What does the 1205 error code on Generac a Generator mean?

 

What the 1205 Error Code on a Generac Generator Means

 

If your Generac generator is showing the 1205 error code, it means the generator has detected that it is running out of fuel—specifically, it’s giving a “Low Fuel – Add Fuel” warning. This code is common on home standby and commercial generators that run on liquid propane (LP) or diesel. When you see the 1205 error, the generator is telling you it cannot start or continue to run properly because its internal sensors picked up that the fuel level is too low to operate safely.

 

Why the 1205 Error Code Happens on Generac Generators

 

There are a few main causes for the 1205 code:

  • Your fuel tank is nearly empty, so there’s not enough propane or diesel for the generator’s engine to work correctly.
  • There’s a problem with the sensor that measures the fuel level—it could be disconnected, broken, or malfunctioning, which leads the generator to think there’s not enough fuel even if the tank is full.
  • There might be a blockage or restriction in the fuel line, so the engine isn’t actually getting enough fuel even though there is some in the tank.

If you live in areas such as St Louis or Nashville, weather—like extreme cold—can occasionally make fuel issues worse, especially with propane systems.

 

What to Do When You See the 1205 “Low Fuel” Error Code

 

  • First, check your fuel supply. If it’s a propane tank, look at the gauge (usually on top or the side of the tank) to make sure you have enough fuel (most systems work best when the tank is more than 25% full). For diesel, visually inspect or use a dipstick to see the fuel level.
  • If the tank is low, arrange for a refill from your fuel supplier. In busy areas like St Louis and Nashville, scheduling refills during peak outage seasons will help you avoid running out.
  • If the tank is full but the generator still shows 1205, you may have a problem with the fuel level sensor or a clogged fuel line. In this case, it’s best to contact a trained generator technician to inspect the system.
  • After refilling or fixing any issues, don’t forget to clear the error code—usually by pressing the “Off” button, waiting 30 seconds, then switching the generator back to “Auto.”

 

Why a 1205 Code is a Serious Warning

 

The 1205 code isn’t just an annoying alert. Running a generator with low fuel can damage the engine, cause it to stop unexpectedly during an outage, or introduce harmful air into the fuel lines. It can also keep your St Louis or Nashville home or business without backup power right when it’s needed most.

 

Preventing Future 1205 Generator Errors

 

  • Regularly check your fuel levels, especially before severe weather arrives.
  • Have your generator serviced routinely by professionals, who will test the sensors and perform safety checks.
  • Keep records of last maintenance and fuel deliveries to anticipate refills before fuel runs out.

If you ever feel unsure handling your generator or fuel system, call an experienced technician. In cities like St Louis and Nashville, local experts are trained for these exact problems and can keep your generator running safely and reliably through every season.

Expert Generator Solutions Await!

Generator issues in St. Louis or Nashville? Our experts provide quick repairs and maintenance to keep you cool. Contact us today!

Request a quote

How to fix the 1205 Error on a Generac Generator?

 

What the 1205 Error Means on a Generac Generator and How to Fix It

 

When you see a 1205 error on your Generac generator, it means the generator’s controller is detecting a low oil pressure condition – in simple words, your generator’s engine isn’t sensing enough lubricating oil pressure while it’s trying to run or exercise. This trigger protects your generator from engine damage and automatically stops it from running. Whether you live in St Louis or Nashville, this is a common problem that requires quick attention to avoid engine damage.

 

Ensuring Safety First

 

Before you do anything, make sure the generator is completely turned off. Set it to the OFF position using the control switch. If you recently ran or tested your generator, allow it to cool down before touching any engine parts to avoid burns. Remove any jewelry or loose clothing, and keep all pets and children away from the area.

 

Checking Oil Levels and Condition

 

  • Open the generator’s access panel by unscrewing or unlatching as needed.
  • Locate the yellow oil dipstick – usually on the engine’s side. Pull the dipstick out, clean it with a rag, reinsert it fully, then pull it out again and look at the oil level marking.
  • If the oil is below the "FULL" line, top it off using the recommended oil type in your owner’s manual. Most Generac models use 5W-30 full synthetic oil, but always check your specific manual.
  • Examine the oil’s condition – if it’s black, gritty, watery, or smells burned, change the oil and oil filter before proceeding.

 

Resetting the 1205 Error Code

 

Once you have confirmed the oil level is correct and the oil condition is good, you’ll need to clear the error code:

  • Turn the generator’s controller switch to the “OFF” position and wait for about 30 seconds.
  • Turn the controller switch to “ON”, then to “AUTO.”
  • The generator should cycle through its startup – look at the control panel, and the error code should be gone. If you still see the 1205 code, try resetting one more time after double-checking the oil.

 

If the 1205 Error Persists

 

If you topped off the oil and correctly reset the controller, and the 1205 error still stays on the screen, it usually means there is a mechanical or sensor problem:

  • The oil pressure sensor may be faulty or disconnected. This is an electronic part that “feels” the oil pressure. If it’s defective, the generator thinks there isn’t enough oil even if the level is correct.
  • There may be a wiring or connector issue to the oil sensor.
  • Rarely, the internal oil pump or engine could have an actual problem causing no oil pressure, especially if you previously ran the generator with low oil accidentally.

 

When to Call a Professional

 

If restarting, topping off the oil, and resetting don’t solve the problem after one or two tries, do not keep trying to run your generator. Continuous low oil pressure running can cause engine damage that’s costly to fix.
In both St Louis and Nashville, licensed full-service companies like Hoffman Brothers have trained technicians who specialize in residential and commercial generator repairs, including diagnosing and replacing faulty oil pressure sensors, fixing wiring, or performing deeper engine repairs when necessary.

 

How to Prevent the 1205 Error in the Future

 

  • Check and top off your generator’s oil every month, or before every storm season in St Louis and Nashville.
  • Change the oil and oil filter at least once a year or after every 100 hours of use.
  • Schedule annual maintenance with a professional generator service technician who can check the entire lubrication and sensor system.
  • Look for any oil leaks under or inside the generator housing regularly, so you can catch problems before they trigger the 1205 error.

By following these steps, you’ll address the immediate 1205 error code, protect your generator’s engine, and keep your standby power ready and reliable. If there’s ever any doubt, trusted local experts in St Louis and Nashville are available to help.

Areas Of Expertise

We treat our people as our top priority so they'll treat you the same way. 100% Satisfaction, Every Time!

Air Conditioning

Providing air conditioning repairs, installation and maintenance for St Louis, MO and Nashville, TN. During the hot summers, call Hoffmann Brothers for all your AC repairs, replacement, and tuneup needs.

Electrical Repair

Hoffmann Brothers offers residential and commercial electrical services for St Louis homes and businesses. Lighting, outlets, panels, whole house fans, generators, and more. Call our licensed electricians today!

Heating Services

Need a furnace repair in St Louis or Nashville? Hoffmann Brothers can handle all your heating repairs, no matter the brand, including ductless mini-split systems. We also proudly offer heating system installations, and ongoing maintenance services.

Appliances

Hoffmann Brothers offers appliance repair services throughout St Louis, MO! Our experienced technicians are trained to work on all major brands of most home appliances including Dishwashers, Refrigerators & Freezers, Washing Machines & Dryers, and Ovens.

Plumbing Services

Hoffmann Brothers is your experienced Plumbing Company service both St Louis and Nashville. We offer plumbing repairs and installations, along with drain and sewer solutions.

Commercial Services

Do you need Mechanical or Commercial services for your St Louis or Nashville area business? We offer HVAC, Plumbing, Electrical (St Louis only), Indoor Air Quality, and more.

Water Heaters

Hoffmann Brothers is your professional water heater contractors for both Nashville, TN and St Louis, MO. We provide hot water heater installation, repair, and maintenance for both standard and tankless systems.

Drains & Sewers

Hoffmann Brothers is your Nashville and St Louis area drain Plumber. We provide drain cleaning and clearing and much more. Trust our drain experts to fix your clogged sink or toilet quickly and efficiently.

What could be causing the 1205 error code on a Generac Generator?

 

Understanding What Causes the 1205 Error Code on a Generac Generator

 

The 1205 error code on a Generac generator indicates the generator has experienced an "Under-Speed" condition. This means the engine is not running at the proper speed it should be. A generator needs to maintain a specific speed to produce electricity at the right frequency and voltage. When it runs slower than required, it's called under-speed, and the generator's control board detects this and triggers the 1205 error to prevent damage or unsafe power output.

 

What Does "Under-Speed" Mean and Why Is It a Problem?

 

Generators are designed to operate at a set speed—typically 3600 revolutions per minute (RPM) for most residential and smaller commercial models. This precise speed is necessary for the generator to produce electricity that matches the frequency your home or business needs (in the United States, that's 60 Hz). If the generator drops below this speed, the appliances connected to it could be damaged, or the power could become unreliable. To protect both the equipment and everything connected to it, Generac designed the generator to shut down and show error code 1205 when it detects under-speed.

 

Main Causes Behind the 1205 Error Code

 

Several specific issues can lead to an under-speed condition on your Generac generator in areas like St Louis or Nashville:

  • Fuel Problems: The most common cause is that the generator isn't getting enough fuel. This could happen if the propane or natural gas supply is low, shut off, or obstructed by a clog in the line. Even running generators in cold weather in St Louis or Nashville can cause regulators or fuel lines to freeze, restricting fuel flow. Bad fuel (old gasoline in dual-fuel models) or contaminated fuel can also cause stalling or slow engine speeds.
  • Mechanical or Engine Issues: Worn-out parts such as spark plugs, dirty air filters, fuel filters, or blocked carburetors will prevent the engine from getting the air and fuel mixture it needs, which slows the generator down. Oil that’s too old or too low in quantity can also make it harder for the engine to run at the right speed.
  • Heavy Electrical Load: If you try to power too many devices or appliances at once, the generator may slow down as it struggles to supply enough power. This extra demand can trigger the 1205 code if the engine can't maintain its set speed under the strain.
  • Problems with the Governor: The governor is a device that regulates the engine speed in the generator. If it malfunctions, sticks, or comes disconnected, it can't keep the engine at the correct RPM. This is a less common issue, but still possible, especially with older units or those exposed to a lot of dirt and moisture.
  • Sensor or Control Board Issues: Occasionally, the problem isn’t with the engine at all, but with the sensors that monitor engine speed or the electronic control board that interprets those signals. A faulty sensor might mistakenly think the engine is running slow and trigger the 1205 error.

 

Conditions in St Louis and Nashville That Can Affect Your Generator

 

Environmental factors common in both St Louis and Nashville—such as rapid weather changes, moisture, and winter temperatures—can make fuel delivery problems more likely, especially with propane tanks or exposed gas lines. Dirt and pollen (which tend to be high in the spring and fall in these cities) can also clog air filters faster, particularly if your generator runs regularly or sits near landscaping.

 

Summary of the 1205 Error Code Causes

 

When you see the 1205 code on your Generac generator, it's always related to the engine not running fast enough, and it's a safety feature to protect your home or business equipment. The main causes almost always relate to fuel delivery problems, mechanical maintenance issues, heavy or improper loading, governor malfunctions, or issues with the speed-detecting sensors. Paying attention to how environmental factors in regions like St Louis or Nashville can affect generators will help in identifying and preventing the root causes of this error.

SERVING

St. Louis & Nashville Areas

Brentwood, MO
1025 Hanley Industrial
Brentwood, MO 63144

Nashville, TN
45 Willow St.
Nashville, TN 37210

Call Our St. Louis Office

Call Our Nashville Office

Nashville Location

(615) 515-3015

Read More

Kohler Generator Code 21 Error Code Explained: Meaning, Causes & Fixes

Discover what Kohler Generator Code 21 means, its common causes, and how to fix it. Get quick troubleshooting tips to resolve this error and keep your generator running smoothly.

Kohler Generator Code 24 Error Code Explained: Meaning, Causes & Fixes

Discover what Kohler Generator Code 24 means, common causes behind this error, and step-by-step solutions to fix it. Quickly troubleshoot your generator with our expert guide.

Kohler Generator Accy PwrOver Warning Error Code Explained: Meaning, Causes & Fixes

Discover what the Kohler Generator "Accy PwrOver Warning" error code means, its common causes, and how to fix it. Get clear, step-by-step solutions to keep your generator running smoothly.

Cummins Generator SPN 175 FMI 3 Error Code Explained: Meaning, Causes & Fixes

Discover the meaning, common causes, and solutions for the Cummins Generator SPN 175 FMI 3 error code. Learn how to diagnose and fix this issue to keep your generator running smoothly.

Kohler Generator Code 23 Error Code Explained: Meaning, Causes & Fixes

Discover what Kohler Generator Code 23 means, common causes behind the error, and effective solutions to fix it. Get your generator running smoothly with these expert tips.

Cummins Generator SPN 284 FMI 4 Error Code Explained: Meaning, Causes & Fixes

Discover the meaning, common causes, and solutions for Cummins Generator SPN 284 FMI 4 error code. Quickly troubleshoot and resolve this generator issue with our expert guide.