23 means, common causes behind the error, and effective solutions to fix it. Get your generator running smoothly with these expert tips.
Discover the meaning, common causes, and solutions for Cummins Generator SPN 284 FMI 4 error code. Quickly troubleshoot and resolve this generator issue with our expert guide.