What does the 1901 error code on Generac a Generator mean?

 

What the 1901 Error Code Means on a Generac Generator

 

When a Generac generator displays the 1901 error code, it means that the generator’s system has detected a loss of communication within critical control components. In simple terms, the generator’s “brain”—the controller—and some of its essential parts are not talking to each other as expected. This typically involves the controller losing contact with modules such as the network or the “Nexus” controller board, which manages the generator’s automated functions.

 

Detailed Explanation of the 1901 Error Code

 

This message isn’t about a physical or mechanical breakdown, but rather an electronic or communication failure. Think of the generator’s control system as similar to a network of computers, where each device must send and receive information. If a cable is unplugged, there’s interference, or a part malfunctions, the system can’t operate safely or reliably—so it sends out an alert like 1901. This ensures the generator won’t accidentally start or run while the internal communication is unreliable.

The 1901 error most often points to these conditions:

  • A wiring harness (the bundle of wires connecting parts) is damaged, unplugged, corroded, or loose, stopping key signals from getting through.
  • The Nexus or main control board has failed or developed issues, disrupting its ability to process information.
  • A low internal backup battery, so the controller can’t keep its memory and settings when not in use.
  • There’s electrical interference, moisture, or corrosion inside the generator’s control panel causing improper connections.
  • A surge after a recent repair, electrical storm, or other electrical event has damaged communication paths on the circuit board.

 

What Should You Do If You See the 1901 Error Code?

 

You should not attempt to operate or reset the generator until the problem is found and fixed, because incorrect communication can prevent the generator from running safely. For residents and businesses in St Louis as well as Nashville, contacting a technician trained in Generac systems is the best option. Hoffman Brothers’ experienced teams in both areas are familiar with this issue and can provide safe diagnostics and repairs.

When a technician arrives, they’ll usually:

  • Visually inspect all visible wiring and connectors for looseness, damage, or corrosion.
  • Run diagnostic tools on the control board to check for failure or interrupted signals.
  • Test the generator’s internal battery and power supply to the control system.
  • Clean or resecure any electrical contacts showing corrosion or debris.
  • If necessary, replace damaged boards, connectors, or wiring harnesses to reestablish proper communication inside the generator.

If the issue is corrosion (which is common in humid environments or after flooding), the technician may need to clean key connections or replace affected parts. In some cases, simply replugging a connector that’s come loose after vibration or a recent service call fixes the error.

 

Why Is This Service Important for Generac Generators in St Louis and Nashville?

 

Generators in both St Louis and Nashville need to be highly reliable due to storms, outages, and extreme weather. The 1901 error prevents the generator from running until the control system’s full communication is restored, which protects your home or business from an unsafe start or operation.

Choosing a local, reputable service provider like Hoffman Brothers ensures your generator will be handled by professionals who know the unique weather and power needs of both cities and have deep experience with Generac systems.

 

Summary and Professional Tips

 

The 1901 error on a Generac generator means vital control parts are not communicating correctly—most often due to wiring issues, board problems, or connector faults. Ignoring the message can risk safety or generator failure during an outage. Prompt, thorough inspection by a certified expert in St Louis or Nashville is the safest way to get your backup power system running again, ensuring you’re protected during storms and unexpected blackouts. Regular preventive maintenance can often detect and prevent these connection issues before they cause a shutdown.

Expert Generator Solutions Await!

Generator issues in St. Louis or Nashville? Our experts provide quick repairs and maintenance to keep you cool. Contact us today!

Request a quote

How to fix the 1901 Error on a Generac Generator?

 

Understanding and Fixing the 1901 Error on a Generac Generator

 

The 1901 error code on a Generac generator means there has been a “Governor Underspeed” issue. In simple terms, your generator’s engine is not running at the required speed to produce electricity safely. If you see this error on your generator in St. Louis or Nashville, here’s exactly what you need to do:

 

Safety First: Ensure Safety Before Inspection

 

Before doing anything, make sure the generator is off and has cooled down. This prevents accidental injury and ensures you don’t come into contact with moving or hot parts. Always turn the main breaker switch on the generator to the “off” position and, if possible, disconnect the battery.

 

Check for Obvious Mechanical Issues

 

Start by checking the outside and inside of your generator for anything unusual:

  • Look for debris like leaves, dirt, or animal nests that may be blocking air flow or moving parts.
  • Listen for any strange noises if the unit recently ran; pops, bangs, or rattles can point to a mechanical problem.
  • Check if any parts look loose, broken, or out of place.

If you’re in climates like St. Louis or Nashville, where critters sometimes get inside outdoor enclosures, this is especially important.

 

Inspect the Air Filter

 

A clogged air filter can cause the engine to “bog down” and trigger the 1901 code.

  • Open the maintenance panel of your generator.
  • Locate the air filter (usually a rectangular or round filter near the engine).
  • If it looks dirty or clogged, replace it with a new one. If you’re not sure whether it’s dirty, replace it anyway—filters are cheap and vital for engine performance.

 

Check Fuel Supply and Fuel Filter

 

An inconsistent fuel supply or a clogged fuel filter can prevent the engine from running at the right speed.

  • If your generator is powered by natural gas, ensure the gas line is open and you have adequate supply. In propane systems, check the tank level and valve positions.
  • Inspect the fuel filter for clogs. If dirty or old, replace the filter.
  • For diesel or gasoline models, also check for stale fuel—old fuel can cause performance issues.

 

Inspect Spark Plugs and Connections

 

Old, dirty, or improperly connected spark plugs can cause engine misfires, which might lead to a 1901 error.

  • Remove the spark plugs (a spark plug wrench is usually needed).
  • Look for signs of wear, soot, or oil on the plugs. Clean them if only slightly dirty, or replace if they appear damaged.
  • Ensure the wires are tightly connected to each spark plug.

 

Check Oil Level and Quality

 

If your oil is old or too low, engine performance will suffer.

  • Remove the oil dipstick, wipe it clean, and reinsert to check the level. If the oil is low, top it off.
  • If the oil looks dark/dirty or hasn’t been changed in a year, do a full oil and oil filter change.

 

Inspect Governor Linkage and Springs

 

The governor is a mechanical system responsible for controlling engine speed. If its parts get stuck or disconnected, you’ll see a 1901 error.

  • Open the generator and look for the governor linkage—a small metal rod or lever linking throttle plate and governor mechanism.
  • Check the springs and rods to ensure they’re not loose, disconnected, or broken.
  • Gently move the linkage to make sure it moves smoothly.

If you don’t feel comfortable with this, specialists serving areas like St. Louis and Nashville recommend a professional inspection.

 

Resetting the Error Code

 

After checking and correcting the above issues, you may need to reset your generator’s control panel. Here’s how:

  • Restore power to the unit and make sure it’s in “OFF” mode.
  • Press “ENTER” (or “RESET,” depending on your model).
  • Hold down the button for several seconds until the error clears from the display.
  • Switch the generator to “AUTO” and try a test run by simulating a power outage or using the “Manual” run button.

If the code returns, it means something else is causing the problem, and further diagnosis is required.

 

When to Call a Professional

 

Some issues require specialized tools or technical knowledge (like governor adjustment or internal fuel system cleaning). If you’ve followed all these steps and the 1901 error persists, or if you aren’t comfortable working inside the generator, it’s time to contact a technician. Homeowners and businesses in St. Louis and Nashville often rely on professional generator teams experienced with Generac models and local safety codes.

 

Regular Maintenance Prevents 1901 Error

 

Finally, to avoid future 1901 errors:

  • Replace air and fuel filters at least annually.
  • Change oil per manufacturer recommendations (often yearly or every 100 hours).
  • Run the generator under load each month to ensure it’s working properly.
  • Schedule yearly full-system maintenance checks, especially before severe seasonal weather.

By understanding these steps and checking these areas, most 1901 errors on a Generac generator in St. Louis or Nashville can be fixed or properly diagnosed for quick service.

Areas Of Expertise

We treat our people as our top priority so they'll treat you the same way. 100% Satisfaction, Every Time!

Air Conditioning

Providing air conditioning repairs, installation and maintenance for St Louis, MO and Nashville, TN. During the hot summers, call Hoffmann Brothers for all your AC repairs, replacement, and tuneup needs.

Electrical Repair

Hoffmann Brothers offers residential and commercial electrical services for St Louis homes and businesses. Lighting, outlets, panels, whole house fans, generators, and more. Call our licensed electricians today!

Heating Services

Need a furnace repair in St Louis or Nashville? Hoffmann Brothers can handle all your heating repairs, no matter the brand, including ductless mini-split systems. We also proudly offer heating system installations, and ongoing maintenance services.

Appliances

Hoffmann Brothers offers appliance repair services throughout St Louis, MO! Our experienced technicians are trained to work on all major brands of most home appliances including Dishwashers, Refrigerators & Freezers, Washing Machines & Dryers, and Ovens.

Plumbing Services

Hoffmann Brothers is your experienced Plumbing Company service both St Louis and Nashville. We offer plumbing repairs and installations, along with drain and sewer solutions.

Commercial Services

Do you need Mechanical or Commercial services for your St Louis or Nashville area business? We offer HVAC, Plumbing, Electrical (St Louis only), Indoor Air Quality, and more.

Water Heaters

Hoffmann Brothers is your professional water heater contractors for both Nashville, TN and St Louis, MO. We provide hot water heater installation, repair, and maintenance for both standard and tankless systems.

Drains & Sewers

Hoffmann Brothers is your Nashville and St Louis area drain Plumber. We provide drain cleaning and clearing and much more. Trust our drain experts to fix your clogged sink or toilet quickly and efficiently.

What could be causing the 1901 error code on a Generac Generator?

 

What Causes the 1901 Error Code on a Generac Generator?

 

When you see the 1901 error code on your Generac generator, it means there’s a communication problem between the generator and its controller. In simple terms, the different parts of your generator aren’t able to “talk” to each other the way they’re supposed to. Without this steady stream of information, the generator may stop running or not start at all, which is something homeowners in St Louis and Nashville especially want to avoid in storm season or during outages.

 

Main Causes of the 1901 Error Code

 

There are several things that can create this breakdown in communication:

  • Loose or Damaged Wiring:\*\* Generac generators rely on wiring and connectors to move signals between the main control board and other important parts. If any wire becomes loose, corroded, chewed by animals, or unplugged—whether inside the generator or leading to external accessories—it disrupts this communication. Humid summers in St Louis or rainy stretches in Nashville can speed up corrosion or affect the integrity of connections.
  • Faulty Controller or Circuit Board: The brain of your Generac generator is an electronic part called the controller or circuit board. If this part itself malfunctions due to age, a manufacturing flaw, or a power surge, it can no longer effectively send or receive commands, leading to the 1901 error.
  • Accessory Communication Failures: Many generators have add-on devices, like remote monitoring modules or automatic transfer switches. If one of these is defective, miswired, or using outdated software, it can interrupt the flow of information and trigger the 1901 code.
  • Electrical Interference: Particularly in urban or busy neighborhoods in St Louis and Nashville, outside sources of electrical “noise” can disturb the generator’s communication signals. Things like lightning strikes, nearby construction, or faulty wiring elsewhere in your building can have an impact.
  • Low or Fluctuating Battery Power: The controller relies on a stable battery supply. If the battery is weak, old, or has dirty terminals, communication can be interrupted, sometimes resulting in a 1901 code.
  • Moisture and Environmental Factors: In climates with plenty of moisture like St Louis and Nashville, water can sneak into the generator’s panels or control box—especially in older units or after severe storms. Water and electricity do not mix, so this can cause short circuits or corrosion invisible to the eye, which interferes with normal operations.
  • Software or Firmware Problems: Just like computers and smartphones, generator controllers run on software (or firmware). If this gets corrupted during an update, or there’s a mismatch between attached modules, the controller can no longer communicate as intended, which shows up as a 1901 code.

 

Why the 1901 Code Matters to Homes and Businesses

 

When you see a 1901 code, it lets you know that something is keeping your generator from receiving or sending key commands. This means your generator may not start when power goes out or might stop running during important moments. In areas like St Louis and Nashville, where storms and outages aren’t uncommon, this could leave your home or business in the dark, impacting comfort and safety for your family or your customers.

 

Summary of What Could Cause the 1901 Code

 

In summary, the 1901 error on a Generac generator is a warning about communication problems between the machine’s key electronic components. This can happen because of loose or corroded wiring, failing electronic parts, weak batteries, moisture buildup, or software glitches. Knowing these sources can help you understand why your generator isn’t working and what issues might need professional attention, particularly in climates like St Louis and Nashville, where reliable backup power is critical.

SERVING

St. Louis & Nashville Areas

Brentwood, MO
1025 Hanley Industrial
Brentwood, MO 63144

Nashville, TN
45 Willow St.
Nashville, TN 37210

Call Our St. Louis Office

Call Our Nashville Office

Nashville Location

(615) 515-3015

Read More

Kohler Generator Code 21 Error Code Explained: Meaning, Causes & Fixes

Discover what Kohler Generator Code 21 means, its common causes, and how to fix it. Get quick troubleshooting tips to resolve this error and keep your generator running smoothly.

Kohler Generator Code 24 Error Code Explained: Meaning, Causes & Fixes

Discover what Kohler Generator Code 24 means, common causes behind this error, and step-by-step solutions to fix it. Quickly troubleshoot your generator with our expert guide.

Kohler Generator Accy PwrOver Warning Error Code Explained: Meaning, Causes & Fixes

Discover what the Kohler Generator "Accy PwrOver Warning" error code means, its common causes, and how to fix it. Get clear, step-by-step solutions to keep your generator running smoothly.

Cummins Generator SPN 175 FMI 3 Error Code Explained: Meaning, Causes & Fixes

Discover the meaning, common causes, and solutions for the Cummins Generator SPN 175 FMI 3 error code. Learn how to diagnose and fix this issue to keep your generator running smoothly.

Kohler Generator Code 23 Error Code Explained: Meaning, Causes & Fixes

Discover what Kohler Generator Code 23 means, common causes behind the error, and effective solutions to fix it. Get your generator running smoothly with these expert tips.

Cummins Generator SPN 284 FMI 4 Error Code Explained: Meaning, Causes & Fixes

Discover the meaning, common causes, and solutions for Cummins Generator SPN 284 FMI 4 error code. Quickly troubleshoot and resolve this generator issue with our expert guide.