Discover what Generac Generator 1600 error code means, common causes, and step-by-step fixes. Get your generator running smoothly with this troubleshooting guide.

Head of Content, D. Gorenko
Updated June, 5
When your Generac generator displays a 1600 error code, it’s alerting you to a “Under Frequency Lockout/Fault.” In the simplest terms, this means the generator’s engine—or the electrical system it is powering—is not producing electricity at the right frequency, which is usually set at 60 Hertz (Hz) for households and most businesses in areas like St Louis and Nashville. Frequency is a measure of how many cycles per second the electricity is alternating—think of it as the "heartbeat" of your electrical system.
A normal, healthy generator keeps that frequency very steady. If it drops too low, the generator can’t safely power your home or business, so the system will shut itself down to prevent damage, showing you the 1600 error.
The 1600 fault appears when the generator's output frequency falls significantly below what it should be, usually due to the engine running too slowly. Common reasons include:
If you encounter a 1600 code, these steps can help you understand and sometimes resolve the issue:
If the 1600 error does not go away after these simple checks, it is time to call in a professional. More in-depth repairs, like adjusting the governor, replacing sensors, or repairing engine parts, require specialized tools and knowledge. If you live in areas such as St Louis or Nashville, finding a full-service generator technician with experience in residential and commercial units ensures your generator receives proper troubleshooting and certified repairs.
Preventing the 1600 error—and many other issues—starts with regular maintenance. Annual servicing includes changing filters, oil, spark plugs, and testing the system under load. In cities like St Louis and Nashville, experienced teams can help keep your generator ready for storms, outages, and emergencies throughout all seasons.
By understanding what the 1600 error means and knowing what steps to take, you can keep your Generac generator running reliably and know when to reach out for help if basic troubleshooting doesn’t resolve the problem.

Generator issues in St. Louis or Nashville? Our experts provide quick repairs and maintenance to keep you cool. Contact us today!
Request a quote
When a Generac generator displays a 1600 Error, it means the controller is not communicating with the engine control board (also called the ESM or ECM). In other words, the "brain" that tells your generator when to turn on and off is not able to talk with the part that operates the engine. This breakdown in communication can prevent your generator from starting or functioning correctly—leaving your home or business without backup power.
If you’re in St Louis or Nashville and facing this issue, here’s a very thorough and user-friendly step-by-step approach so you can confidently handle the 1600 Error, or know when to call a professional.
Before touching your generator, always follow basic safety precautions:
Sometimes the error is a temporary glitch:
If the code returns, continue with the troubleshooting steps below.
Loose or corroded wiring can cause the 1600 Error. Here’s how to check:
If the error remains, the problem may be internal and more complex.
A weak battery or blown fuse is sometimes the culprit:
Small animals sometimes chew wiring, and weather can make things worse:
If all basic steps fail, the 1600 Error usually means a deeper fault in the circuit boards or wiring that needs professional-level tools. Certified generator technicians in St Louis and Nashville use special software and tester cables to diagnose “communication loss” between the controller and engine board. Advanced troubleshooting can include:
Generators have safety locks to prevent damage to the engine or your home’s wiring, which is why they shut down with this error.
In summary, fixing the 1600 Error on your Generac generator in St Louis or Nashville starts with a simple reset, moves to checking connections and battery, and finishes with a detailed inspection for wiring or board faults. If basic steps fail and the generator remains down, it’s time to call an expert—many repairs on these systems require technical skill or access to replacement circuit boards.
Catching the 1600 Error early and acting promptly can often save you from longer-term outages and future problems. If you find yourself unsure or uncomfortable at any point, for your safety and the reliability of your backup power, contact an experienced technician.
We treat our people as our top priority so they'll treat you the same way. 100% Satisfaction, Every Time!
Providing air conditioning repairs, installation and maintenance for St Louis, MO and Nashville, TN. During the hot summers, call Hoffmann Brothers for all your AC repairs, replacement, and tuneup needs.
Hoffmann Brothers offers residential and commercial electrical services for St Louis homes and businesses. Lighting, outlets, panels, whole house fans, generators, and more. Call our licensed electricians today!
Need a furnace repair in St Louis or Nashville? Hoffmann Brothers can handle all your heating repairs, no matter the brand, including ductless mini-split systems. We also proudly offer heating system installations, and ongoing maintenance services.
Hoffmann Brothers offers appliance repair services throughout St Louis, MO! Our experienced technicians are trained to work on all major brands of most home appliances including Dishwashers, Refrigerators & Freezers, Washing Machines & Dryers, and Ovens.
Hoffmann Brothers is your experienced Plumbing Company service both St Louis and Nashville. We offer plumbing repairs and installations, along with drain and sewer solutions.
Do you need Mechanical or Commercial services for your St Louis or Nashville area business? We offer HVAC, Plumbing, Electrical (St Louis only), Indoor Air Quality, and more.
Hoffmann Brothers is your professional water heater contractors for both Nashville, TN and St Louis, MO. We provide hot water heater installation, repair, and maintenance for both standard and tankless systems.
Hoffmann Brothers is your Nashville and St Louis area drain Plumber. We provide drain cleaning and clearing and much more. Trust our drain experts to fix your clogged sink or toilet quickly and efficiently.
When you see the 1600 error code on a Generac generator, it means there is a problem with the controller — specifically, it can’t communicate with the main control board, or there’s a loss of connection between other important components inside your generator. In simpler words, the brain of your generator is having trouble talking to the rest of the machine. This issue is sometimes called a "Loss of Communication" error. It can happen in both home and business generators, which is why homeowners and facility managers across St Louis and Nashville need to know what might trigger it.
There are several typical reasons this code can show up on Generac generators—whether you have a model in St Louis or Nashville:
This error often shows up right when you try to start or test your generator, or sometimes it appears while the generator is running. The generator's internal monitor is always checking for communication between its main parts. If it can’t "hear back" from a crucial piece—even just for a moment—the 1600 code will appear on your generator’s screen. This is a built-in safety feature. It warns you that your generator isn’t getting the information it needs to run safely or at full performance.
Ignoring this error can mean your generator won’t work when you need it most—like during storms or power failures. A communication loss may also signal hidden electrical or electronic trouble that might make the issue worse over time. Prompt attention is especially important for those living or working in areas like St Louis and Nashville, where reliable backup power is crucial for comfort and safety.
In summary, the 1600 error code mostly means there’s a problem with information traveling between the main control board and other essential parts of your Generac generator. The most common causes are loose, corroded, or disconnected wiring, a failed control board, accessory malfunctions, software glitches, or power-related disturbances. This error needs attention to ensure your generator will work reliably for you—whether you live in St Louis, Nashville, or anywhere else where backup power is important.
SERVING
Brentwood, MO
1025 Hanley Industrial
Brentwood, MO 63144
Nashville, TN
45 Willow St.
Nashville, TN 37210

St Louis Location
(314) 664-3011
St Louis Location
1025 Hanley Industrial Brentwood, MO 63144
Nashville Location
(615) 515-3015
Nashville Location
45 Willow St Nashville, TN 37210
Discover what Kohler Generator Code 21 means, its common causes, and how to fix it. Get quick troubleshooting tips to resolve this error and keep your generator running smoothly.
Discover what Kohler Generator Code 24 means, common causes behind this error, and step-by-step solutions to fix it. Quickly troubleshoot your generator with our expert guide.
Discover what the Kohler Generator "Accy PwrOver Warning" error code means, its common causes, and how to fix it. Get clear, step-by-step solutions to keep your generator running smoothly.
Discover the meaning, common causes, and solutions for the Cummins Generator SPN 175 FMI 3 error code. Learn how to diagnose and fix this issue to keep your generator running smoothly.
Discover what Kohler Generator Code 23 means, common causes behind the error, and effective solutions to fix it. Get your generator running smoothly with these expert tips.
Discover the meaning, common causes, and solutions for Cummins Generator SPN 284 FMI 4 error code. Quickly troubleshoot and resolve this generator issue with our expert guide.