What does the 1201 error code on Generac a Generator mean?

 

What the 1201 Error Code Means on a Generac Generator

 

When you see the 1201 error code on your Generac generator, it means that one of the generator’s cylinders is not firing properly. More specifically, this code signals what’s known as a “Loss of Engine Speed Sensing,” or in simple terms, the engine isn't running at the speed it should because the ignition is not happening on all cylinders. Generators use engines that are similar to car engines, and when all parts aren’t working correctly, this error code appears and may shut the generator down or prevent it from starting. This can happen to generators in homes, businesses, or critical facilities in both St Louis and Nashville.

 

Causes of the 1201 Error Code

 

Many people in St Louis and Nashville call professionals after seeing this error, and here’s what usually causes it:

  • Faulty Ignition Coil: The ignition coil is a component that supplies a high voltage spark to ignite the fuel in the cylinder. If a coil fails, that cylinder doesn’t fire.
  • Bad Spark Plug: The spark plug is what actually creates the spark. If it's old, dirty, or broken, it may not produce the spark needed for combustion.
  • Wiring Issues: Sometimes, the wires running to the ignition coil or spark plug become loose, corroded, or damaged.
  • Fuel Delivery Problems: If there is a problem with the fuel (incorrect pressure, clog, or bad fuel injector), it won’t burn in the cylinder.
  • ECU (Engine Control Unit) Malfunction: This is the brain of the generator that senses how fast the engine is running. If it can't read the engine speed or detect one cylinder not working, it triggers the 1201 code.

 

Common Symptoms When the 1201 Error Appears

 

You might experience these situations with your Generac generator in St Louis or Nashville when the 1201 code is active:

  • The generator won’t start.
  • If it does start, it runs roughly or makes unusual noises.
  • It shuts down quickly after starting, sometimes with engine warning lights or beeping.
  • You may smell unburned fuel or see smoke from the exhaust.

 

What To Do If You See Error Code 1201

 

If you’re in St Louis or Nashville and spot this error on your Generac generator:

  • Check the Basic Settings: Ensure the generator has enough fuel, and that the battery is charged. Sometimes, simple things can trigger an error.
  • Inspect Visible Connections: If you’re comfortable, take a look at the spark plugs and wiring for signs of damage or loose fittings, but don’t attempt repairs if you’re unsure.
  • Reset the Generator: Try turning it off and then back on to see if the code clears. If it returns, the problem is ongoing.
  • Avoid Repeated Starts: Don’t repeatedly try to run the generator, as this could cause more damage.
  • Call a Professional: This error often requires diagnostic tools and technical knowledge. Qualified technicians, like those serving St Louis and Nashville, can safely check and repair ignition coils, spark plugs, and electronic components.

 

Preventing the 1201 Error Code

 

Routine maintenance is the best method to prevent the 1201 error:

  • Have regular professional inspections, at least once a year, especially before storm season in St Louis and Nashville.
  • Replace spark plugs and ignition coils at the manufacturer’s recommended intervals.
  • Use clean, fresh fuel and keep the fuel system clean.
  • Address any odd noises, loss of power, or frequent starts/stops promptly before the error occurs.

 

Why Fast Attention Is Important

 

Ignoring the 1201 error code increases the risk of further engine damage and long outages, which can be especially problematic during adverse weather or power emergencies in places like St Louis and Nashville. Quick action ensures your generator is ready when you need it most.

 

Expert Generator Solutions Await!

Generator issues in St. Louis or Nashville? Our experts provide quick repairs and maintenance to keep you cool. Contact us today!

Request a quote

How to fix the 1201 Error on a Generac Generator?

 

What Causes Generac Generator 1201 Error and How to Fix It

 

The 1201 error code on a Generac generator signals a problem with the "Choke Not Opening" during the start-up process. The choke is a mechanical part that helps start the engine by restricting airflow, which makes it easier for the engine to fire up, especially when it's cold outside in places like St. Louis or Nashville. When the 1201 error appears, your generator might not start at all, or it could have difficulty running reliably.

 

Step-by-Step Solution for 1201 Error on Generac Generators

 

  • Understand the 1201 Error and Why It Matters
    The error means the control board tried to start the engine but detected that the choke wasn't moving to the "open" position after startup. This keeps the engine from getting the air it needs and can cause it to flood or stall.
  • Turn Off Generator and Ensure Safety
    Before you begin, always turn off your generator using the control panel. Disconnect the main breaker to avoid any risk of electrical shock or accidental starting. If it's safe, shut off fuel supply as well.
  • Check the Choke Linkage for Obstructions
    Locate the choke assembly on your Generac generator — usually found near the carburetor. Look for dirt, rodents’ nests, ice (especially common during St. Louis winters), or debris around the choke arm or linkage that may prevent it from moving. Carefully clear away any obstruction with a soft brush or cloth.
  • Inspect the Choke Solenoid and Linkage Movement
    Ask a helper to turn the generator to "Auto" while you watch the choke mechanism. You should see the arm move when trying to start. If it doesn't budge, the electric choke solenoid may have failed, the linkage may be bent, or a connector may be loose. Gently wiggle the linkage to check for tightness or binding.
  • Check Wiring and Electrical Connectors
    Look for loose or unplugged wires near the choke or the control board. Moisture, rodents, or vibration in climates like Nashville can dislodge connectors over time. Ensure all connections are tight and free of corrosion. If wires are damaged, they may need repair or replacement.
  • Test the Choke Solenoid
    The solenoid is the electrical part that moves the choke arm. If you have a multimeter, disconnect power from the generator and measure the resistance of the solenoid. It should not be completely open (infinite resistance) or zero (shorted). Replace it if it doesn’t show continuity, as this means the solenoid has failed.
  • Inspect for Damaged Control Board (Advanced)
    If everything else checks out but the choke still won’t move, the issue could be a failed control board — the computer that sends signals to the choke solenoid. This is rare but possible after power surges or lightning common in St. Louis and Nashville. If replacing the solenoid and fixing wiring doesn't help, consider professional diagnosis.
  • Clear the Error Code and Test Generator
    Once you’ve addressed the mechanical or electrical issue, press "Enter" or "Off" on your generator’s control panel to clear the error. Switch the unit back to "Auto" and either let it perform its normal exercise or manually initiate a test run. Watch for the choke to operate smoothly and confirm that the 1201 error does not return.

 

When to Call a Professional

 

If you’re uncomfortable with any of these checks, or if the problem persists even after ensuring the choke moves freely and all electrical connections are intact, contact a trained generator technician. Both St. Louis and Nashville residents can rely on local experts familiar with Generac systems and climate-specific concerns for thorough repair and annual maintenance.

 

Preventing Future 1201 Errors

 

  • Keep your generator area clean and clear of leaves, rodents, or snow that could block moving parts.
  • Make sure scheduled maintenance includes choke lubrication and linkage checks, particularly before severe weather seasons hit St. Louis or Nashville.
  • Check battery and electrical system for moisture or corrosion following severe storms.

By following these steps, most 1201 errors on Generac generators can be quickly addressed, helping to ensure reliable start-up and safe operation throughout the year.

Areas Of Expertise

We treat our people as our top priority so they'll treat you the same way. 100% Satisfaction, Every Time!

Air Conditioning

Providing air conditioning repairs, installation and maintenance for St Louis, MO and Nashville, TN. During the hot summers, call Hoffmann Brothers for all your AC repairs, replacement, and tuneup needs.

Electrical Repair

Hoffmann Brothers offers residential and commercial electrical services for St Louis homes and businesses. Lighting, outlets, panels, whole house fans, generators, and more. Call our licensed electricians today!

Heating Services

Need a furnace repair in St Louis or Nashville? Hoffmann Brothers can handle all your heating repairs, no matter the brand, including ductless mini-split systems. We also proudly offer heating system installations, and ongoing maintenance services.

Appliances

Hoffmann Brothers offers appliance repair services throughout St Louis, MO! Our experienced technicians are trained to work on all major brands of most home appliances including Dishwashers, Refrigerators & Freezers, Washing Machines & Dryers, and Ovens.

Plumbing Services

Hoffmann Brothers is your experienced Plumbing Company service both St Louis and Nashville. We offer plumbing repairs and installations, along with drain and sewer solutions.

Commercial Services

Do you need Mechanical or Commercial services for your St Louis or Nashville area business? We offer HVAC, Plumbing, Electrical (St Louis only), Indoor Air Quality, and more.

Water Heaters

Hoffmann Brothers is your professional water heater contractors for both Nashville, TN and St Louis, MO. We provide hot water heater installation, repair, and maintenance for both standard and tankless systems.

Drains & Sewers

Hoffmann Brothers is your Nashville and St Louis area drain Plumber. We provide drain cleaning and clearing and much more. Trust our drain experts to fix your clogged sink or toilet quickly and efficiently.

What could be causing the 1201 error code on a Generac Generator?

 

Understanding the Generac Generator 1201 Error Code

 

The 1201 error code on a Generac generator is related to the generator’s "RPM sense loss." In simple words, it means the generator’s control system cannot detect the engine speed properly—it’s not registering how fast the engine is spinning. This is a safety feature built into your unit to prevent engine damage. If your Generac generator in St Louis or Nashville is throwing the 1201 error, it’s because something is stopping it from correctly recognizing or achieving the right RPMs (revolutions per minute).

 

What is "RPM Sense Loss" and Why is it Important?

 

Generators need to know exactly how fast their engines are running. If the engine speed is too slow, too fast, or not detectable at all, the generator can’t safely produce electricity. That’s why it monitors RPMs through a tiny signal wire or sensor, which feeds information to the unit’s computer. If this system fails in any way, you'll see code 1201.

 

Common Causes of the 1201 Error Code

 

This issue can happen for several reasons, including:

  • Battery Issues: If the battery is weak or dead, the starter can struggle to turn the engine fast enough. A slow crank can confuse the computer into thinking the engine isn’t running at all, even if it's trying to start.
  • Faulty or Dirty Spark Plugs: Spark plugs ignite the fuel-air mixture. If they’re dirty, worn, or disconnected, the generator engine may not start, causing loss of signal.
  • Problems with the RPM Sensor or Wire: There’s a wire or sensor responsible for detecting RPM. If this connection is loose, corroded, broken, or damaged by rodents or weather conditions (which can be common in St Louis and Nashville), the generator won’t "see" the engine speed and will show 1201.
  • Fuel Problems: If your generator is low on fuel, if the fuel line is clogged, or if old, stale gas is used, the engine might not start properly. That means there’s not enough activity for the RPM sensor to detect.
  • Air Filter Blockage: If the air filter is dirty or blocked, it can prevent the engine from getting enough air to run, which leads to difficulty starting and can cause this error.
  • Starter Motor Problems: Sometimes the starter motor is weak or failing, so the engine won’t spin fast enough, resulting in incorrect or no RPM signal.
  • Control Board Malfunctions: The onboard computer—called the control board—in rare cases can fail to process the RPM signal, especially after lightning strikes or severe power surges (sometimes seen in areas with frequent storms like Nashville or St Louis).
  • Loose or Corroded Connections: Generators vibrate as they operate. Over time, wires and plugs can become loose, especially after harsh Midwest winters in St Louis or humid summers in Nashville. Corroded terminals or loose nuts/bolts at the control panel or starter circuit can disrupt the RPM sensor signal.
  • Incorrect Oil Level: Some Generac generators may refuse to start if the oil is too low, which can also trigger related error codes.
  • Wrong Installation or Environment: If the generator is installed in an area that is too damp, dusty, or otherwise outside recommended installation practices (seen sometimes in both St Louis and Nashville), connectors and sensors can degrade faster, leading to signal loss.

 

When Does the 1201 Error Happen?

 

This error usually pops up right after the generator tries to start. You may hear it attempt a few cranks, maybe a sputter, then it shuts off and displays 1201. Sometimes the generator may run for a few seconds and then stop, depending on how intermittent or severe the loss of signal is.

 

What Happens if the 1201 Error is Ignored?

 

Without fixing the root cause of the 1201 code, your Generac generator in St Louis or Nashville won’t be able to kick in during an outage. That means no backup power just when you need it most, leaving your home or business at risk for lost refrigeration, HVAC, or other critical systems.

 

Key Points to Remember about the 1201 Error on Generac Generators

 

  • It’s a signal that the electronic control system cannot “see” engine speed correctly—a problem with engine detection, not just a random glitch.
  • Most causes are related to starting difficulties, wiring, sensors, or basic maintenance items.
  • This error can happen in both new and old generators, often due to environmental factors specific to St Louis or Nashville homes and businesses, like local weather, pest problems, or wear and tear.

By understanding what the 1201 error code means, you can better describe the issue when contacting a professional or scheduling an inspection, ensuring a smoother and faster resolution for your Generac generator issues.

SERVING

St. Louis & Nashville Areas

Brentwood, MO
1025 Hanley Industrial
Brentwood, MO 63144

Nashville, TN
45 Willow St.
Nashville, TN 37210

Call Our St. Louis Office

Call Our Nashville Office

Nashville Location

(615) 515-3015

Read More

Kohler Generator Code 21 Error Code Explained: Meaning, Causes & Fixes

Discover what Kohler Generator Code 21 means, its common causes, and how to fix it. Get quick troubleshooting tips to resolve this error and keep your generator running smoothly.

Kohler Generator Code 24 Error Code Explained: Meaning, Causes & Fixes

Discover what Kohler Generator Code 24 means, common causes behind this error, and step-by-step solutions to fix it. Quickly troubleshoot your generator with our expert guide.

Kohler Generator Accy PwrOver Warning Error Code Explained: Meaning, Causes & Fixes

Discover what the Kohler Generator "Accy PwrOver Warning" error code means, its common causes, and how to fix it. Get clear, step-by-step solutions to keep your generator running smoothly.

Cummins Generator SPN 175 FMI 3 Error Code Explained: Meaning, Causes & Fixes

Discover the meaning, common causes, and solutions for the Cummins Generator SPN 175 FMI 3 error code. Learn how to diagnose and fix this issue to keep your generator running smoothly.

Kohler Generator Code 23 Error Code Explained: Meaning, Causes & Fixes

Discover what Kohler Generator Code 23 means, common causes behind the error, and effective solutions to fix it. Get your generator running smoothly with these expert tips.

Cummins Generator SPN 284 FMI 4 Error Code Explained: Meaning, Causes & Fixes

Discover the meaning, common causes, and solutions for Cummins Generator SPN 284 FMI 4 error code. Quickly troubleshoot and resolve this generator issue with our expert guide.