A 1800 error code on your Generac generator is a critical warning indicating that the generator has detected a high temperature condition and has shut down to prevent potential damage. In simple terms, this error means your generator got too hot to operate safely, so it turned itself off for protection. High temperatures in generators can quickly lead to major component failures or even fire hazards if continued, so this safeguard is very important for homes and businesses in both St Louis and Nashville, where weather extremes can put extra strain on backup power systems.
When the 1800 error code appears, it is specifically referring to “High Engine Coolant Temperature Shutdown.” To understand this, here’s what happens inside your generator:
When you live or work around St Louis or Nashville, weather fluctuations or seasonal changes can affect your generator. Here are the most common reasons you might see the 1800 code:
If you notice the 1800 code on your generator, follow these steps before retrying operation:
You can avoid most occurrences of high coolant temperature shutdown by following some regular maintenance and usage habits:
By understanding what the Generac 1800 error code means and what you should do, you’re prepared to keep your generator operating safely—protecting your home or business in both St Louis and Nashville. Don’t ignore high temperature warnings: they help you avoid costlier repairs and downtime down the road.

Generator issues in St. Louis or Nashville? Our experts provide quick repairs and maintenance to keep you cool. Contact us today!
Request a quote
When a Generac generator displays the 1800 error code, it means the generator is detecting high line voltage—electricity coming into your home or business that is above the expected safe limit. This is known as “Overvoltage.” Too high voltage can damage connected electrical equipment, so your generator is shutting down or locking out as a safety precaution. Here’s exactly how to fix it and what steps you should follow, whether you’re located in St Louis or Nashville.
This error means your generator senses the line voltage is going above 135 volts (standard is 120V for most homes). It may be caused by:
The main goal is to safely find what’s causing the high voltage and correct it so your generator protects your property, whether you live in St Louis or Nashville.
If the above steps do not resolve the 1800 error, or if you are unsure how to safely check voltage or connections, professional help is essential. High voltage problems can risk both equipment damage and electrical safety hazards. Licensed electricians or generator specialists, such as those serving St Louis and Nashville, have the right tools and expertise to:
For ongoing issues or uncertain situations, contacting a trusted full-service provider in St Louis or Nashville ensures your generator gets repaired safely and your home or business is protected.
To prevent future 1800 overvoltage errors:
By carefully following these steps and seeking professional help where needed, you’ll resolve the 1800 error and keep your Generac generator ready for any power outage.
We treat our people as our top priority so they'll treat you the same way. 100% Satisfaction, Every Time!
Providing air conditioning repairs, installation and maintenance for St Louis, MO and Nashville, TN. During the hot summers, call Hoffmann Brothers for all your AC repairs, replacement, and tuneup needs.
Hoffmann Brothers offers residential and commercial electrical services for St Louis homes and businesses. Lighting, outlets, panels, whole house fans, generators, and more. Call our licensed electricians today!
Need a furnace repair in St Louis or Nashville? Hoffmann Brothers can handle all your heating repairs, no matter the brand, including ductless mini-split systems. We also proudly offer heating system installations, and ongoing maintenance services.
Hoffmann Brothers offers appliance repair services throughout St Louis, MO! Our experienced technicians are trained to work on all major brands of most home appliances including Dishwashers, Refrigerators & Freezers, Washing Machines & Dryers, and Ovens.
Hoffmann Brothers is your experienced Plumbing Company service both St Louis and Nashville. We offer plumbing repairs and installations, along with drain and sewer solutions.
Do you need Mechanical or Commercial services for your St Louis or Nashville area business? We offer HVAC, Plumbing, Electrical (St Louis only), Indoor Air Quality, and more.
Hoffmann Brothers is your professional water heater contractors for both Nashville, TN and St Louis, MO. We provide hot water heater installation, repair, and maintenance for both standard and tankless systems.
Hoffmann Brothers is your Nashville and St Louis area drain Plumber. We provide drain cleaning and clearing and much more. Trust our drain experts to fix your clogged sink or toilet quickly and efficiently.
When you see the 1800 error code on your Generac generator, it specifically indicates there is an "Undervoltage" issue detected during operation. "Undervoltage" means the electricity your generator is trying to create has dropped below the normal range. In simpler terms, the machine isn’t producing enough voltage, which can stop it from powering your home or building properly. Residents and business owners in St Louis and Nashville often experience this error because of several underlying causes, all related to either the generator itself or issues coming from the outside power source.
There are a few main reasons why a Generac generator might show the 1800 error code, and understanding these will give you a clear picture of what’s happening inside the machine.
You might notice this code show up right as the generator starts, or at moments when it is powering heavier equipment. It can also appear after a major storm, cold snap, or if your generator hasn’t been exercised in a long time—a common issue in regions like St Louis and Nashville where seasonal shifts can change how often generators are used.
If you see the 1800 error code, your generator is trying to protect itself and your property from damage caused by low voltage—which can harm sensitive electronics or cause flickering and unreliable power. Even if you aren’t using your generator often, noticing this error signals there’s a problem that will eventually prevent the generator from working when you need it.
Understanding these causes can help you discuss the problem knowledgeably with a technician in St Louis or Nashville, ensuring your home or business always has reliable backup power.
SERVING
Brentwood, MO
1025 Hanley Industrial
Brentwood, MO 63144
Nashville, TN
45 Willow St.
Nashville, TN 37210

St Louis Location
(314) 664-3011
St Louis Location
1025 Hanley Industrial Brentwood, MO 63144
Nashville Location
(615) 515-3015
Nashville Location
45 Willow St Nashville, TN 37210
Discover what Kohler Generator Code 21 means, its common causes, and how to fix it. Get quick troubleshooting tips to resolve this error and keep your generator running smoothly.
Discover what Kohler Generator Code 24 means, common causes behind this error, and step-by-step solutions to fix it. Quickly troubleshoot your generator with our expert guide.
Discover what the Kohler Generator "Accy PwrOver Warning" error code means, its common causes, and how to fix it. Get clear, step-by-step solutions to keep your generator running smoothly.
Discover the meaning, common causes, and solutions for the Cummins Generator SPN 175 FMI 3 error code. Learn how to diagnose and fix this issue to keep your generator running smoothly.
Discover what Kohler Generator Code 23 means, common causes behind the error, and effective solutions to fix it. Get your generator running smoothly with these expert tips.
Discover the meaning, common causes, and solutions for Cummins Generator SPN 284 FMI 4 error code. Quickly troubleshoot and resolve this generator issue with our expert guide.