/generator-error-codes

Generac Generator 1908 Error Code Explained: Meaning, Causes & Fixes

Learn what Generac Generator 1908 error code means, its common causes, and how to fix it. Get simple troubleshooting tips to restore your generator’s performance.

Reviewed by Content Team

Head of Content, D. Gorenko

Updated June, 5

What does the 1908 error code on Generac a Generator mean?

 

What the 1908 Error Code Means on a Generac Generator

 

When you see the 1908 error code displayed on your Generac generator, it means that the generator’s controller is alerting you about a missed exercise event. In simple terms, the generator was scheduled to run a self-test or maintenance cycle at a specific time, but for some reason, it didn’t complete that test as planned. The 1908 code is not telling you that something is broken or unsafe, but it is letting you know that your generator missed an important check-up, which could affect its reliability in the future.

 

Understanding Missed Exercise Events

 

Most home and business standby generators, including Generac models, are programmed to run regular “exercise” cycles. This is like a weekly or bi-weekly warm-up where the generator turns on by itself and runs for a short time. The purpose of these exercise cycles is to:

  • Keep the engine and generator parts lubricated and in working condition.
  • Check basic functions so you know the generator is ready if the power goes out.
  • Alert you to problems early, rather than finding out during an actual power outage.

The generator controller keeps track of when these exercises are supposed to occur. If something interrupts this—such as a power issue, changed schedule, dead battery, or even accidentally turning off the generator—the controller will generate the 1908 error code.

 

Common Reasons for the 1908 Error Code

 

Several different things could cause this code to appear, including:

  • The generator wasn’t in AUTO mode, so it never started its exercise cycle.
  • The scheduled exercise time was changed or deleted, either intentionally or by mistake.
  • The battery was too weak or dead at the time the test was supposed to run.
  • The generator was being serviced or shut down during the scheduled test.
  • A power loss or electrical issue prevented the controller from keeping its schedule.

In places with big seasonal changes like St Louis or the unpredictable weather of Nashville, any of these situations can occur—and it’s easy to overlook a missed self-test.

 

How to Fix the 1908 Error Code

 

If you see this code, you don’t need to panic. Here’s what you can do:

  • First, make sure the generator switch or controller is set to AUTO. If it’s not in AUTO, put it back so it can resume its schedule.
  • Look at the controller screen and check when the next exercise is scheduled. If it’s missing, you’ll need to reprogram it. Consult your manual or reach out to a local technician in St Louis or Nashville for help.
  • Press the ENTER or CLEAR button on the controller panel (if your model has one) to acknowledge and clear the alert. This does not fix underlying issues but lets you confirm the message.
  • Test the generator by manually starting its exercise mode. This can be done from the control panel and allows you to watch and listen for any problems.
  • If the generator won't start during a manual exercise, check the battery and main circuit breaker. A dead battery is a common cause, especially in homes and businesses in St Louis where long periods of inactivity can drain the battery.

If you’re ever unsure—or if the code keeps coming back—call a generator service specialist. In the St Louis and Nashville area, skilled technicians can inspect and test your generator, reset the controller, and make sure future exercise events go as planned.

 

Why Regular Exercise Cycles Are Important

 

Ignoring the 1908 code isn’t recommended, even though it’s not an emergency. Regular generator self-tests prevent engine problems, fuel issues, and failure to start when you need backup power most. In climates like those in St Louis and Nashville, winter cold or summer storms can cause power outages, so you want your generator to be ready—and regular exercise is essential for reliability.

 

When to Call a Professional

 

If these steps don’t clear the code or if you notice anything unusual during the manual test (such as strange noises, smoke, or repeated failure to start), it’s best to schedule a service visit. Regular maintenance by a skilled technician in St Louis or Nashville will help you avoid future issues and keep your generator ready for emergencies.

 

Expert Generator Solutions Await!

Generator issues in St. Louis or Nashville? Our experts provide quick repairs and maintenance to keep you cool. Contact us today!

Request a quote

How to fix the 1908 Error on a Generac Generator?

 

Understanding and Fixing the 1908 Error on a Generac Generator

 

A 1908 error on your Generac generator is commonly labeled as a “Low Voltage – Sense Loss” issue. This error means that the generator’s control system is not detecting the correct voltage where it should, usually due to a wiring, connection, or internal component issue. If you’re based in St Louis or Nashville, knowing how to troubleshoot and when to call a professional like Hoffman Brothers will keep your home or business protected during outages.

 

What Does the 1908 Error Mean?

 

This code essentially signals that your generator’s brains aren’t seeing the voltage they’re supposed to at the main controller’s “sense line,” which helps regulate and monitor power. It can be caused by:

  • A disconnected or broken wire
  • A blown fuse
  • A controller circuit board issue
  • Problems with the generator’s alternator

Before you start, always put safety first. If you’re uncomfortable with electricity, do not proceed. Otherwise, turn off the generator and shut off power from the main source before opening the unit.

 

Step-by-Step: Troubleshooting the 1908 Error

 

  • Reset the Generator: Occasionally, a quick reset solves temporary glitches. Using the control panel, press “Off,” wait 30 seconds, then press “Auto.” Start the generator. If the error remains, move to the next step.
  • Inspect Visual Connections: Open your generator’s enclosure. Check for any obviously loose, disconnected, or damaged wires, particularly at the control board (the main electronic “brain” inside the panel) and fuses. Use a flashlight to look closely. In both St Louis and Nashville climates, temperature swings can cause wires to loosen or corrosion on contacts, so look for any green or white buildup.
  • Check the Fuses: Most Generac generators have small fuses on the control board. They’re like the fuses in your car. If one looks burnt out or blackened, it likely needs replacing. You can buy replacements at a hardware store, but make sure the replacement has the same voltage and amperage rating as the original.
  • Examine the Battery and Battery Connections: A weak battery, corroded terminals, or loose battery wiring causes numerous error codes, including 1908. Make sure the battery terminals are shiny and tightly connected. If they’re crusty, clean them with a wire brush. In cold winters in St Louis or stormy seasons in Nashville, batteries fail fast—regular checks help prevent this.
  • Look at the Control Board: If you’re comfortable, check the small, delicate circuit board for burn marks, cracked solder joints, or obvious damage. If any are present, the control board may need replacement, which should be done by a professional.
  • Test Voltage Output (Advanced): If you have safety gloves and a multimeter, check for expected voltage at the main output lugs and at the sense lead (usually labeled on the wiring diagram found in your generator’s manual or on the enclosure door). If you don’t know how, don’t risk it — improper checks can damage the generator or cause injury. This step is safer left to technicians from a reputable company such as Hoffman Brothers in both St Louis and Nashville.

 

What to Do If These Steps Don’t Work

 

If the error code persists after the above checks, the generator may have a deeper internal issue such as a faulty controller, alternator malfunction, or significant wiring defect requiring specialized tools. At this point:

  • Do not continue trying to start the generator, as repeated resets could make the problem worse or damage internal parts.
  • Write down the model and serial number and any steps you’ve already taken. This information will help professionals diagnose faster.
  • Contact a certified Generac repair technician. In the St Louis or Nashville area, Hoffman Brothers has trained professionals who service Generac generators for both homes and businesses quickly and safely.

 

Maintaining Your Generator to Prevent Future 1908 Errors

 

Routine checks are the best prevention. Keep wiring tight and free of corrosion. Run your generator for a shorter “exercise” session every week or two, so minor issues can be spotted before they become emergencies. Check the owner’s manual for maintenance schedules, fuse specifications, and troubleshooting guides for your specific model. If you’re in St Louis or Nashville, seasonal weather can impact battery and wiring life, so increase inspection frequency during extreme conditions.

 

In summary, fixing the 1908 error on a Generac generator involves basic resets first, then checking fuses, wiring, battery, and finally calling professionals if the problem remains. Always prioritize safety and don’t hesitate to contact local experts for help.

Areas Of Expertise

We treat our people as our top priority so they'll treat you the same way. 100% Satisfaction, Every Time!

Air Conditioning

Providing air conditioning repairs, installation and maintenance for St Louis, MO and Nashville, TN. During the hot summers, call Hoffmann Brothers for all your AC repairs, replacement, and tuneup needs.

Electrical Repair

Hoffmann Brothers offers residential and commercial electrical services for St Louis homes and businesses. Lighting, outlets, panels, whole house fans, generators, and more. Call our licensed electricians today!

Heating Services

Need a furnace repair in St Louis or Nashville? Hoffmann Brothers can handle all your heating repairs, no matter the brand, including ductless mini-split systems. We also proudly offer heating system installations, and ongoing maintenance services.

Appliances

Hoffmann Brothers offers appliance repair services throughout St Louis, MO! Our experienced technicians are trained to work on all major brands of most home appliances including Dishwashers, Refrigerators & Freezers, Washing Machines & Dryers, and Ovens.

Plumbing Services

Hoffmann Brothers is your experienced Plumbing Company service both St Louis and Nashville. We offer plumbing repairs and installations, along with drain and sewer solutions.

Commercial Services

Do you need Mechanical or Commercial services for your St Louis or Nashville area business? We offer HVAC, Plumbing, Electrical (St Louis only), Indoor Air Quality, and more.

Water Heaters

Hoffmann Brothers is your professional water heater contractors for both Nashville, TN and St Louis, MO. We provide hot water heater installation, repair, and maintenance for both standard and tankless systems.

Drains & Sewers

Hoffmann Brothers is your Nashville and St Louis area drain Plumber. We provide drain cleaning and clearing and much more. Trust our drain experts to fix your clogged sink or toilet quickly and efficiently.

What could be causing the 1908 error code on a Generac Generator?

 

What Does the 1908 Error Code on a Generac Generator Mean?

 

If you have a Generac generator in your home or business in St. Louis or Nashville, and you see the 1908 error code, it means the generator has detected a low voltage from the utility power source in your area. In simpler terms, your generator is noticing that the electricity coming into your building from your utility company has dropped below the normal range. This voltage drop isn’t coming from your generator—it’s coming from your main electricity supply. The generator is programmed to watch for this problem so it can protect electrical devices in your building or start working if the power gets bad enough.

 

Main Causes Behind the 1908 Error Code

 

This code isn’t a sign of a problem with the generator’s own engine or internal parts. Instead, it points to an issue with the main power coming from your utility company’s electrical grid. Here’s what can trigger the 1908 error:

  • Utility Grid Problems: This is the most common reason for a 1908 code in places like St. Louis and Nashville. Bad weather, damaged equipment, or problems with the electrical supply can cause the voltage from the utility company to drop. This is sometimes called a “brownout,” and it means the amount of electricity being delivered is less than what’s needed.
  • Wiring or Breaker Issues: If there’s a loose connection, broken wire, or a faulty breaker between your electric meter and the point where the generator measures incoming voltage, the reading might be lower than it should be. Corrosion, rodent damage, or old wiring—especially in older homes and buildings around St. Louis or Nashville—can all contribute.
  • Heavy Load Situations: If too many powerful appliances or machines are running in your building at the same time, they can pull more electricity than your supply can handle. This could cause the voltage to drop, and the generator will sense this and issue the 1908 alert.
  • Poor Utility Transformer Performance: The transformer is a device mounted on utility poles or in ground-level metal boxes; it changes the voltage of electricity so it’s safe for use in homes and businesses. If a transformer is malfunctioning or overloaded in your part of St. Louis or Nashville, low voltage can occur at your property, which the generator will detect.
  • Seasonal Demand: In both St. Louis and Nashville, hot summers and cold winters can stress the electrical grid, sometimes causing temporary low voltage conditions that your generator will identify.

 

Why the Generator Shows the 1908 Code

 

The generator’s job is to protect your home or business by monitoring utility power. Modern Generac generators are smart—they continuously check the voltage level coming from your main utility line. If the voltage drops below a set level and stays there long enough, your generator triggers the 1908 code so you know there’s a potential risk to your electronic devices or systems. In many systems, if the voltage goes too low or stays bad, the generator might even switch on automatically to make sure your building has safe, stable power.

 

Is 1908 Code a Generator Breakdown?

 

No, the 1908 code doesn’t mean your generator has broken down. It’s a warning message telling you there’s a utility power quality problem—that the voltage from the street isn’t what it should be for safe operation. The code means your generator is doing its job protecting your property and alerting you to outside issues.

 

Extra Context for St. Louis and Nashville Owners

 

Homes and businesses in both St. Louis and Nashville can be affected by local utility issues, especially during storms, construction, or periods of high demand. Knowing that the 1908 code almost always relates to outside power—not to your generator itself—can help you avoid unnecessary worry. If the issue persists, it’s generally tied to what’s happening on the grid serving your neighborhood.

 

SERVING

St. Louis & Nashville Areas

Brentwood, MO
1025 Hanley Industrial
Brentwood, MO 63144

Nashville, TN
45 Willow St.
Nashville, TN 37210

Call Our St. Louis Office

Call Our Nashville Office

Nashville Location

(615) 515-3015

Read More

Kohler Generator Code 21 Error Code Explained: Meaning, Causes & Fixes

Discover what Kohler Generator Code 21 means, its common causes, and how to fix it. Get quick troubleshooting tips to resolve this error and keep your generator running smoothly.

Kohler Generator Code 24 Error Code Explained: Meaning, Causes & Fixes

Discover what Kohler Generator Code 24 means, common causes behind this error, and step-by-step solutions to fix it. Quickly troubleshoot your generator with our expert guide.

Kohler Generator Accy PwrOver Warning Error Code Explained: Meaning, Causes & Fixes

Discover what the Kohler Generator "Accy PwrOver Warning" error code means, its common causes, and how to fix it. Get clear, step-by-step solutions to keep your generator running smoothly.

Cummins Generator SPN 175 FMI 3 Error Code Explained: Meaning, Causes & Fixes

Discover the meaning, common causes, and solutions for the Cummins Generator SPN 175 FMI 3 error code. Learn how to diagnose and fix this issue to keep your generator running smoothly.

Kohler Generator Code 23 Error Code Explained: Meaning, Causes & Fixes

Discover what Kohler Generator Code 23 means, common causes behind the error, and effective solutions to fix it. Get your generator running smoothly with these expert tips.

Cummins Generator SPN 284 FMI 4 Error Code Explained: Meaning, Causes & Fixes

Discover the meaning, common causes, and solutions for Cummins Generator SPN 284 FMI 4 error code. Quickly troubleshoot and resolve this generator issue with our expert guide.