Discover the meaning, common causes, and effective solutions for Generac Generator 1903 error code. Quickly troubleshoot and resolve 1903 errors with this comprehensive guide.

Head of Content, D. Gorenko
Updated June, 5
When your Generac generator displays the 1903 error code, it is indicating an “Under-speed” or “RPM Sense Loss” fault. In simple terms, this means that the generator's engine is not running at the correct speed, or the control system is unable to detect how fast the motor is spinning. Generators need to run at a specific speed to produce the right amount of electricity (measured in hertz); when they slow down, speed up unexpectedly, or lose the ability to detect their own speed, it can result in problems with power output or even damage sensitive appliances.
A 1903 fault usually occurs because:
When the 1903 code appears on your Generac generator, you might notice:
If you see the 1903 fault code, here are steps you can take before calling a technician:
Gasoline, propane, or natural gas generators can pose safety hazards such as electric shock, fire, or gas leaks. The 1903 error involves many components—fuel system, wires, electronic boards, and moving parts. An experienced technician will:
Regular generator maintenance—changing filters, checking fuel supply, cleaning electrical connections, and running periodic self-tests—greatly reduces the chance of experiencing a 1903 error code. Local weather in St Louis and humidity in Nashville may demand even more frequent checks for corrosion or debris. Scheduling annual professional inspections and promptly addressing any engine trouble is the best way to keep your generator reliable.
The 1903 error code on a Generac generator means the engine is not running at the right speed or the system can’t detect its speed. This often involves minor sensor or wiring issues, but can be caused by deeper engine or fuel problems. While there are a few quick things you can check yourself, it’s safest to call in a certified generator specialist, especially for residents and businesses in regions like St Louis and Nashville. Regular service and prompt attention to warning codes will protect your backup power source for years to come.

Generator issues in St. Louis or Nashville? Our experts provide quick repairs and maintenance to keep you cool. Contact us today!
Request a quote
The 1903 error on a Generac generator is an “Undervoltage” alarm, which means your generator detected that the voltage it’s producing has dropped below the expected safe level. This typically happens due to three main reasons: low generator output because of a mechanical problem, an electrical issue (like a failed voltage regulator), or a loose connection. Here’s exactly what you need to do to safely and thoroughly troubleshoot and correct this problem in your home or business, whether you’re in St Louis or Nashville.
Fixing the 1903 error involves some basic checks like resetting the control, verifying fuel and breakers, and listening for engine issues. If the error doesn’t clear or returns often, you need a certified generator specialist in St Louis or Nashville to safely assess and repair your equipment, ensuring your property stays powered and protected.
We treat our people as our top priority so they'll treat you the same way. 100% Satisfaction, Every Time!
Providing air conditioning repairs, installation and maintenance for St Louis, MO and Nashville, TN. During the hot summers, call Hoffmann Brothers for all your AC repairs, replacement, and tuneup needs.
Hoffmann Brothers offers residential and commercial electrical services for St Louis homes and businesses. Lighting, outlets, panels, whole house fans, generators, and more. Call our licensed electricians today!
Need a furnace repair in St Louis or Nashville? Hoffmann Brothers can handle all your heating repairs, no matter the brand, including ductless mini-split systems. We also proudly offer heating system installations, and ongoing maintenance services.
Hoffmann Brothers offers appliance repair services throughout St Louis, MO! Our experienced technicians are trained to work on all major brands of most home appliances including Dishwashers, Refrigerators & Freezers, Washing Machines & Dryers, and Ovens.
Hoffmann Brothers is your experienced Plumbing Company service both St Louis and Nashville. We offer plumbing repairs and installations, along with drain and sewer solutions.
Do you need Mechanical or Commercial services for your St Louis or Nashville area business? We offer HVAC, Plumbing, Electrical (St Louis only), Indoor Air Quality, and more.
Hoffmann Brothers is your professional water heater contractors for both Nashville, TN and St Louis, MO. We provide hot water heater installation, repair, and maintenance for both standard and tankless systems.
Hoffmann Brothers is your Nashville and St Louis area drain Plumber. We provide drain cleaning and clearing and much more. Trust our drain experts to fix your clogged sink or toilet quickly and efficiently.
The 1903 error code on a Generac generator signals the generator is having a problem related to "RPM Sense Loss." In simple terms, it means the generator's system can't reliably detect how fast the engine is spinning. This is a critical measurement, since the right engine speed ensures your generator in St Louis or Nashville produces reliable, safe power for your home or business.
A generator converts the motion of its engine (mechanical energy) into electricity. It must turn at a precise speed—measured in revolutions per minute, or RPM—to make the right amount of power. If the system loses track of RPM, it will instantly shut things down to prevent damage.
Many things can cause RPM sense loss on a Generac unit. Here’s a detailed breakdown that applies to many Generac generator models in use throughout St Louis and Nashville:
Generators in St Louis and Nashville often face specific challenges that can lead to the 1903 code. For example, fluctuating weather—humid summers, cold winters, and spring rains—can introduce moisture into outdoor enclosures, causing corrosion or rust on sensor contacts. In neighborhoods and rural areas alike, small animals (mice, squirrels) sometimes chew through wiring, interrupting the RPM signal pathway.
To recap, the main causes behind a 1903 RPM Sense Loss error are:
If you see the 1903 code, this means the generator is unable to accurately sense its engine speed, and it’s shutting down to protect itself and your property. Understanding these root causes can give you a comprehensive idea of what's happening, so you know what’s in play before any professional diagnosis or fix takes place.
SERVING
Brentwood, MO
1025 Hanley Industrial
Brentwood, MO 63144
Nashville, TN
45 Willow St.
Nashville, TN 37210

St Louis Location
(314) 664-3011
St Louis Location
1025 Hanley Industrial Brentwood, MO 63144
Nashville Location
(615) 515-3015
Nashville Location
45 Willow St Nashville, TN 37210
Discover what Kohler Generator Code 21 means, its common causes, and how to fix it. Get quick troubleshooting tips to resolve this error and keep your generator running smoothly.
Discover what Kohler Generator Code 24 means, common causes behind this error, and step-by-step solutions to fix it. Quickly troubleshoot your generator with our expert guide.
Discover what the Kohler Generator "Accy PwrOver Warning" error code means, its common causes, and how to fix it. Get clear, step-by-step solutions to keep your generator running smoothly.
Discover the meaning, common causes, and solutions for the Cummins Generator SPN 175 FMI 3 error code. Learn how to diagnose and fix this issue to keep your generator running smoothly.
Discover what Kohler Generator Code 23 means, common causes behind the error, and effective solutions to fix it. Get your generator running smoothly with these expert tips.
Discover the meaning, common causes, and solutions for Cummins Generator SPN 284 FMI 4 error code. Quickly troubleshoot and resolve this generator issue with our expert guide.