Discover what Generac Generator 1202 error code means, its common causes, and how to fix it quickly. Learn troubleshooting tips to get your generator running smoothly again.

Head of Content, D. Gorenko
Updated June, 5
If your Generac generator is showing the 1202 error code, it means your generator has detected a “Low Oil Pressure Shutdown.” This is a safety feature that instantly stops the generator’s engine to prevent damage when it senses that the oil pressure is too low for safe operation. In simple terms: your generator stopped running to protect itself because it doesn’t have enough oil pressure.
Oil pressure is vital in any engine, including those in standby and backup generators like Generac models commonly found in both St Louis and Nashville homes and businesses. Oil lubricates the moving parts inside the engine, reducing friction and preventing the motor from overheating. Without proper oil pressure, metal components would rub directly against each other, causing fast and severe engine damage—sometimes within minutes.
The 1202 code is programmed to keep your generator safe. When sensors register that oil pressure has dropped below a critical threshold, the control panel shuts the generator down and displays this error. This can prevent catastrophic damages, such as a seized engine, which are much more expensive to repair than anything causing a 1202 error.
There are a few common reasons you might see the 1202 code on your Generac generator in St Louis or Nashville:
Regular generator maintenance is the best way to prevent the 1202 error. Both St Louis and Nashville experience temperature extremes—cold winters can make oil thicken, and hot summers can degrade oil faster. Seasonal oil and filter changes, as well as regular full-system inspections, will keep your equipment working properly and reduce the risk of seeing low oil pressure shutdown codes during critical times.
If you’re unable to resolve the 1202 code with the steps above, or if you’re uncomfortable checking oil and troubleshooting, contact a local generator service expert. In both St Louis and Nashville, it’s not uncommon for these issues to be quickly resolved by professionals, minimizing downtime and protecting the investment you’ve made in backup power for your home or business.
To recap, the 1202 error is your Generac generator’s way of telling you it needs immediate attention due to low oil pressure. In most cases, it’s caused by low oil level, dirty oil, or a leak, but other mechanical or electrical faults can be to blame. Addressing this issue fast will keep your generator running when you need it most, which is especially important for families and businesses in both St Louis and Nashville who depend on reliable backup power.

Generator issues in St. Louis or Nashville? Our experts provide quick repairs and maintenance to keep you cool. Contact us today!
Request a quote
When your Generac generator displays the 1202 error code, it means there is a "Low Oil Pressure Shutdown." This safety feature automatically turns off the generator engine to prevent it from running when the oil pressure is dangerously low, protecting the engine from severe damage. In the areas of St Louis and Nashville, homeowners and businesses rely on standby generators especially during severe weather, and this error is one of the more common service calls.
This error may be triggered by:
If you have checked and corrected the oil, inspected for leaks, and looked over basic connections but the problem continues, it’s time to consult a certified technician. Generator engines are sensitive machines, and it’s much less expensive to fix a minor part now than to replace an engine later. Residents and businesses across St Louis and Nashville know that prompt, knowledgeable service keeps your generator ready and reliable in any emergency.
We treat our people as our top priority so they'll treat you the same way. 100% Satisfaction, Every Time!
Providing air conditioning repairs, installation and maintenance for St Louis, MO and Nashville, TN. During the hot summers, call Hoffmann Brothers for all your AC repairs, replacement, and tuneup needs.
Hoffmann Brothers offers residential and commercial electrical services for St Louis homes and businesses. Lighting, outlets, panels, whole house fans, generators, and more. Call our licensed electricians today!
Need a furnace repair in St Louis or Nashville? Hoffmann Brothers can handle all your heating repairs, no matter the brand, including ductless mini-split systems. We also proudly offer heating system installations, and ongoing maintenance services.
Hoffmann Brothers offers appliance repair services throughout St Louis, MO! Our experienced technicians are trained to work on all major brands of most home appliances including Dishwashers, Refrigerators & Freezers, Washing Machines & Dryers, and Ovens.
Hoffmann Brothers is your experienced Plumbing Company service both St Louis and Nashville. We offer plumbing repairs and installations, along with drain and sewer solutions.
Do you need Mechanical or Commercial services for your St Louis or Nashville area business? We offer HVAC, Plumbing, Electrical (St Louis only), Indoor Air Quality, and more.
Hoffmann Brothers is your professional water heater contractors for both Nashville, TN and St Louis, MO. We provide hot water heater installation, repair, and maintenance for both standard and tankless systems.
Hoffmann Brothers is your Nashville and St Louis area drain Plumber. We provide drain cleaning and clearing and much more. Trust our drain experts to fix your clogged sink or toilet quickly and efficiently.
The 1202 error code on a Generac generator points to a “Low Oil Pressure Shutdown.” In very simple terms, this means your generator’s engine has detected that the oil pressure is too low for safe operation, so the system shuts down to protect itself from serious damage. Every engine, including those in backup generators across both St Louis and Nashville areas, depends on oil to keep its internal parts lubricated, reduce friction, and help with cooling. Without enough oil pressure, moving parts can grind together, overheat, and cause permanent damage. That’s why the generator’s safety system watches oil pressure very closely and shuts down right away if something’s wrong.
The 1202 error is specific, but the causes behind it can be varied. Here’s what could trigger it:
Modern Generac generators, whether installed in homes or businesses from St Louis to Nashville, use an oil pressure sensor that “reads” how hard the oil is being pushed around the engine. If this level falls below a certain safe point—even for a moment—the generator tells its controller to shut things down and displays the 1202 error code. This system is designed to prevent catastrophic engine damage, acting like a watchdog so you don’t risk expensive repairs or a failed backup system when you need it most.
The 1202 error code is always about not enough oil pressure inside your Generac generator’s engine. That can happen because there isn’t enough oil, the oil is dirty or contaminated, the oil pump or the sensor isn’t working right, or there are internal engine problems. For property owners across St Louis and Nashville, paying attention to oil levels, the kind of oil used, and regular maintenance are the best ways to prevent these causes. Knowing what this code means and what might cause it helps you work with professionals quickly and ensures your standby power stays ready when you need it.
SERVING
Brentwood, MO
1025 Hanley Industrial
Brentwood, MO 63144
Nashville, TN
45 Willow St.
Nashville, TN 37210

St Louis Location
(314) 664-3011
St Louis Location
1025 Hanley Industrial Brentwood, MO 63144
Nashville Location
(615) 515-3015
Nashville Location
45 Willow St Nashville, TN 37210
Discover what Kohler Generator Code 21 means, its common causes, and how to fix it. Get quick troubleshooting tips to resolve this error and keep your generator running smoothly.
Discover what Kohler Generator Code 24 means, common causes behind this error, and step-by-step solutions to fix it. Quickly troubleshoot your generator with our expert guide.
Discover what the Kohler Generator "Accy PwrOver Warning" error code means, its common causes, and how to fix it. Get clear, step-by-step solutions to keep your generator running smoothly.
Discover the meaning, common causes, and solutions for the Cummins Generator SPN 175 FMI 3 error code. Learn how to diagnose and fix this issue to keep your generator running smoothly.
Discover what Kohler Generator Code 23 means, common causes behind the error, and effective solutions to fix it. Get your generator running smoothly with these expert tips.
Discover the meaning, common causes, and solutions for Cummins Generator SPN 284 FMI 4 error code. Quickly troubleshoot and resolve this generator issue with our expert guide.