Discover the meaning, common causes, and easy fixes for Generac Generator Error Code 1902. Get your generator running smoothly again with this quick troubleshooting guide.

Head of Content, D. Gorenko
Updated June, 5
When a Generac generator displays the 1902 error code, it means there is a problem known as "Low Oil Pressure Shutdown." Simply put, the generator has detected that the oil pressure inside its engine has dropped below a safe level, so it automatically shuts down to prevent engine damage. This is a safety feature built in by Generac to protect the generator’s engine from running without enough lubrication.
Oil pressure is critical because it keeps moving parts inside the engine lubricated. If the oil pressure is too low, the parts can rub against each other and create heat, friction, and, ultimately, expensive damage. Generators, like the units used in homes and businesses throughout St Louis or Nashville, rely on this oil pressure in the same way as your car’s engine.
This error doesn’t always mean there is something seriously wrong with your generator. Here are the most common reasons:
If you see this code appear during a power outage or on a routine test, follow these steps:
You can help prevent oil pressure shutdowns by:
If you take these steps and understand what this code means, you can reduce surprises and keep your backup power ready for severe weather in both St Louis and Nashville.

Generator issues in St. Louis or Nashville? Our experts provide quick repairs and maintenance to keep you cool. Contact us today!
Request a quote
When your Generac generator displays the “1902 Error,” it means the generator has detected a low battery voltage issue. The generator’s battery is either not holding enough charge or isn’t being charged properly, so the generator’s controller triggers this code to prevent starting or running with insufficient battery power. Without correcting this, your standby power won’t work as intended if there’s an outage.
Your generator relies on a battery, similar to a car, to start up—when the voltage drops too low (below what the system requires, usually under 12 volts), the generator can’t start, and you receive the 1902 error. This could be due to the battery being old, loose or corroded cables, a failed charger, or something drawing current from the battery when it shouldn’t.
If you’ve replaced the battery, confirmed cable connections, checked for power, and still receive a 1902 error, the issue could be with the generator’s internal charging system, a faulty circuit board, or another electrical problem that needs expert diagnosis. For residents and businesses in St Louis (https://www.hoffmannbros.com/) or Nashville (https://www.hoffmannbros.com/nashville/), a skilled technician can safely perform advanced electrical tests, replace system parts, and provide long-term solutions.
We treat our people as our top priority so they'll treat you the same way. 100% Satisfaction, Every Time!
Providing air conditioning repairs, installation and maintenance for St Louis, MO and Nashville, TN. During the hot summers, call Hoffmann Brothers for all your AC repairs, replacement, and tuneup needs.
Hoffmann Brothers offers residential and commercial electrical services for St Louis homes and businesses. Lighting, outlets, panels, whole house fans, generators, and more. Call our licensed electricians today!
Need a furnace repair in St Louis or Nashville? Hoffmann Brothers can handle all your heating repairs, no matter the brand, including ductless mini-split systems. We also proudly offer heating system installations, and ongoing maintenance services.
Hoffmann Brothers offers appliance repair services throughout St Louis, MO! Our experienced technicians are trained to work on all major brands of most home appliances including Dishwashers, Refrigerators & Freezers, Washing Machines & Dryers, and Ovens.
Hoffmann Brothers is your experienced Plumbing Company service both St Louis and Nashville. We offer plumbing repairs and installations, along with drain and sewer solutions.
Do you need Mechanical or Commercial services for your St Louis or Nashville area business? We offer HVAC, Plumbing, Electrical (St Louis only), Indoor Air Quality, and more.
Hoffmann Brothers is your professional water heater contractors for both Nashville, TN and St Louis, MO. We provide hot water heater installation, repair, and maintenance for both standard and tankless systems.
Hoffmann Brothers is your Nashville and St Louis area drain Plumber. We provide drain cleaning and clearing and much more. Trust our drain experts to fix your clogged sink or toilet quickly and efficiently.
When your Generac generator displays a 1902 error code, it means there’s an issue with the generator’s undervoltage sense, specifically on line 1 (L1). In simpler terms, the generator’s monitoring system has detected that the voltage (the force that pushes electricity through the wires) has dropped below a safe or expected level on one part of the system. This error commonly occurs in both residential and commercial settings in areas like St Louis and Nashville because power fluctuations, wiring issues, and environmental factors can affect voltage stability everywhere.
Undervoltage means that the electrical power coming from your generator is less than what it should be. Generators are designed to provide a set voltage, usually about 120 or 240 volts (depending on your needs). If the voltage drops too low, electrical equipment might not work right, can become damaged, or could be unsafe. The 1902 code is the generator’s way of telling you something isn’t right — it’s a built-in safety feature.
There are several reasons a Generac generator in St Louis or Nashville might display a 1902 error code:
In regions with frequent storms, power outages, or older electrical infrastructure, like some neighborhoods in St Louis and Nashville, generators may be more likely to experience fluctuating voltage. Environmental factors like humidity, corrosion, or temperature extremes can also affect generator performance and contribute to the triggers behind the 1902 error code.
The 1902 error code on a Generac generator tells you that your generator is not producing enough voltage on line 1, likely due to issues with the battery, wiring, voltage regulator, internal components, breakers, overload, engine performance, or grounding. These problems can happen anywhere, including in both residential and commercial properties in St Louis and Nashville, and often signal that internal electrical or mechanical checks are needed to make sure your generator runs safely and reliably.
SERVING
Brentwood, MO
1025 Hanley Industrial
Brentwood, MO 63144
Nashville, TN
45 Willow St.
Nashville, TN 37210

St Louis Location
(314) 664-3011
St Louis Location
1025 Hanley Industrial Brentwood, MO 63144
Nashville Location
(615) 515-3015
Nashville Location
45 Willow St Nashville, TN 37210
Discover what Kohler Generator Code 21 means, its common causes, and how to fix it. Get quick troubleshooting tips to resolve this error and keep your generator running smoothly.
Discover what Kohler Generator Code 24 means, common causes behind this error, and step-by-step solutions to fix it. Quickly troubleshoot your generator with our expert guide.
Discover what the Kohler Generator "Accy PwrOver Warning" error code means, its common causes, and how to fix it. Get clear, step-by-step solutions to keep your generator running smoothly.
Discover the meaning, common causes, and solutions for the Cummins Generator SPN 175 FMI 3 error code. Learn how to diagnose and fix this issue to keep your generator running smoothly.
Discover what Kohler Generator Code 23 means, common causes behind the error, and effective solutions to fix it. Get your generator running smoothly with these expert tips.
Discover the meaning, common causes, and solutions for Cummins Generator SPN 284 FMI 4 error code. Quickly troubleshoot and resolve this generator issue with our expert guide.