Discover the meaning, common causes, and solutions for Generac Generator error code 1400. Learn how to quickly diagnose and fix this issue to keep your generator running smoothly.

Head of Content, D. Gorenko
Updated June, 5
When a Generac generator displays the 1400 error code, it means that the unit has detected a trouble with its 'Undervoltage Sense.' In simple terms, the generator's control system is not seeing the right amount of voltage coming from the generator’s main power line during its operation or a test run. The generator expects a normal voltage (usually around 120/240 volts for most homes and businesses in cities like St. Louis and Nashville). If this voltage drops below a safe level quickly, or never reaches that level at all, the control board triggers a 1400 code to prevent damage or unsafe operation.
Undervoltage is when electrical power being produced is lower than required. If your generator is running but producing too little voltage, it can harm your electronics and appliances, and can also indicate a deeper mechanical or electrical problem inside the generator. That's why the 1400 code is important—it’s your generator’s way of alerting you to a potentially unsafe condition, just like a check engine light in a car.
A few common reasons why the 1400 code might occur on a Generac generator in St. Louis or Nashville include:
If you see a 1400 code, here’s how the typical process works:
Absolutely. Regular maintenance is the most important step in avoiding issues like the 1400 error code. Here’s how you can help protect your investment:
Ignoring a 1400 error can lead to more costly breakdowns or even dangerous conditions. Problems like this don’t just fix themselves, especially with complex electrical components. That’s why it’s always best to get expert help from specialists familiar with local electrical codes and conditions in places like St. Louis and Nashville.
In summary, the 1400 error code on a Generac generator is an alert about too little voltage being produced, often due to electrical or mechanical faults, and it is a warning to prevent bigger issues. Understanding, identifying, and quickly fixing the root cause keeps your home or business safe, and your power running reliably when you need it most.

Generator issues in St. Louis or Nashville? Our experts provide quick repairs and maintenance to keep you cool. Contact us today!
Request a quote
A 1400 error on a Generac generator usually means there’s an issue with “Under Frequency.” In simple terms, it’s saying the generator isn’t running at the correct speed to provide the right type of electricity. The generator is supposed to turn at a specific number of rotations per minute (RPM) to give out stable power for your home or business, whether you’re in St Louis or Nashville. If the engine speed drops below normal, you’ll get that 1400 code—and your generator may shut down or not deliver the power you need. Here’s what you should do, step by step, if you see this error:
If your generator is not getting enough fuel, it can’t run at full speed:
If the engine can’t get enough air, it’ll slow down:
If your generator is powering too many appliances or large equipment, it can cause the RPMs to drop:
Sometimes vibrations loosen the wires that feed critical sensors:
If you’ve completed the above steps and the 1400 error still shows, the problem could be with one of the following:
For these types of problems, contact a licensed generator technician with experience servicing Generac units. In St Louis and Nashville, professional specialists who work on both residential and commercial generators every day can diagnose and repair these advanced issues safely and quickly.
Fixing a 1400 error on your Generac generator often involves checking fuel, air, electrical load, maintenance items, and basic wiring. If the issue is still unresolved after these steps, it’s time to call in a trusted local generator specialist in St Louis or Nashville to ensure your backup power stays reliable and safe when you need it most.
We treat our people as our top priority so they'll treat you the same way. 100% Satisfaction, Every Time!
Providing air conditioning repairs, installation and maintenance for St Louis, MO and Nashville, TN. During the hot summers, call Hoffmann Brothers for all your AC repairs, replacement, and tuneup needs.
Hoffmann Brothers offers residential and commercial electrical services for St Louis homes and businesses. Lighting, outlets, panels, whole house fans, generators, and more. Call our licensed electricians today!
Need a furnace repair in St Louis or Nashville? Hoffmann Brothers can handle all your heating repairs, no matter the brand, including ductless mini-split systems. We also proudly offer heating system installations, and ongoing maintenance services.
Hoffmann Brothers offers appliance repair services throughout St Louis, MO! Our experienced technicians are trained to work on all major brands of most home appliances including Dishwashers, Refrigerators & Freezers, Washing Machines & Dryers, and Ovens.
Hoffmann Brothers is your experienced Plumbing Company service both St Louis and Nashville. We offer plumbing repairs and installations, along with drain and sewer solutions.
Do you need Mechanical or Commercial services for your St Louis or Nashville area business? We offer HVAC, Plumbing, Electrical (St Louis only), Indoor Air Quality, and more.
Hoffmann Brothers is your professional water heater contractors for both Nashville, TN and St Louis, MO. We provide hot water heater installation, repair, and maintenance for both standard and tankless systems.
Hoffmann Brothers is your Nashville and St Louis area drain Plumber. We provide drain cleaning and clearing and much more. Trust our drain experts to fix your clogged sink or toilet quickly and efficiently.
When a Generac generator displays the 1400 error code, it typically means there is a problem with the generator’s under-frequency protection. In simpler words, it’s alerting you that the engine is running at a speed below its normal range. This may lead to the generator not producing enough electricity to power your home or business, or may cause inconsistent power delivery. The control system inside the generator monitors the speed, and when it detects that the engine is spinning too slowly, it triggers the 1400 error code to let you know something isn’t right.
Generators like those used in St Louis and Nashville create power by spinning an engine at a set speed. In the United States, that speed is usually 3600 RPM (revolutions per minute), which creates electricity at a standard frequency of 60 Hertz (Hz). If the engine slows down—even just a bit—the frequency drops below 60 Hz. This low frequency, or "under-frequency," can potentially damage sensitive appliances or lead to power instability, which is why the generator sends out the 1400 code as an alert.
There are several reasons you might see the 1400 code on your Generac generator, whether you’re in St Louis with frequent weather swings, or dealing with outages in Nashville. These reasons include:
When the 1400 error code is present, the generator may shut down automatically or continue running with a warning, depending on the severity of the problem. Automatic shutdown is a safety feature, helping to avoid damage to both the generator and the appliances in your building. Older or sensitive devices, especially in homes or businesses across St Louis and Nashville, can be harmed by unstable electrical frequencies.
By understanding what the 1400 error code means, and recognizing the different possible causes, owners in St Louis and Nashville can better prepare for safe and reliable generator operation year-round.
SERVING
Brentwood, MO
1025 Hanley Industrial
Brentwood, MO 63144
Nashville, TN
45 Willow St.
Nashville, TN 37210

St Louis Location
(314) 664-3011
St Louis Location
1025 Hanley Industrial Brentwood, MO 63144
Nashville Location
(615) 515-3015
Nashville Location
45 Willow St Nashville, TN 37210
Discover what Kohler Generator Code 21 means, its common causes, and how to fix it. Get quick troubleshooting tips to resolve this error and keep your generator running smoothly.
Discover what Kohler Generator Code 24 means, common causes behind this error, and step-by-step solutions to fix it. Quickly troubleshoot your generator with our expert guide.
Discover what the Kohler Generator "Accy PwrOver Warning" error code means, its common causes, and how to fix it. Get clear, step-by-step solutions to keep your generator running smoothly.
Discover the meaning, common causes, and solutions for the Cummins Generator SPN 175 FMI 3 error code. Learn how to diagnose and fix this issue to keep your generator running smoothly.
Discover what Kohler Generator Code 23 means, common causes behind the error, and effective solutions to fix it. Get your generator running smoothly with these expert tips.
Discover the meaning, common causes, and solutions for Cummins Generator SPN 284 FMI 4 error code. Quickly troubleshoot and resolve this generator issue with our expert guide.