Discover what Generac Generator 1204 error code means, its common causes, and easy fixes. Keep your generator running smoothly with our expert troubleshooting guide.

Head of Content, D. Gorenko
Updated June, 5
When your Generac generator displays the 1204 error code, it is signaling an 'Overcrank' condition. This means the generator attempted to start several times but did not succeed. In everyday terms, "overcranking" is like trying to start your car, but the engine just keeps turning over and doesn't fire up. For homeowners and business owners in St Louis and Nashville, understanding this error can help you prevent stress and even costly repairs by knowing what to look for and when to call for help.
This error occurs during the generator’s automatic starting sequence, usually when there’s a loss of utility power or during a scheduled exercise run. If the generator fails to start after a set number of attempts (often three to five), it stops trying to protect itself and displays the 1204 code. The reason your generator can’t start could be due to:
Those living or working in climates with seasonal temperature swings—like St Louis’s chilly winters or Nashville’s hot summers—can see these problems more often if regular maintenance is not performed.
If your Generac generator shows the 1204 code, try these actions before calling a professional:
If the generator still won’t start, do not keep cranking it, as this can further damage key components. Now is the time to contact experienced technicians, especially for residents of St Louis and Nashville who rely on reliable emergency power.
To avoid facing the overcrank (1204) error in the future, consider professional annual or semi-annual maintenance. This includes:
In both St Louis and Nashville, these maintenance routines help reduce emergency service calls and ensure generators start when needed most.
The Generac 1204 error code is an 'Overcrank' alert, meaning your generator tried and failed multiple times to start. Common causes include fuel supply issues, battery problems, ignition troubles, and clogged filters. Check these areas yourself, clear the fault if possible, but don’t hesitate to call a trusted service technician in St Louis or Nashville if the generator won’t cooperate. Staying proactive with care and inspection can help you avoid this code in the future and keep your power on when you need it most.

Generator issues in St. Louis or Nashville? Our experts provide quick repairs and maintenance to keep you cool. Contact us today!
Request a quote
The 1204 error on a Generac generator indicates a problem with the generator’s service schedule or maintenance interval. This error typically means the generator’s controller thinks it is overdue for routine maintenance—specifically, it is related to “Code 1204 – Maintenance Due.” The generator will still usually run with this error, but it’s an important reminder that servicing is needed to keep it reliable for your home or business in St Louis or Nashville.
Maintenance due means the generator’s controller is alerting you that a regularly scheduled service—like changing the oil, replacing filters, or checking the battery—has not been completed within the recommended time or runtime hours. Generac generators track runtime and calendar days to let you know when servicing is needed, usually after every 200 hours of use or yearly, depending on the model.
If you have any trouble performing maintenance, accessing the control panel, or if the code won’t clear after following these steps, it’s a good idea to contact a local generator specialist. In both St Louis and Nashville, many families and businesses trust experts for thorough inspection, proper servicing, and code resolution.
Consistently performing and recording generator maintenance is the best way to prevent the 1204 error from reappearing and to ensure your backup power is ready to go when you need it—whether you’re in St Louis or Nashville. Always prioritize safety—if you are unsure about even one step, reach out to a local professional who can help.
We treat our people as our top priority so they'll treat you the same way. 100% Satisfaction, Every Time!
Providing air conditioning repairs, installation and maintenance for St Louis, MO and Nashville, TN. During the hot summers, call Hoffmann Brothers for all your AC repairs, replacement, and tuneup needs.
Hoffmann Brothers offers residential and commercial electrical services for St Louis homes and businesses. Lighting, outlets, panels, whole house fans, generators, and more. Call our licensed electricians today!
Need a furnace repair in St Louis or Nashville? Hoffmann Brothers can handle all your heating repairs, no matter the brand, including ductless mini-split systems. We also proudly offer heating system installations, and ongoing maintenance services.
Hoffmann Brothers offers appliance repair services throughout St Louis, MO! Our experienced technicians are trained to work on all major brands of most home appliances including Dishwashers, Refrigerators & Freezers, Washing Machines & Dryers, and Ovens.
Hoffmann Brothers is your experienced Plumbing Company service both St Louis and Nashville. We offer plumbing repairs and installations, along with drain and sewer solutions.
Do you need Mechanical or Commercial services for your St Louis or Nashville area business? We offer HVAC, Plumbing, Electrical (St Louis only), Indoor Air Quality, and more.
Hoffmann Brothers is your professional water heater contractors for both Nashville, TN and St Louis, MO. We provide hot water heater installation, repair, and maintenance for both standard and tankless systems.
Hoffmann Brothers is your Nashville and St Louis area drain Plumber. We provide drain cleaning and clearing and much more. Trust our drain experts to fix your clogged sink or toilet quickly and efficiently.
The 1204 error code on a Generac generator is specifically related to a "Low Voltage" or "Low Battery Voltage" alert. This means the generator is detecting that the battery, which is essential for starting and running the generator, does not have enough power or voltage to operate correctly. This issue prevents your generator from starting up automatically when you need it most, which is especially concerning for people in areas like St Louis and Nashville who might face storms or outages.
A generator’s battery functions much like a car’s battery – it provides the electrical power to start the engine. If the battery voltage drops too low, the engine cannot turn over. With newer Generac models, the generator regularly "checks" itself. When it senses this low voltage, it creates the 1204 error code and may display a "Low Battery" warning light or message on its control panel. For both home and business owners in St Louis and Nashville, being aware of what causes voltage loss is important for dependable backup power.
There are several reasons why the 1204 code appears, all involving the battery or its supporting systems:
Generac generators are equipped with a control panel or display module. As part of its routine "exercise cycle" – usually a weekly automatic self-test where the generator starts up briefly to check systems – the control panel reads the battery voltage. If the reading is below what the manufacturer considers safe (generally under 12.4 volts for a 12V system), it creates the 1204 error code. This error is logged in the generator’s memory and often triggers a warning light or an alert on the display panel.
In many residential and commercial buildings throughout St Louis and Nashville, it’s common for owners to see this code especially after a period of bad weather, extreme temperature swings, or following a long dormant period where the generator hasn’t run.
When you see a 1204 error, your Generac generator may not start automatically if the power goes out or an emergency arises. This means your home or business could be left without backup power until the underlying battery voltage issue is resolved.
Understanding the specific causes—and recognizing that environmental factors in both St Louis and Nashville can play a large role—prepares you as a generator owner to know why it happens, what’s at risk, and lets you explain the situation fully to your service provider if you need help.
SERVING
Brentwood, MO
1025 Hanley Industrial
Brentwood, MO 63144
Nashville, TN
45 Willow St.
Nashville, TN 37210

St Louis Location
(314) 664-3011
St Louis Location
1025 Hanley Industrial Brentwood, MO 63144
Nashville Location
(615) 515-3015
Nashville Location
45 Willow St Nashville, TN 37210
Discover what Kohler Generator Code 21 means, its common causes, and how to fix it. Get quick troubleshooting tips to resolve this error and keep your generator running smoothly.
Discover what Kohler Generator Code 24 means, common causes behind this error, and step-by-step solutions to fix it. Quickly troubleshoot your generator with our expert guide.
Discover what the Kohler Generator "Accy PwrOver Warning" error code means, its common causes, and how to fix it. Get clear, step-by-step solutions to keep your generator running smoothly.
Discover the meaning, common causes, and solutions for the Cummins Generator SPN 175 FMI 3 error code. Learn how to diagnose and fix this issue to keep your generator running smoothly.
Discover what Kohler Generator Code 23 means, common causes behind the error, and effective solutions to fix it. Get your generator running smoothly with these expert tips.
Discover the meaning, common causes, and solutions for Cummins Generator SPN 284 FMI 4 error code. Quickly troubleshoot and resolve this generator issue with our expert guide.