Learn what Generac Generator error code 1906 means, its common causes, and step-by-step solutions to fix it. Get your generator running smoothly with this comprehensive guide.

Head of Content, D. Gorenko
Updated June, 5
If your Generac generator is displaying a 1906 error code, this means “Undervoltage Alarm – Shutdown.” In simple terms, the generator has detected that the electricity it is producing (specifically, the voltage) has dropped below the acceptable range for a certain amount of time. To protect your equipment and keep anyone using the power safe, the generator stops running until the problem is fixed.
Every home or business electrical system in St Louis and Nashville operates within a specific voltage range—think of voltage as electrical “pressure.” Too little pressure (low voltage) can make lights dim, cause appliances to malfunction, or even damage sensitive electronics. Generac generators closely monitor their own voltage output so they don’t supply power that could be unsafe or unreliable.
When your Generac generator detects that it’s supplying less voltage than it should for a period (often measured in seconds), it throws the 1906 code and automatically shuts off. This is a built-in safety feature designed to avoid dangerous situations and prevent further damage.
A 1906 code often means there’s a mechanical or electrical concern that needs an expert’s attention. If you’ve performed the basic steps above and the error keeps coming back, the issue could be with the AVR, alternator, or the internal engine—areas that are best handled by a trained generator technician. In regions like St Louis and Nashville, trained professionals can accurately assess, repair, and thoroughly test the generator to make sure it’s safe to use.
The 1906 error code on a Generac generator means the unit has shut itself down due to low voltage, a key safety measure. It protects your home or business in St Louis and Nashville from the dangers and inconveniences caused by unstable electricity. Common problems include overloaded circuits, engine or component failures, or electrical connections issues. After following simple troubleshooting steps, professional repair is usually necessary to fix the root cause and to prevent recurring shutdowns. Consistent preventative maintenance remains the best way to ensure your generator remains reliable whenever you need backup power.

Generator issues in St. Louis or Nashville? Our experts provide quick repairs and maintenance to keep you cool. Contact us today!
Request a quote
When a Generac generator displays the 1906 error, it is signaling a rotor loss of field alarm. This means the generator’s control system has detected that the generator’s rotor—which is a spinning part inside the engine necessary to make electricity—is no longer getting the magnetism it needs to work. This is a serious issue because the generator can't produce electricity correctly or safely until this is fixed. In many homes and businesses in St Louis and Nashville, reliable standby power is essential, so addressing the 1906 error promptly is critical.
Before starting, always turn off the generator and its main circuit breaker for safety. If you don’t feel comfortable, or if your generator is still under warranty, always contact a qualified professional such as the local team in St Louis or Nashville for help.
If the above steps do not resolve the error, the issue may be deep within the generator's electrical system, requiring special diagnostic tools and expertise. At that point, it is best to contact qualified technicians serving St Louis or Nashville for in-depth troubleshooting and repairs. Continuing to run a generator with a 1906 error can risk further equipment damage and personal safety.
Regular generator maintenance is key. This includes:
With these steps, anyone in St Louis or Nashville can approach fixing the 1906 error on their Generac generator with confidence, ensuring restored power and peace of mind.
We treat our people as our top priority so they'll treat you the same way. 100% Satisfaction, Every Time!
Providing air conditioning repairs, installation and maintenance for St Louis, MO and Nashville, TN. During the hot summers, call Hoffmann Brothers for all your AC repairs, replacement, and tuneup needs.
Hoffmann Brothers offers residential and commercial electrical services for St Louis homes and businesses. Lighting, outlets, panels, whole house fans, generators, and more. Call our licensed electricians today!
Need a furnace repair in St Louis or Nashville? Hoffmann Brothers can handle all your heating repairs, no matter the brand, including ductless mini-split systems. We also proudly offer heating system installations, and ongoing maintenance services.
Hoffmann Brothers offers appliance repair services throughout St Louis, MO! Our experienced technicians are trained to work on all major brands of most home appliances including Dishwashers, Refrigerators & Freezers, Washing Machines & Dryers, and Ovens.
Hoffmann Brothers is your experienced Plumbing Company service both St Louis and Nashville. We offer plumbing repairs and installations, along with drain and sewer solutions.
Do you need Mechanical or Commercial services for your St Louis or Nashville area business? We offer HVAC, Plumbing, Electrical (St Louis only), Indoor Air Quality, and more.
Hoffmann Brothers is your professional water heater contractors for both Nashville, TN and St Louis, MO. We provide hot water heater installation, repair, and maintenance for both standard and tankless systems.
Hoffmann Brothers is your Nashville and St Louis area drain Plumber. We provide drain cleaning and clearing and much more. Trust our drain experts to fix your clogged sink or toilet quickly and efficiently.
The 1906 error code on a Generac generator indicates an issue related to the generator’s overspeed protection system. When this error appears, it means the generator’s engine has been detected running faster than its normal, safe speed. This is a protective shutdown code, designed to prevent further engine damage. If you see a 1906 error, the generator’s control board has shut down the system because it sensed that the engine speed exceeded the allowable threshold during operation.
Overspeed occurs when the engine inside your generator runs faster than the recommended number of revolutions per minute (RPM). Generac generators for home or business use in St Louis and Nashville are generally designed to run at either 1800 or 3600 RPM, depending on the model. If the engine runs above this speed by a certain margin, it can cause mechanical problems, excessive wear, or even catastrophic failure. That's why the control system stops the engine to protect itself and your property.
There are several reasons why your Generac generator might sense overspeed and display the 1906 code. Experienced technicians in St Louis and Nashville look at these common possibilities:
Generac generators in climates like those found in St Louis and Nashville can also be affected by extreme temperature swings, electrical storms, and even wildlife like rodents that chew through sensor wires. Environmental factors may indirectly lead to a 1906 error by introducing faults in critical components or connections needed to monitor engine speeds properly.
In brief, the 1906 error code on your Generac generator is almost always related to engine overspeed detection—either because the engine truly sped up too much or the system thinks it did, due to faulty signals or component issues. Whether you’re experiencing it in St Louis or Nashville, the root causes most often fall into the categories of sensor malfunction, control board error, wiring faults, loss of proper load, mechanical governor failures, incorrect frequency settings, or fuel problems. Understanding each possible cause can help you communicate clearly with service professionals and better prepare for necessary inspections and repairs.
SERVING
Brentwood, MO
1025 Hanley Industrial
Brentwood, MO 63144
Nashville, TN
45 Willow St.
Nashville, TN 37210

St Louis Location
(314) 664-3011
St Louis Location
1025 Hanley Industrial Brentwood, MO 63144
Nashville Location
(615) 515-3015
Nashville Location
45 Willow St Nashville, TN 37210
Discover what Kohler Generator Code 21 means, its common causes, and how to fix it. Get quick troubleshooting tips to resolve this error and keep your generator running smoothly.
Discover what Kohler Generator Code 24 means, common causes behind this error, and step-by-step solutions to fix it. Quickly troubleshoot your generator with our expert guide.
Discover what the Kohler Generator "Accy PwrOver Warning" error code means, its common causes, and how to fix it. Get clear, step-by-step solutions to keep your generator running smoothly.
Discover the meaning, common causes, and solutions for the Cummins Generator SPN 175 FMI 3 error code. Learn how to diagnose and fix this issue to keep your generator running smoothly.
Discover what Kohler Generator Code 23 means, common causes behind the error, and effective solutions to fix it. Get your generator running smoothly with these expert tips.
Discover the meaning, common causes, and solutions for Cummins Generator SPN 284 FMI 4 error code. Quickly troubleshoot and resolve this generator issue with our expert guide.