Discover what the Generac Generator 1511 error code means, its common causes, and effective solutions. Get your generator running smoothly again with this quick troubleshooting guide.

Head of Content, D. Gorenko
Updated June, 5
The 1511 error code on a Generac generator signals that there is an issue with the generator’s low speed sense—or, in simpler terms, the unit thinks it’s not running at the speed it is supposed to. This error is technically named “RPM Sense Loss,” and it happens when the generator’s controller detects that the engine either failed to reach, or maintain, the designated operating speed within the expected timeframe after starting. This speed is vital because generators are designed to run at a specific revolutions-per-minute (RPM) to produce steady and safe electricity for your home or business in St Louis and Nashville.
Most often, the 1511 code shows up when something goes wrong in the startup or running process. Common causes include:
These problems can strike both residential and business properties, whether in the hot summers of Nashville or the cold winters of St Louis.
Here’s what you should do if you see this code:
If after these checks the 1511 code remains, it’s safest to contact professionals with experience in generator repair who serve the St Louis and Nashville regions. Specialized technicians can run deeper diagnostics, inspect fuel systems, ignition, and perform safe electronic tests to pinpoint the problem.
Leaving this code unresolved means your Generac generator will not work during a power outage. This leaves your home or business in St Louis or Nashville vulnerable to loss of power, which can affect refrigerators, heating/cooling systems, security systems, medical devices, and computer networks. Regular generator maintenance is essential: professionals recommend at least yearly check-ups, especially before severe weather season, to prevent these kinds of errors from occurring when you need the generator most.
The best way to avoid running into 1511 errors is through routine maintenance, like regularly checking the battery, ensuring fresh fuel supply, changing air filters, and occasionally running your generator through its test cycle. In St Louis and Nashville, weather can be tough on generators, so it’s smart to look for signs of corrosion, leaks, or rodent nests, and to schedule professional inspections before storm or freeze seasons.
With proper attention, your Generac generator will be ready whenever you need reliable backup power, keeping daily life or business running smoothly no matter the circumstances.

Generator issues in St. Louis or Nashville? Our experts provide quick repairs and maintenance to keep you cool. Contact us today!
Request a quote
The 1511 error on a Generac generator indicates a problem with the “RPM Sense Loss.” This error means your generator’s controller isn’t getting the correct feedback from the engine’s speed sensor—so it doesn’t know if the engine is running at the right speed or even running at all. This can stop the generator from operating or transferring power to your home or business in St Louis or Nashville.
Even if it seems unrelated, start with basic checks. The generator might show this error simply because it could not start due to an empty propane/natural gas supply or a weak battery. Make sure:
The controller needs to be cleared of error codes before you can try starting the generator:
A common cause of the 1511 error in both St Louis and Nashville is a wiring issue or a bad RPM sensor (often called a crankshaft position sensor or magnetic pickup). Check:
Switch the controller to “Manual” and attempt to start the generator while carefully watching (and listening) to the engine and control panel:
If everything else checks out, the RPM sensor itself may be the issue. If you have a digital multimeter and feel comfortable:
Rarely, a faulty generator control board or electronic governor can cause phantom RPM sense errors. If you have already checked battery, fuel, and the RPM sensor, but the 1511 code remains, you may need an advanced diagnostic. In such cases, it’s best to contact a licensed technician with experience in your local area—particularly since Generac warranty or parts availability can differ between St Louis and Nashville.
For stubborn 1511 errors, or if these checks seem intimidating, reach out to an experienced generator service provider familiar with both local codes and weather conditions in St Louis and Nashville. A technician can quickly pinpoint issues and safely replace parts, ensuring your standby power is reliable before the next outage.
We treat our people as our top priority so they'll treat you the same way. 100% Satisfaction, Every Time!
Providing air conditioning repairs, installation and maintenance for St Louis, MO and Nashville, TN. During the hot summers, call Hoffmann Brothers for all your AC repairs, replacement, and tuneup needs.
Hoffmann Brothers offers residential and commercial electrical services for St Louis homes and businesses. Lighting, outlets, panels, whole house fans, generators, and more. Call our licensed electricians today!
Need a furnace repair in St Louis or Nashville? Hoffmann Brothers can handle all your heating repairs, no matter the brand, including ductless mini-split systems. We also proudly offer heating system installations, and ongoing maintenance services.
Hoffmann Brothers offers appliance repair services throughout St Louis, MO! Our experienced technicians are trained to work on all major brands of most home appliances including Dishwashers, Refrigerators & Freezers, Washing Machines & Dryers, and Ovens.
Hoffmann Brothers is your experienced Plumbing Company service both St Louis and Nashville. We offer plumbing repairs and installations, along with drain and sewer solutions.
Do you need Mechanical or Commercial services for your St Louis or Nashville area business? We offer HVAC, Plumbing, Electrical (St Louis only), Indoor Air Quality, and more.
Hoffmann Brothers is your professional water heater contractors for both Nashville, TN and St Louis, MO. We provide hot water heater installation, repair, and maintenance for both standard and tankless systems.
Hoffmann Brothers is your Nashville and St Louis area drain Plumber. We provide drain cleaning and clearing and much more. Trust our drain experts to fix your clogged sink or toilet quickly and efficiently.
When a Generac generator displays the 1511 error code, it means the generator’s controller has detected an "RPM Sense Loss" during the startup sequence. In simple terms, this code is telling you that the generator’s engine was supposed to start running, but the internal system couldn’t confirm the engine is actually turning at the correct speed (RPM stands for "revolutions per minute," a way to measure how fast an engine spins).
The generator uses sensors to monitor how fast the engine is spinning. When you turn on your Generac generator, these sensors check that everything is moving at the correct speed. If the sensor can't detect that the engine has started and reached the proper RPM, the 1511 code will appear. This helps protect the generator from damage, as running at incorrect speeds can cause problems inside the machine.
Several factors, both simple and complex, can cause the 1511 error code. Here are the main possibilities:
Local climate can also play a role. In St Louis, for example, the temperature swings between hot summers and freezing winters can affect battery life and fuel lines. In Nashville, fluctuating humidity and summer storms can introduce moisture or cause corrosion on electrical components. Both urban and rural settings might see differences in pest activity around wiring, especially in outdoor generator installations.
To sum up, the 1511 error means your generator is unable to pick up the engine’s proper spinning speed when attempting to start. The root cause can range from common things like a weak battery or bad fuel supply, to more technical issues like faulty sensors, wiring issues, or even larger engine problems. Location and local environmental factors—whether you’re in St Louis or Nashville—can influence what’s most likely causing the trouble. Understanding these causes is the first step in getting your generator back to keeping your home or business powered during an outage.
SERVING
Brentwood, MO
1025 Hanley Industrial
Brentwood, MO 63144
Nashville, TN
45 Willow St.
Nashville, TN 37210

St Louis Location
(314) 664-3011
St Louis Location
1025 Hanley Industrial Brentwood, MO 63144
Nashville Location
(615) 515-3015
Nashville Location
45 Willow St Nashville, TN 37210
Discover what Kohler Generator Code 21 means, its common causes, and how to fix it. Get quick troubleshooting tips to resolve this error and keep your generator running smoothly.
Discover what Kohler Generator Code 24 means, common causes behind this error, and step-by-step solutions to fix it. Quickly troubleshoot your generator with our expert guide.
Discover what the Kohler Generator "Accy PwrOver Warning" error code means, its common causes, and how to fix it. Get clear, step-by-step solutions to keep your generator running smoothly.
Discover the meaning, common causes, and solutions for the Cummins Generator SPN 175 FMI 3 error code. Learn how to diagnose and fix this issue to keep your generator running smoothly.
Discover what Kohler Generator Code 23 means, common causes behind the error, and effective solutions to fix it. Get your generator running smoothly with these expert tips.
Discover the meaning, common causes, and solutions for Cummins Generator SPN 284 FMI 4 error code. Quickly troubleshoot and resolve this generator issue with our expert guide.